1C4249 COVER Caterpillar parts
Rating:
Alternative (cross code) number:
CA1C4249
1C-4249
1C4249
CA1C4249
1C-4249
1C4249
Weight: 0.78 pounds 0 kg.
Information:
Problem 1: Pump motor does not run. Cause:Voltage supply interrupted.Solution:a. Check voltage supply or fuses.b. Check line leading from the fuses to the pump plug and to the timer. Cause:Circuit board defectiveSolution:a. Replace printed circuit board. Cause:Electric motor defective.Solution:a. Check voltage supply to motor, replace if needed. Problem 2: Pump does not deliver lubricant. Cause:Reservoir empty.Solution:a. Refill reservoir with clean lubricant. Cause:Air pockets in lubricantSolution:a. Bleed air at outlet fitting on pump element. Cause:Pump suction hole clogged.Solution:a. Remove pump element, check suction hole for foreign particles. Cause:Pump piston worn.Solution:a. Replace pump element. Cause:Check valve in pump element defective or clogged.Solution:a. Replace pump element. Problem 3: Blockage of downstream progressive system. Cause:Bearings, lines or metering devices clogged (lubricant leaking from relief valve).Solution:Clean or replace if needed. If disassembling metering device for cleaning purposes, do not interchange pistons when reassembling.
Metering device (typical outlet numbering pattern)Testing:a. Allowing pump to run, loosen all main line connections from main metering device leading to secondary metering devices. If lubricant exits from outlet 1 of the main metering device than the blockage will found in the lubrication circuit of the secondary metering devices. In the case of a blocked metering deviceSolution:Clean or replace metering device.Testing procedure for blockage:b. With pump running, disconnect all feed lines from secondary metering devices one after another. If lubricant exits under pressure from outlet 3 of the metering device, then the blockage will be found in the distribution line of outlet 3.c. Replace relief valve. When checking individual outlets, keep outlet loosened for quite a while because for each motor revolution there is only one piston stroke. A complete cycle of all the metering devices requires several strokes.
Metering device (typical outlet numbering pattern)Testing:a. Allowing pump to run, loosen all main line connections from main metering device leading to secondary metering devices. If lubricant exits from outlet 1 of the main metering device than the blockage will found in the lubrication circuit of the secondary metering devices. In the case of a blocked metering deviceSolution:Clean or replace metering device.Testing procedure for blockage:b. With pump running, disconnect all feed lines from secondary metering devices one after another. If lubricant exits under pressure from outlet 3 of the metering device, then the blockage will be found in the distribution line of outlet 3.c. Replace relief valve. When checking individual outlets, keep outlet loosened for quite a while because for each motor revolution there is only one piston stroke. A complete cycle of all the metering devices requires several strokes.
Parts cover Caterpillar catalog:
1C3739
COVER
Caterpillar
Caterpillar
1C1444
COVER A.1C81
Caterpillar
Caterpillar
1C1436
COVER A.
Caterpillar
Caterpillar
1C0086
COVER
Caterpillar
Caterpillar
1C0081
COVER
Caterpillar
Caterpillar
1B9751
COVER
Caterpillar
Caterpillar
1D3058
COVER
Caterpillar
Caterpillar
1D2945
COVER
Caterpillar
Caterpillar
1D0851
COVER
Caterpillar
Caterpillar
1C7824
COVER
Caterpillar
Caterpillar
1C7191
COVER
Caterpillar
Caterpillar
1C4431
COVER
Caterpillar
Caterpillar