1959244 COVER-VALVE Caterpillar parts
216, 228, 236, 247, 248, 267, 287, 3034, 906
Rating:
Alternative (cross code) number:
CA1959244
195-9244
1959244
CA1959244
195-9244
1959244
Weight: 2 pounds 1 kg.
COMPACT WHEEL LOADER, SKID STEER LOADER,
Compare Prices:
As an associate, we earn commssions on qualifying purchases through the links below
$150.95
02 Dec 2020
13.0[5.85] Pounds
-: -
All States Ag Parts Parts A.S.A.P. Used Valve Cover Caterpillar 226 906 248 252 267 247 216 287 277 242 236 3034 257 246 232 262 228 195-9244
Fits Caterpillar Skid Steer Loader(s) 216, 226, 228, 232, 236, 242, 246, 247, 248, 252, 257, 262, 267, 277, 287 || Fits Caterpillar Construction & Industrial(s) 906 || Fits Caterpillar Engine(s) 3034 || Replaces Caterpillar OEM nos 195-9244 || Due to the nature of used parts, this part may not be in stock at all times. We will notify you within one business day if we are unable to ship the part for any reason.
Fits Caterpillar Skid Steer Loader(s) 216, 226, 228, 232, 236, 242, 246, 247, 248, 252, 257, 262, 267, 277, 287 || Fits Caterpillar Construction & Industrial(s) 906 || Fits Caterpillar Engine(s) 3034 || Replaces Caterpillar OEM nos 195-9244 || Due to the nature of used parts, this part may not be in stock at all times. We will notify you within one business day if we are unable to ship the part for any reason.
Compatible equipment models: 1959244:
Caterpillar parts catalog:
Information:
All Caterpillar Generators SetsReference: Form SEBD0660, "Operating Environment-And Its Effects On SR4 Generators"; Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators."There is a potential risk of stator failure for generators stored or operated in contaminated and/or humid environments. Problems can develop in the generator windings when dust, water, salt or grease is present, or anytime the generator windings are below the dewpoint.
Contaminants such as dirt, dust, grease, oil films, salt and water should not be allowed to accumulate on the stator windings. These conditions increase the risk of moisture collecting in the windings. Moisture can provide a conductive pathway between bundles of wire. When this occurs, current will leak from the higher voltage bundle to the lower voltage bundle. The current leak produces heat and causes a breakdown and charring of the winding insulation. If the problem goes undetected, the windings may be severely damaged.
The following preventive maintenance activities will reduce the risk of stator failure for generators stored or operated in contaminated and/or humid environments.
Safety
When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. * Remove all fuses.
* Make sure the generator engine is stopped.* Make sure all batteries are disconnected.* Make sure all capacitors are discharged.* Failure to do so could result in personal injury or death.* Make sure residual voltage in the rotor, stator and the generator is discharged.
Attach a "DO NOT OPERATE" or similar warning tag to start switch or controls before performing any service or repairs.
"DO NOT OPERATE" tags are available from Caterpillar. Order Form SEHS7332.
When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.
* Improper test equipment may fail and present a high voltage shock hazard to its user.* Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.
New Equipment
Storage
After a new generator arrives on site it should be protected against moisture until it is installed.
When a generator is in storage, moisture condenses in the windings. To minimize condensation, always put the generator in a dry storage area.
When the generator is placed in storage, it is necessary that a megger insulation resistance check be performed and the results recorded. The temperature and level of humidity should also be recorded. This check will provide a baseline for future reference.
It is important that this baseline be established when the unit is dry.To guard against collective contaminants, the generator should be covered with a plastic cover or similar type of protective cloth. The protective cover should extend to the ground, but remain loose around the generator in order to allow it to properly breathe.
Caterpillar recommends maintaining the insulated parts and the air surrounding them at a temperature of at least 5° C (9°F) higher than the room temperature in which the equipment is located. This will prevent condensation. Normal methods of providing the heat required
Contaminants such as dirt, dust, grease, oil films, salt and water should not be allowed to accumulate on the stator windings. These conditions increase the risk of moisture collecting in the windings. Moisture can provide a conductive pathway between bundles of wire. When this occurs, current will leak from the higher voltage bundle to the lower voltage bundle. The current leak produces heat and causes a breakdown and charring of the winding insulation. If the problem goes undetected, the windings may be severely damaged.
The following preventive maintenance activities will reduce the risk of stator failure for generators stored or operated in contaminated and/or humid environments.
Safety
When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. * Remove all fuses.
* Make sure the generator engine is stopped.* Make sure all batteries are disconnected.* Make sure all capacitors are discharged.* Failure to do so could result in personal injury or death.* Make sure residual voltage in the rotor, stator and the generator is discharged.
Attach a "DO NOT OPERATE" or similar warning tag to start switch or controls before performing any service or repairs.
"DO NOT OPERATE" tags are available from Caterpillar. Order Form SEHS7332.
When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.
* Improper test equipment may fail and present a high voltage shock hazard to its user.* Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.
New Equipment
Storage
After a new generator arrives on site it should be protected against moisture until it is installed.
When a generator is in storage, moisture condenses in the windings. To minimize condensation, always put the generator in a dry storage area.
When the generator is placed in storage, it is necessary that a megger insulation resistance check be performed and the results recorded. The temperature and level of humidity should also be recorded. This check will provide a baseline for future reference.
