Information:
Illustration 3 g01250277
Terminal locations at the P2 ECM connector for the passive analog sensors (P2-13) Engine coolant temperature (P2-30) Analog sensor return (P2-56) Intake manifold air temperature (P2-62) Fuel temperature
Illustration 4 g01155187
Terminal locations at the connector for the passive analog sensors (Terminal 1) Sensor signal (Terminal 2) Analog sensor return
Table 2
Troubleshooting Test Step     Values     Results    
1. Check for "Active" or "Logged Diagnostic Codes"
A. Remove electrical power from the ECM.
B. Connect Caterpillar Electronic Technician (ET) to the service tool connector.
C. Restore electrical power to the ECM.
D. Monitor the diagnostic codes on Cat ET. Check and record any diagnostic codes.
Wait at least 30 seconds in order for the diagnostic codes to become active.
E. Determine if a diagnostic code has occurred several times.
A diagnostic code that is logged several times is an indication of an intermittent problem. Most intermittent problems are the result of a poor connection between a socket and a pin in a connector or of a poor connection between a wire and a terminal.
F. Determine if the problem is active and related to one of the following diagnostic codes:3,4
G. Remove electrical power from the ECM.    
A diagnostic code is not active.    
Result: A diagnostic code is not active.
The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".
Result: An active 3 diagnostic code is present.
Proceed to Test Step 2.
Result: An active 4 diagnostic code is present.
Proceed to Test Step 4.    
2. Check for Battery Voltage on the Signal Wire
A. Restore electrical power to the ECM.
B. Measure the voltage on the harness side of the sensor connector between pin 1 and engine ground for the suspect sensor.
C. Remove electrical power from the ECM.    
The signal voltage is less than battery voltage.     Result: The signal voltage is less than battery voltage.
Proceed to Test Step 3.
Result: The signal voltage is equal to battery voltage.
There is a short circuit to battery voltage in the harness. Repair the wiring harness or replace the wiring harness. Verify that the repair has resolved the original problem.
   
3. Create a Short Circuit at the Connector for the Suspect Sensor
A. Disconnect the suspect sensor.
B. Fabricate a jumper wire that is long enough to create a test circuit across the harness side of the sensor connector. Crimp connector pins to each end of the jumper wire.
C. Install the jumper wire between terminal 1 (sensor signal) and terminal 2 (sensor return) at the sensor connector.
D. Restore electrical power to the ECM.
E. Access the "Active Diagnostic Code" screen on Cat ET. Check for an active 4 diagnostic code for the suspect sensor.
Wait at least 30 seconds in order for the diagnostic codes to become active.
F. Remove electrical power from the ECM.
   
A 4 diagnostic code is now active for the suspect sensor.    
Result: A 3 diagnostic code was active before creating the short at the sensor connector. A 4 diagnostic code became active after creating the short at the sensor connector. The wiring between the
Caterpillar parts catalog:
Parts coupler Caterpillar catalog:
4447499
COUPLER GP-QUICK
307E, 308E
307E, 308E
4447498
COUPLER AR-QUICK
307E, 308E
307E, 308E
1645567
COUPLER AS-QUICK DISCONNECT
1090, 1190, 1190T, 1290T, 216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262...
1090, 1190, 1190T, 1290T, 216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262...
6V0398
COUPLER-DISC
312D2, 312D2 GC, 312D2 L, 313D2, D3B, D8L
312D2, 312D2 GC, 312D2 L, 313D2, D3B, D8L
3608914
COUPLER-QUICK DISCONNECT
M313D, M315D
M313D, M315D
3608907
COUPLER-QUICK DISCONNECT
M313D, M315D
M313D, M315D
4447492
COUPLER AS
305.5E, 305E
305.5E, 305E
4447493
COUPLER AS
303.5E, 303E CR, 304E
303.5E, 303E CR, 304E
3611175
COUPLER
302.2D, 302.4D, 302.7D
302.2D, 302.4D, 302.7D
8P8090
COUPLER
578, 583R, 589
578, 583R, 589
1P7919
COUPLER-MALE
12G, 14G, 14H, 14H NA, 16G, 16H, 16H NA, 24H, 375, 375 L, 385B, 385C, 385C FS, 385C L, 390D, 390D L, 5080, 5090B, 578, 583R, 589, 631C, 637, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 666, 69D, 769, 76...
12G, 14G, 14H, 14H NA, 16G, 16H, 16H NA, 24H, 375, 375 L, 385B, 385C, 385C FS, 385C L, 390D, 390D L, 5080, 5090B, 578, 583R, 589, 631C, 637, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 666, 69D, 769, 76...
8T5373
COUPLER-MALE
5110B, 5130, 5130B, 5230, 5230B, 621E, 621F, 623E, 627E, 627F, 627G, 631E, 637E, 637G, 651E, 657E, 824G, 824G II, 825G, 826G, 844, 844H, 953D, 963D, 966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972...
5110B, 5130, 5130B, 5230, 5230B, 621E, 621F, 623E, 627E, 627F, 627G, 631E, 637E, 637G, 651E, 657E, 824G, 824G II, 825G, 826G, 844, 844H, 953D, 963D, 966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972...
5W2613
COUPLER
205, 206, 212
205, 206, 212
3972572
COUPLER-QUICK
301.7D CR, 302.7D
301.7D CR, 302.7D
3972571
COUPLER-QUICK
301.7D CR, 302.7D
301.7D CR, 302.7D