3727318 COVER AS-ACCESS Caterpillar parts
D6R III, D6T, D7R II
Rating:
Alternative (cross code) number:
CA3727318
372-7318
3727318
CA3727318
372-7318
3727318
Weight: 6 pounds 3 kg.
TRACK-TYPE TRACTOR,
Information:
Engine Controls
Remote Control Panel (Status)
This section contains some general information about operation with the Remote Control Panel (Status). For more detailed information, refer to Systems Operation/Testing and Adjusting, SENR6420, "Control Panel (Status-Timing)".
Illustration 1 g00812724
Controls on the remote control panel (status)
(1) "DIAGNOSTIC RESET" switch
(2) Engine control switch
(3) "EMERGENCY STOP" button "DIAGNOSTIC RESET" switch (1) is a toggle switch that is used to clear diagnostic codes from the EIS control module. The switch cannot clear individual codes. Use of the switch will clear all codes that are active in the engine control module. Do not clear the codes until the problems that caused the codes are addressed.Engine control switch (2) is used to control starting the engine and stopping the engine.
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
"EMERGENCY STOP" button (3) is used to stop the engine in an emergency situation. When the button is pressed, the status control module shuts off the fuel via the gas shutoff valve. The module also terminates the ignition. The "EMERGENCY STOP" button must be reset before the engine will start.
Do not start the engine until the problem necessitating the emergency stop has been located and corrected.
Engine Control Switch
The engine control switch is a rotary switch that has four positions:
Stop
Automatic
Manual start
Cooldown/StopNote: Only the fault indicators on the status control module are reset when the engine control switch is turned to the Stop position. Diagnostic codes must be cleared with the "DIAGNOSTIC RESET" switch.Stop - When the engine control switch is turned to this position (12 o'clock), the fault indicators on the status control module are reset and the engine shuts down immediately. The power to the engine control module and the status control module is shut off. This method is not recommended for normal stopping.Automatic - When the engine control switch is in this position (3 o'clock), the system is configured for remote operation. When the remote start/stop initiate contact closes, the engine will start. When the remote start/stop initiate contact opens, the engine will shut down. If the cooling cycle is programmed, the engine will operate for the cooldown period before the engine stops.Manual start - When the engine control switch is turned to this position (6 o'clock), the engine will start. The engine will continue to operate when the switch is in this position.Cooldown/Stop - This is the preferred method for normal stopping. When the engine control switch is turned to this position (9 o'clock), the engine will continue to operate until a programmable cooling cycle has elapsed. The cooling cycle can be programmed for a 0 to 30 minute period. The default setting is five minutes.
Remote Control Panel (Status)
This section contains some general information about operation with the Remote Control Panel (Status). For more detailed information, refer to Systems Operation/Testing and Adjusting, SENR6420, "Control Panel (Status-Timing)".
Illustration 1 g00812724
Controls on the remote control panel (status)
(1) "DIAGNOSTIC RESET" switch
(2) Engine control switch
(3) "EMERGENCY STOP" button "DIAGNOSTIC RESET" switch (1) is a toggle switch that is used to clear diagnostic codes from the EIS control module. The switch cannot clear individual codes. Use of the switch will clear all codes that are active in the engine control module. Do not clear the codes until the problems that caused the codes are addressed.Engine control switch (2) is used to control starting the engine and stopping the engine.
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
"EMERGENCY STOP" button (3) is used to stop the engine in an emergency situation. When the button is pressed, the status control module shuts off the fuel via the gas shutoff valve. The module also terminates the ignition. The "EMERGENCY STOP" button must be reset before the engine will start.
Do not start the engine until the problem necessitating the emergency stop has been located and corrected.
Engine Control Switch
The engine control switch is a rotary switch that has four positions:
Stop
Automatic
Manual start
Cooldown/StopNote: Only the fault indicators on the status control module are reset when the engine control switch is turned to the Stop position. Diagnostic codes must be cleared with the "DIAGNOSTIC RESET" switch.Stop - When the engine control switch is turned to this position (12 o'clock), the fault indicators on the status control module are reset and the engine shuts down immediately. The power to the engine control module and the status control module is shut off. This method is not recommended for normal stopping.Automatic - When the engine control switch is in this position (3 o'clock), the system is configured for remote operation. When the remote start/stop initiate contact closes, the engine will start. When the remote start/stop initiate contact opens, the engine will shut down. If the cooling cycle is programmed, the engine will operate for the cooldown period before the engine stops.Manual start - When the engine control switch is turned to this position (6 o'clock), the engine will start. The engine will continue to operate when the switch is in this position.Cooldown/Stop - This is the preferred method for normal stopping. When the engine control switch is turned to this position (9 o'clock), the engine will continue to operate until a programmable cooling cycle has elapsed. The cooling cycle can be programmed for a 0 to 30 minute period. The default setting is five minutes.
