Connections of the transmission solenoid 4This diagnostic code is associated with the transmission 4 solenoid valve. The FMI 06 means that the ECU has determined that there is a short to ground in the solenoid circuit.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECU has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1404 FMI 06 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness.Expected Result:The FMI 06 changes to FMI 05 when the solenoid is disconnected.Results:
YES - The FMI 06 changes to FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECU.
At the machine harness connector, measure the resistance from the signal contact J1-52 (wire 755-OR) to all contacts that are used in the machine harness connectors for the ECU.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-52 (wire 755-OR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all of the harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1404 FMI 06.Expected Result:The CID 1404 FMI 06 is active.Results:
YES - The CID 1404 FMI 06 is active. The diagnostic code has not been corrected.Repair: It is unlikely that the ECU has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic
Parts coupling Caterpillar catalog:
3E6832
COUPLING AS-
Caterpillar
Caterpillar
3E6831
COUPLING AS
Caterpillar
Caterpillar
3E6806
COUPLING AS-
Caterpillar
Caterpillar
3E6805
COUPLING AS-
Caterpillar
Caterpillar
3E6803
COUPLING AS-
Caterpillar
Caterpillar
3E6802
COUPLING AS-
Caterpillar
Caterpillar
3F3917
COUPLING
Caterpillar
Caterpillar
3F3650
COUPLING G.
Caterpillar
Caterpillar
3F1238
COUPLING
Caterpillar
Caterpillar
3F0576
COUPLING G.
Caterpillar
Caterpillar
3F0575
COUPLING
Caterpillar
Caterpillar
3E6836
COUPLING AS
Caterpillar
Caterpillar