ACDelco PF 492, ALCO FILTER MD-253, MD-289, ALLIS-CHALMERS 0666421-3, 3042912, 3042912-0, 662421-4, 666421-3, 70666421, 73042912, AMC Filter CO-1709, ASAS AS 171 H, BALDWIN PT557-10, PT9010, CASE IH L-052764, L-52764, CATERPILLAR 1R-0720, 1R-0741, 2H-1560, 2J-1360, 2J-1550, 2J-1560, 2J-1660, 2J-6135, 2K-8257, 3J-0670, 3K-6727, 4D-2954, 4F-6064, 4J-0806, 4J-6064, 4J-6068, 4J-6164, 4J-806, 4K-1537, 5H-6174, 5J-6174, 6F-9163, 6J-3963, 6J-8958, S30-262A, S3O-262A, CLEAN FILTERS ML 413, COOPERS AZH 004, AZL 081, G 695, COOPERSFIAAM FILTERS FA4616, CROSLAND 492, DONALDSON HFP556064, P164205, P556064, DONIT FILTER 49.15.778, ELOFIC EXL-601, FIAT 6686884, 70666421, 73042912, FIATALLIS 666421-3, 70666421, 73042912, 75213131, FIL FILTER ML 224, FLEETGUARD HF6098, LF603, FRAD 45.65.07/40, FRAM C1660, C1660A, GENERAL MOTORS 6436205, GUD FILTERS G 695, HENGST FILTER E51H, ISUZU 1-30601-879-0, 1-30601-888-0, KNECHT AF 56, KOMATSU 130-601-8790, 130-601-8880, 131-60-48210, 784 620, LUBERFINER LH 4920, LP 560, LP 74, MAHLE FILTER HX 1, HX 79, MISFAT L463, P.B.R. AC-3006, PUROLATOR EP 205, H 50205, L 50205, SCT Germany SH 4720, TECNOCAR OP270, TEHO 5185, D 185, UFI 25.453.00, 25.463.00, VOLVO 5205493, WOODGATE WGH 6098,

Compatible equipment models: 2J6135:

HYDRAULIC CONTROL  184   Caterpillar
Number on catalog scheme: None
  For full view, you need register

Information:


Illustration 1 g01436045
Connections of the solenoid "A" on valve 1
Illustration 2 g01436047
Connections of the solenoid "A" on valve 1This diagnostic code is associated with solenoid "A" on valve 1. The FMI 04 means that the valve ECM has determined that either an open in the circuit or a short to ground in the return circuit exists.The possible causes are listed:
The return circuit of the solenoid is shorted to ground.
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The valve ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2212 FMI 04 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Note: Check the configuration of your machine for the number of implement electronic control modules. The following table lists some of the configurations that are available:
Table 1
Machines with one Electronic Implement Control    
Electronic Implement Control 2     Fourth Valve, Ripper, or Winch    
Table 2
Machines with two Electronic Implement Controls    
Electronic Implement Control 2     Fourth Valve or Ripper    
Electronic Implement Control 3     Winch    Test Step 1. CHECK THE RETURN CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the solenoid from the machine harness.
Disconnect the machine harness at the valve ECM.
At the harness connector for the valve ECM, measure the resistance from the supply wire to all contacts that are used in the machine harness connector.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
YES - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NO - Each resistance measurement is NOT greater than 5000 ohms. There is a short in the machine harness between the supply wire and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
The key start switch and the disconnect switch remain in the OFF position.
The machine harness remains disconnected from the valve ECM.
The solenoid remains disconnected from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 to contact 2.
At the machine harness connector for the valve ECM, measure the resistance from the supply wire to the return wire.Expected Result:The resistance should be less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in the supply wire or the return wire of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE SOLENOID.
Remove the jumper wire from the

Caterpillar parts catalog:

Caterpillar parts catalog
184 & 193 HYD. CONTROLS 37E00001-00409
D9 TRACTOR QUAD-TRACK 66A01419-03265 (MACHINE)
184 & 193 HYD. CONTROLS 37E00001-00409


Parts cover Caterpillar catalog:

8M5367 COVER
561B, 977H
6B7590 COVER
561B, 824, 834, 977H, 988
9M6366 COVER
12E, 16, 561B, 621, 651, 657, 769, 824, 824B, 834, 955H, 977H, 980, 988, D8H, D9G
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.