Illustration 1 g03428675
Illustration of the electrical connections for the Glow Plug RelayThis diagnostic code is associated with the Glow Plug relay. The FMI 03 diagnostic code means that the Machine ECM has determined that the voltage of the relay circuit is above normal.The possible causes of the diagnostic code are listed:
The relay has failed.
The energize circuit of the relay is shorted to the +battery circuit.
The Machine ECM has failed. This situation is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the circuit are clean and secure. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2246 FMI 03 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE RELAY FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the relay and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-33 (wire F793-OR) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-33 (F793-OR) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened securely.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the diagnostic code is active.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active. The problem has not been corrected.Repair: Check the circuit again. A failure of the ECM is unlikely. Exit this procedure and perform this procedure again. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, refer to Troubleshooting, "Electronic Control Module (ECM)
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cover Caterpillar catalog:
4582985
COVER
Caterpillar
Caterpillar
4582984
COVER
Caterpillar
Caterpillar
4573458
COVER GP-ENGINE OIL LINE
Caterpillar
Caterpillar
4569382
COVER AS
Caterpillar
Caterpillar
4565468
COVER GP-VALVE MECHANISM
Caterpillar
Caterpillar
4564957
COVER GP-VALVE MECHANISM
Caterpillar
Caterpillar
4589805
COVER AS
Caterpillar
Caterpillar
4589804
COVER
Caterpillar
Caterpillar
4589796
COVER AS
Caterpillar
Caterpillar
4589795
COVER
Caterpillar
Caterpillar
4588581
COVER GP-VALVE MECHANISM
Caterpillar
Caterpillar
4586554
COVER GP-VALVE MECHANISM
Caterpillar
Caterpillar