Caterpillar parts catalog:
Parts cover Caterpillar catalog:
9S2255
COVER
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
9G0004
COVER AS-TERMINAL
120G, 120H, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12K, 12M, 130G, 135H, 1390, 140G, 140H, 140K, 140K 2, 143H, 14H, 160G, 160H, 160K, 163H, 16H, 215, 215B, 2384C, 2484C, 24H, 24M, 2590, 30/30, 305.5, 3...
120G, 120H, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12K, 12M, 130G, 135H, 1390, 140G, 140H, 140K, 140K 2, 143H, 14H, 160G, 160H, 160K, 163H, 16H, 215, 215B, 2384C, 2484C, 24H, 24M, 2590, 30/30, 305.5, 3...
1766995
COVER-PUMP
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 572R II, 65E, 725, 730, 75E, 814F, 815F, 816F, 85E, 95E, 966G II, 972G II, C-10, C-12, C12...
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 572R II, 65E, 725, 730, 75E, 814F, 815F, 816F, 85E, 95E, 966G II, 972G II, C-10, C-12, C12...
1771044
COVER
2290, 2390, 2391, 2491, 2590, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 511, 521, 521B, 522, 522B, 532, 541, 541 ...
2290, 2390, 2391, 2491, 2590, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 511, 521, 521B, 522, 522B, 532, 541, 541 ...
5D1911
COVER-HYDRAULIC CAP
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 16, 160G, 160H, 160H ES, 160H NA, 16...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 16, 160G, 160H, 160H ES, 160H NA, 16...
5M2043
COVER
225, 235, 245, 561C, 572G, 572R, 572R II, 951B, 953, 953C, 955C, 955H, 955K, 955L, 963B, 963C, 973, 973C, 973D, 977K, 983B, D5, D5B, D5E, D5H, D5H XL, D6C, D6D, D6E, D6E SR, D6G, D6G SR, D6G2 LGP, D6G...
225, 235, 245, 561C, 572G, 572R, 572R II, 951B, 953, 953C, 955C, 955H, 955K, 955L, 963B, 963C, 973, 973C, 973D, 977K, 983B, D5, D5B, D5E, D5H, D5H XL, D6C, D6D, D6E, D6E SR, D6G, D6G SR, D6G2 LGP, D6G...
3S3439
COVER-TOP
572G, 572R, 572R II, 578, 583R, 583T, 587R, 587T, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637E, 637G, 735, 740, 776, 776C, 776D, 777, 777B, 777D, 777F, 777G, 784B, 784C, 785, 785B, 785C, 785D, 789B, 7...
572G, 572R, 572R II, 578, 583R, 583T, 587R, 587T, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637E, 637G, 735, 740, 776, 776C, 776D, 777, 777B, 777D, 777F, 777G, 784B, 784C, 785, 785B, 785C, 785D, 789B, 7...
2100091
COVER
572R II, 583T, D6R III, D6T, D7R II, D8T
572R II, 583T, D6R III, D6T, D7R II, D8T
1119862
COVER-STARTING MOTOR
5130B, 836, 966F II, 980G, D10R, D11R, D7R II, D8R, D8R II, D9R
5130B, 836, 966F II, 980G, D10R, D11R, D7R II, D8R, D8R II, D9R
2321318
COVER AS
140G, D10N, D10R, D10T, D6R, D6R III, D6T, D7R II, D8R II, D8T
140G, D10N, D10R, D10T, D6R, D6R III, D6T, D7R II, D8R II, D8T
3048634
COVER AS-PRECLEANER
836H, 924H, 924HZ, 924K, 928HZ, 930K, 938K, 950K, 962K, 966K, 972K, 980K, D6T XL
836H, 924H, 924HZ, 924K, 928HZ, 930K, 938K, 950K, 962K, 966K, 972K, 980K, D6T XL
3253740
COVER AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3323502
COVER AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3516642
COVER AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3323517
COVER AS
D6T LGP, D6T XL
D6T LGP, D6T XL
2350399
COVER
D6R, D6R III, D6R STD, D6T, D7R II, D7R XR
D6R, D6R III, D6R STD, D6T, D7R II, D7R XR
2350895
COVER AS
D6R, D6R III, D6R STD, D6T
D6R, D6R III, D6R STD, D6T
2314390
COVER AS
D6R, D6R III, D6R STD, D6T
D6R, D6R III, D6R STD, D6T
2555210
COVER AS
D6R, D6R III, D6T
D6R, D6R III, D6T
2314389
COVER AS
D6R, D6R III
D6R, D6R III
2314385
COVER AS
D6R, D6R III, D6T
D6R, D6R III, D6T