It is important that this baseline be established when the unit is dry.To guard against collective contaminants, the generator should be covered with a plastic cover or similar type of protective cloth. The protective cover should extend to the ground, but remain loose around the generator in order to allow it to properly breathe.
Caterpillar recommends maintaining the insulated parts and the air surrounding them at a temperature of at least 5° C (9°F) higher than the room temperature in which the equipment is located. This will prevent condensation. Normal methods of providing the heat required
Parts cover Caterpillar catalog:
1429118
COVER GP-INSTRUMENT PANEL
216, 216B, 226B, 228, 232B, 236, 236B, 242B, 247, 247B, 248, 252B, 257B, 267, 267B, 268B, 287
216, 216B, 226B, 228, 232B, 236, 236B, 242B, 247, 247B, 248, 252B, 257B, 267, 267B, 268B, 287
3E5153
COVER-STARTING MOTOR
216, 228, 236, 236B, 236B3, 242B3, 246C, 247, 248, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 3054...
216, 228, 236, 236B, 236B3, 242B3, 246C, 247, 248, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 3054...
9R7980
COVER
120H ES, 12H ES, 140H ES, 143H, 14H NA, 160H ES, 163H NA, 16H NA, 216, 216B, 216B3, 226B, 226B3, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B...
120H ES, 12H ES, 140H ES, 143H, 14H NA, 160H ES, 163H NA, 16H NA, 216, 216B, 216B3, 226B, 226B3, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247B, 247B3, 252B, 252B3, 256C, 257B, 257B...
1530108
COVER
216, 228, 236, 247, 267, 3034, 906
216, 228, 236, 247, 267, 3034, 906
1536848
COVER
216, 216B, 226B, 232B, 242B, 247B, 257B, 3003, 301.5, 3011C, 3013, 3013C, 3014, 302.5, 3024, 3024C, 303.5, 304.5, 902, C0.5, C0.7, C1.1, C1.5, C1.6, C2.2, CB-14, CB-214D, CB-214E, CB-334E
216, 216B, 226B, 232B, 242B, 247B, 257B, 3003, 301.5, 3011C, 3013, 3013C, 3014, 302.5, 3024, 3024C, 303.5, 304.5, 902, C0.5, C0.7, C1.1, C1.5, C1.6, C2.2, CB-14, CB-214D, CB-214E, CB-334E
2366650
COVER
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
1862360
COVER AS
216, 216B, 216B3, 226B, 226B3, 232B, 236, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 248, 252B, 256C, 257B, 257B3, 259B3, 262C, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C
216, 216B, 216B3, 226B, 226B3, 232B, 236, 236B, 236B3, 242B, 242B3, 246C, 247B, 247B3, 248, 252B, 256C, 257B, 257B3, 259B3, 262C, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C
2194362
COVER
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
1991182
COVER
3034, 3054B, 3056
3034, 3054B, 3056
2075978
COVER
3034
3034
1555519
COVER GP-FUSE PANEL
902, 906, 908
902, 906, 908
1628549
COVER AS
902, 906, 908
902, 906, 908
1530108
COVER
216, 228, 236, 247, 267, 3034, 906
216, 228, 236, 247, 267, 3034, 906
1590055
COVER
216, 228, 236, 248, 3034, 906
216, 228, 236, 248, 3034, 906
1526865
COVER
216, 228, 906
216, 228, 906
1752405
COVER AS
35, 45, 55
35, 45, 55
1539940
COVER
35, 45, 55
35, 45, 55
1576127
COVER
35, 45, 55
35, 45, 55
2366650
COVER
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
1469303
COVER
216, 228, 236, 247, 248, 267
216, 228, 236, 247, 248, 267
2177352
COVER-VALVE
216, 216B, 216B3, 226B, 226B3, 232B, 242B, 247B, 247B3, 257B, 3024C, CB22B, CB24B, CB32B, CC24B
216, 216B, 216B3, 226B, 226B3, 232B, 242B, 247B, 247B3, 257B, 3024C, CB22B, CB24B, CB32B, CC24B
1536848
COVER
216, 216B, 226B, 232B, 242B, 247B, 257B, 3003, 301.5, 3011C, 3013, 3013C, 3014, 302.5, 3024, 3024C, 303.5, 304.5, 902, C0.5, C0.7, C1.1, C1.5, C1.6, C2.2, CB-14, CB-214D, CB-214E, CB-334E
216, 216B, 226B, 232B, 242B, 247B, 257B, 3003, 301.5, 3011C, 3013, 3013C, 3014, 302.5, 3024, 3024C, 303.5, 304.5, 902, C0.5, C0.7, C1.1, C1.5, C1.6, C2.2, CB-14, CB-214D, CB-214E, CB-334E
0357293
COVER
216, 228, 236, 248, 3034, 3054, 3054B, 3056, PS-300B, TH210
216, 228, 236, 248, 3034, 3054, 3054B, 3056, PS-300B, TH210
3603984
COVER-VALVE
216, 216B, 216B3, 232B, 242B, 3024C, AP-255E, BB-621C, C2.2, C4.4, CB-334E, CB-34, CB34B, CB34B XW, CC34B
216, 216B, 216B3, 232B, 242B, 3024C, AP-255E, BB-621C, C2.2, C4.4, CB-334E, CB-34, CB34B, CB34B XW, CC34B