4962307 COUPLING AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4962307
496-2307
4962307
CA4962307
496-2307
4962307
Weight: 1 pounds 0 kg.
Information:
Illustration 1 g01197962
Schematic for the Lower Anti-Drift SolenoidThis diagnostic code is recorded when the ECM detects a short to ground in the electrical path from the ECM to the solenoid. The possible causes for this diagnostic code are listed:
The internal windings for the solenoid have low impedance.
The internal windings for the solenoid are shorted.
The signal circuit from the ECM to the solenoid is shorted to ground.System Response:The lift linkage will not lower.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected. Note: Ensure that the diagnostic code indicator is active and that the diagnostic code is active.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position.
Observe the ON/OFF status of the diagnostic code indicator.
Disconnect the solenoid with the diagnostic code from the harness.Expected Result:The diagnostic code indicator remains active.Results:
YES - The diagnostic code indicator remains active and the diagnostic code remains active. The harness has failed or the ECM has failed. Proceed to test step 2.
NO - The diagnostic code indicator is inactive.Repair: The solenoid has failed or the connecting harness has failed. Repeat this test in order to verify the failure. Repair the solenoid or replace the solenoid. Repair the connecting harness or replace the connecting harness at the solenoid. Stop.Test Step 2. CHECK FOR A SHORTED HARNESS.
Turn the disconnect switch to the OFF position.
The solenoid valve from the previous test step remains disconnected.
Disconnect the harness from the implement ECM.
At the harness connector for the ECM, measure the resistance between contact for the failed solenoid circuit J1-61 (wire P945-OR) and contact J1-60 (ground wire J814-BK).Expected Result:The resistance is less than 5000 Ohms.Results:
YES - The resistance is less than 5000 Ohms.Repair: The harness has failed. The corresponding solenoid wire is shorted to ground in the harness. Repair the harness or replace the harness. Stop.
NO - Resistance is greater than 5000 Ohms (no continuity).Repair: The harness circuit resistance is correct. It is unlikely that the ECM has failed. Exit this procedure and perform this troubleshooting procedure again. Also recheck if the diagnostic code indicator is active for this diagnostic code. If the cause is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
Parts coupling Caterpillar catalog:
4959308
COUPLING
Caterpillar
Caterpillar
4959284
COUPLING
Caterpillar
Caterpillar
4950524
COUPLING AS-
Caterpillar
Caterpillar
4947729
COUPLING
Caterpillar
Caterpillar
4946493
COUPLING AS
Caterpillar
Caterpillar
4944156
COUPLING
Caterpillar
Caterpillar
4962315
COUPLING AS
Caterpillar
Caterpillar
4962314
COUPLING AS
Caterpillar
Caterpillar
4962313
COUPLING AS
Caterpillar
Caterpillar
4962312
COUPLING AS
Caterpillar
Caterpillar
4962311
COUPLING AS
Caterpillar
Caterpillar
4962310
COUPLING AS
Caterpillar
Caterpillar