1598104 COUNTERWEIGHT GP Caterpillar parts
D8R, D8R II
Rating:
Alternative (cross code) number:
CA1598104
159-8104
1598104
CA1598104
159-8104
1598104
TRACK-TYPE TRACTOR,
Information:
href="https://avspare.com/spare/caterpillar/125250/">125/250 volt single phase operation.Troubleshooting Charts
Initial Operating Procedure After Repairs
The engine should not be operated at rated RPM immediately after the cause for the fault condition has been repaired. The following procedure may prevent additional failures if the ACTUAL CAUSE of the fault condition was not detected.1. Remove build-up relay (K1) and disconnect wire 8 from regulator assembly (A1).2. Start the engine and operate it at low RPM. The residual magnetism in the field should produce approximately 2 to 10 volts (generator output). A shorted controlled rectifier (CR1) will allow the field to produce higher output voltage.3. Stop the engine and install build-up relay (K1).4. Start the engine and operate it at low idle RPM. The output voltage will vary (up and down) when the points in the build-up relay are properly operating. If the output voltage is 2 to 10 volts and steady, either the build-up relay points are open or the controlled rectifier is open. If the build-up relay points remain closed, generator voltage will be higher and steady.5. Stop the engine and reconnect wire to terminal 8.6. Start the engine and operate it at low RPM. The output voltage should be approximately 66% of generator rated voltage. If the output voltage is either too high or is not steady, the reference circuit may be open or the regulator assembly may be defective.7. With the engine operating at low idle RPM and the generator producing a steady voltage (approximately 66% of rated voltage), slowly increase the RPM to rated RPM. Adjust the voltage level control to generator rated voltage. The generator is now ready to use.Testing Power Rectifiers And Control Rectifiers
The power rectifiers and control rectifiers, used in the SRCR generator sets, are of the stud mounted type. Extra care must be taken in the installation, testing and replacement of these components.
1. Power Rectifier CR3. 2. Field Rectifier CR5. 3. Power Rectifier CR4. 4. Control Rectifier CR1.Failure of these units can result from: 1. Excess Current2. Excess Voltage3. Excess Heat4. Incorrect Installation TorqueRectifier failure normally is a short, rarely an open. However, their operating characteristics may change to the extent that performance in the excitation circuit is unsatisfactory. This type of rectifier fault can not be detected with ohmmeter checks.
CHECKING POWER RECTIFIEROhmmeter checks may be performed on these rectifiers, but only to determine open or shorted conditions. To perform these tests, the positive and negative leads
Initial Operating Procedure After Repairs
The engine should not be operated at rated RPM immediately after the cause for the fault condition has been repaired. The following procedure may prevent additional failures if the ACTUAL CAUSE of the fault condition was not detected.1. Remove build-up relay (K1) and disconnect wire 8 from regulator assembly (A1).2. Start the engine and operate it at low RPM. The residual magnetism in the field should produce approximately 2 to 10 volts (generator output). A shorted controlled rectifier (CR1) will allow the field to produce higher output voltage.3. Stop the engine and install build-up relay (K1).4. Start the engine and operate it at low idle RPM. The output voltage will vary (up and down) when the points in the build-up relay are properly operating. If the output voltage is 2 to 10 volts and steady, either the build-up relay points are open or the controlled rectifier is open. If the build-up relay points remain closed, generator voltage will be higher and steady.5. Stop the engine and reconnect wire to terminal 8.6. Start the engine and operate it at low RPM. The output voltage should be approximately 66% of generator rated voltage. If the output voltage is either too high or is not steady, the reference circuit may be open or the regulator assembly may be defective.7. With the engine operating at low idle RPM and the generator producing a steady voltage (approximately 66% of rated voltage), slowly increase the RPM to rated RPM. Adjust the voltage level control to generator rated voltage. The generator is now ready to use.Testing Power Rectifiers And Control Rectifiers
The power rectifiers and control rectifiers, used in the SRCR generator sets, are of the stud mounted type. Extra care must be taken in the installation, testing and replacement of these components.
1. Power Rectifier CR3. 2. Field Rectifier CR5. 3. Power Rectifier CR4. 4. Control Rectifier CR1.Failure of these units can result from: 1. Excess Current2. Excess Voltage3. Excess Heat4. Incorrect Installation TorqueRectifier failure normally is a short, rarely an open. However, their operating characteristics may change to the extent that performance in the excitation circuit is unsatisfactory. This type of rectifier fault can not be detected with ohmmeter checks.
CHECKING POWER RECTIFIEROhmmeter checks may be performed on these rectifiers, but only to determine open or shorted conditions. To perform these tests, the positive and negative leads
Caterpillar SIS machinery equipment:
Caterpillar SIS
D8R Track-Type Tractor 7XM00001-UP (MACHINE) POWERED BY 3406 Engine »
159-8104
COUNTERWEIGHT GP
D8R TRACK-TYPE TRACTOR 9EM00001-UP (MACHINE) POWERED BY 3406C Engine »
159-8104
COUNTERWEIGHT GP
D8R Series II Track-Type Tractor 6YZ00001-UP (MACHINE) POWERED BY 3406E Engine »
159-8104
COUNTERWEIGHT GP
D8R TRACK-TYPE TRACTOR Differential Steering AKA00001-UP (MACHINE) POWERED BY 3406E Engine »
159-8104
COUNTERWEIGHT GP
Parts counterweight Caterpillar catalog:
2173648
COUNTERWEIGHT GP
D8R, D8T
D8R, D8T
6Y0610
COUNTERWEIGHT
980F, D7H, D8R, D8R II
980F, D7H, D8R, D8R II
1302582
COUNTERWEIGHT GP-FRONT
D8R, D8R II
D8R, D8R II
2538988
COUNTERWEIGHT GP
D8R, D8T
D8R, D8T
6Y0609
COUNTERWEIGHT GP
D7H, D8N, D8R
D7H, D8N, D8R
1882526
COUNTERWEIGHT GP
D7R II, D8R, D8R II, D9R, D9T
D7R II, D8R, D8R II, D9R, D9T
9Z9407
COUNTERWEIGHT AS
D8R, D8R II, D8T
D8R, D8R II, D8T
2173654
COUNTERWEIGHT
D8R, D8T
D8R, D8T
3138195
COUNTERWEIGHT GP
345D, 345D L, 349D, 349D L
345D, 345D L, 349D, 349D L
2737818
COUNTERWEIGHT & MOUNTING GP
319D, 319D L, 319D LN
319D, 319D L, 319D LN
6I6675
COUNTERWEIGHT GP
330 L
330 L
1907137
COUNTERWEIGHT & MOUNTING GP
330C, 330C L
330C, 330C L
3301332
COUNTERWEIGHT GP
315D L
315D L
2173648
COUNTERWEIGHT GP
D8R, D8T
D8R, D8T
1093738
COUNTERWEIGHT GP
914G, IT14G2
914G, IT14G2
2941323
COUNTERWEIGHT AR
345D, 345D L, 349D, 349D L
345D, 345D L, 349D, 349D L
2567518
COUNTERWEIGHT GP
924G, 924H, 928H, 928HZ, 930G, IT28G
924G, 924H, 928H, 928HZ, 930G, IT28G
2529986
COUNTERWEIGHT GP
416E, 420E, 430E
416E, 420E, 430E
1065881
COUNTERWEIGHT GP
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
3077924
COUNTERWEIGHT GP
312D, 312D L
312D, 312D L