Information:
Illustration 1 g01007938
Schematic
Illustration 2 g01007927
P1 ECM connectorTest Step 1. Check for Connector Damage
Turn the keyswitch to the OFF/RESET position.
Check the connectors and wiring for the following problems: damage, corrosion, abrasion and incorrect attachment.Expected Result:The connectors and the wiring are free of the following problems: damage, corrosion, abrasion and incorrect attachment.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the connectors or wiring and/or replace the connectors or wiring.STOPTest Step 2. Check the Switch on Cat ET
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position.
Operate the ground level shutdown switch. Observe the status for the ground level shutdown switch on Cat ET.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switchis "ON" with the switch in the SHUTDOWN position. The status is "OFF" when the switch is in the RUN position.Results:
OK - The switch is operating normally.STOP
Not OK - Proceed to Test Step 3.Test Step 3. Short the Wires at the SwitchRecord the switch wiring before removing the wires.
Disconnect the wires from the ground level shutdown switch.
Install a jumper wire between P700:3 (Ground Level Shutdown Switch (N/O)) and P700:2 (Digital Return). Leave P700:1 (Ground Level Shutdown Switch (N/O)) open.
Turn the keyswitch to the ON position.
Observe the status of the ground level shutdown switch on Cat ET. The status of the switch should be "OFF".
Disconnect the wires from P700:3 (Ground Level Shutdown Switch (N/C)) and P700:2 (Digital Return).
Install a jumper wire between P700:1 (Ground Level Shutdown Switch (N/O)) and P700:2 (Digital Return).
Turn the keyswitch to the OFF/RESET position.
Turn the keyswitch to the ON position.
Observe the status of the ground level shutdown switch on Cat ET. The status of the switch should be "ON".
Remove the wire short.Expected Result:The status of the ground level shutdown switch changes accordingly as you short the terminals of the P700 ground level shutdown switch connector.Results:
OK - The problem is not with the harness and/or in the ECM.Repair: Temporarily connect a new switch. Verify that the new switch solves the problem before you permanently install the new switch.STOP
Not OK - There is a problem in the harness and/or the ECM. Proceed to Test Step 4.Test Step 4. Check for a Short Circuit in the Wiring Harness
Turn the keyswitch to the OFF/RESET position.
Disconnect the J1/P1 ECM connector and the J700/P700 ground level shutdown switch connector.
Measure the resistance between P1:40 (Ground Level Shutdown Switch (N/O)) and P1:5 (Digital Return).
Measure the resistance between P1:23 (Ground Level Shutdown Switch (N/C)) and P1:5 (Digital Return).
Measure the resistance between P1:40 (Ground Level Shutdown Switch (N/O)) and P1:23 (Ground Level Shutdown Switch (N/C)).
Measure the resistance between P1:23 (Ground Level Shutdown Switch (N/C)) and engine ground.
Measure the resistance between P1:40 (Ground Level Shutdown Switch (N/O)) and engine ground. Expected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - Proceed to Test Step 5.
Not OK - There is a short in the harness between the switch and the ECM.Repair: Repair the connectors or wiring and/or replace the connectors or wiring.STOPTest Step 5. Check the Resistance Through the
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cover Caterpillar catalog:
4368108
COVER GP-ENGINE
C140-16
C140-16
2P6256
COVER GP
14G, 1673C, 3306, 627B, D6C
14G, 1673C, 3306, 627B, D6C
2132975
COVER GP-ACCESS
613C II
613C II
3242802
COVER GP-PUMP
D10N, D10R
D10N, D10R
3818126
COVER GP-COOLING SYSTEM
3406B, 3406C
3406B, 3406C
2626960
COVER GP-ACCESS
C1.5, C2.2
C1.5, C2.2
3370067
COVER GP-REAR HOUSING
Caterpillar
Caterpillar
4180971
COVER GP-OIL PUMP
306E, 307E
306E, 307E
3424861
COVER GP-SHIPPING
834H, 988H
834H, 988H