Information:
Illustration 1 g00678674This diagnostic code is recorded when the VIMS electronic control module reads the voltage of the SPI data link and the voltage is above normal. Test Step 1. CHECK THE DISPLAY MODULES.
Disconnect the display modules from the machine harness one at a time and reconnect the display modules from the machine harness one at a time.
Check whether the diagnostic code CID 0819 FMI 03 is present. Expected Result:The diagnostic code CID 0819 FMI 03 remains active.Results:
OK - The diagnostic code has not changed. Diagnostic code CID 0819 FMI 03 remains active. Repeat this process for each module. Proceed to test step 2.
NOT OK - The diagnostic code is no longer active. Replace the display module. STOPTest Step 2. CHECK FOR SHORT TO +BATTERY
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness connectors J1 and J2 from the VIMS electronic control module and disconnect the machine harness from the display modules.
At the machine harness connectors J1 and J2 for the VIMS electronic control module, measure the resistance between the +battery contact J1-1 and connector contacts J2-10, J2-20 and J2- 28. Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to test step 3.
NOT OK - The resistance is less than 5000 ohms. The machine harness has failed. The SPI data link is shorted to the +battery circuit.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK FOR OPEN HARNESS
The disconnect switch remains in the OFF position and the key start switch remains in the OFF position.
All modules remain disconnected from the machine harness.
Measure the resistance of the SPI data link circuits in the machine harness. Measure the resistance from the connector of the VIMS electronic control module to the connector for each of the display modules. Expected Result:The resistance measures less than 5 ohms.Results:
OK - The resistance measures less than 5 ohms. The SPI data link circuit in the machine harness is correct. The VIMS electronic control module has failed. Repair: Replace the VIMS electronic control module. Refer to the Testing and Adjusting, "Module-Replace" section for additional information.STOP
NOT OK - The resistance is greater than 5000 ohms.Repair: The machine harness has failed. The SPI data link circuit is open in the machine harness. Repair the machine harness or replace the machine harness. STOP
Cat SIS web machinery list:
Parts cord Caterpillar catalog:
9R7958
CORD AS
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
2313052
CORD AS
414E, 416D, 416E, 416F, 420D, 420E, 420F, 424D, 428D, 430D, 430E, 430F, 432D, 442D, 450E, D3K XL, D4K XL, D5K LGP
414E, 416D, 416E, 416F, 420D, 420E, 420F, 424D, 428D, 430D, 430E, 430F, 432D, 442D, 450E, D3K XL, D4K XL, D5K LGP
2313052
CORD AS
414E, 416D, 416E, 416F, 420D, 420E, 420F, 424D, 428D, 430D, 430E, 430F, 432D, 442D, 450E, D3K XL, D4K XL, D5K LGP
414E, 416D, 416E, 416F, 420D, 420E, 420F, 424D, 428D, 430D, 430E, 430F, 432D, 442D, 450E, D3K XL, D4K XL, D5K LGP
2175912
CORD AS
216, 216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 902, 906, 908, D6R,...
216, 216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 902, 906, 908, D6R,...
1623874
CORD AS
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
1614150
CORD AS
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
1596108
CORD AS-HEATER
216, 228, 236, 247, 248, 267, 287, 924G, 924GZ, 930G, IT28G
216, 228, 236, 247, 248, 267, 287, 924G, 924GZ, 930G, IT28G
1549972
CORD
35, 45, 55
35, 45, 55
3523953
CORD AS
C-12, C12, C18, C32
C-12, C12, C18, C32
2137328
CORD AS
3126B, C7
3126B, C7
3685713
CORD AS-HEATER
416F, 420F, 430F, 450F
416F, 420F, 430F, 450F
4176997
CORD AS-HEATER
428F, 432F, 434F, 444F
428F, 432F, 434F, 444F
3453567
CORD AS-HEATER ELEMENT
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 303E CR, 906H2, 907H2, 908H2, 910K, 914K
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 303E CR, 906H2, 907H2, 908H2, 910K, 914K