Information:
All solenoid return wires are joined. The wires also connect to connector A-A4 (wire D989-BR-16) of the ARC.Note: The approximate coil resistance of the solenoid valves is 29.8 1.0 ohms at 25.0 °C (77.0 °F).This diagnostic code is recorded when the ARC reads the voltage of the solenoid circuit as above normal (short to +battery).Note: This procedure can cause new diagnostic codes to be recorded. Ignore these created diagnostic codes. Complete the following procedure. Then clear the created diagnostic codes.
CHECK THE SIGNAL CIRCUIT OF THE SOLENOID FOR A SHORT.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness from the solenoid.
Disconnect the machine harness connectors A and B from the ARC.
At the A and B machine harness connectors for the ARC, measure the resistance from the signal contact of the solenoid A-A4 (wire K989-BU-16) to +battery. The possible sources of positive voltage are connectors: A-A1, A-A3 and A-A5.Expected Result: Each resistance should be greater than 5000 ohms.Results:
OK: The resistance is greater than 5000 ohms. The machine harness is correct. Proceed to Step 2.
NO: There is a short in the machine harness. The short is between the signal contact of the solenoid and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness. STOP.
CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the key start switch to the ON position.
Clear all of the inactive diagnostic codes.
Operate the machine.
Stop the machine. Then place the parking brake switch in the OFF position.
Observe the status of the CID and the FMI. The diagnostic code is present or the diagnostic code is NOT present.Expected Result: The CID and the FMI for the solenoid is NO longer present.Results:
OK: The diagnostic code is NOT present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection and/or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. STOP.
NO: The diagnostic code has not been corrected. It is unlikely that the ARC is faulty. Exit this procedure and perform a check of the CID and the FMI again. Recheck the status of the diagnostic code. The diagnostic code is active or the diagnostic code is NOT active. If the cause of the diagnostic code is not found, replace the ARC. See Testing And Adjusting, "ARC - Replace". STOP.
CHECK THE SIGNAL CIRCUIT OF THE SOLENOID FOR A SHORT.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness from the solenoid.
Disconnect the machine harness connectors A and B from the ARC.
At the A and B machine harness connectors for the ARC, measure the resistance from the signal contact of the solenoid A-A4 (wire K989-BU-16) to +battery. The possible sources of positive voltage are connectors: A-A1, A-A3 and A-A5.Expected Result: Each resistance should be greater than 5000 ohms.Results:
OK: The resistance is greater than 5000 ohms. The machine harness is correct. Proceed to Step 2.
NO: There is a short in the machine harness. The short is between the signal contact of the solenoid and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness. STOP.
CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the key start switch to the ON position.
Clear all of the inactive diagnostic codes.
Operate the machine.
Stop the machine. Then place the parking brake switch in the OFF position.
Observe the status of the CID and the FMI. The diagnostic code is present or the diagnostic code is NOT present.Expected Result: The CID and the FMI for the solenoid is NO longer present.Results:
OK: The diagnostic code is NOT present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection and/or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. STOP.
NO: The diagnostic code has not been corrected. It is unlikely that the ARC is faulty. Exit this procedure and perform a check of the CID and the FMI again. Recheck the status of the diagnostic code. The diagnostic code is active or the diagnostic code is NOT active. If the cause of the diagnostic code is not found, replace the ARC. See Testing And Adjusting, "ARC - Replace". STOP.
Parts cover Caterpillar catalog:
6V4821
COVER
Caterpillar
Caterpillar
6V3110
COVER-BACK
Caterpillar
Caterpillar
6V2191
COVER
Caterpillar
Caterpillar
6V2132
COVER A
Caterpillar
Caterpillar
6V0391
COVER
Caterpillar
Caterpillar
6V0184
COVER TRANS
Caterpillar
Caterpillar
6Y1326
COVER-TC
Caterpillar
Caterpillar
6Y0189
COVER AS-PUMP
Caterpillar
Caterpillar
6W7268
COVER
Caterpillar
Caterpillar
6W3041
COVER A
Caterpillar
Caterpillar
6W2933
COVER
Caterpillar
Caterpillar
6V7781
COVER
Caterpillar
Caterpillar