8J2324 COVER Caterpillar parts
518, 528, 613, 613B, 615, 621, 621B, 627B, 814, 815, 950, 966C, 980B
Rating:
Alternative (cross code) number:
CA8J2324
8J-2324
8J2324
CA8J2324
8J-2324
8J2324
Weight: 0.60 pounds 0 kg.
SOIL COMPACTOR, WHEEL TRACTOR,
Compatible equipment models: 8J2324:
Information:
Introduction
Typical Subpan (Partial View)
(1) Time delay relay. (2) Slave relay. (3) Starting motor magnetic switch. (4) Circuit breaker. (5) VR4 voltage regulator. (6) Series boost (attachment).The VR4 is one of the voltage regulators available for SR4 generators. The VR4 is only used on standby SR4 generators which are: self-excited, 10/12 lead, and rated up to 400KW. Follow all safety procedures and warnings in the SR4 generator manuals.VR4 regulator (5) is located on side two of the subpan. The subpan is mounted above the generator.Operation
VR4 Regulator
(7) Terminal strip. (8) Rheostat (voltage level). (9) Fuse. (10) Rheostat (voltage gain).The purpose of the VR4 regulator is to keep generator output voltage at a rated value. There are two controls on the VR4 that are standard.* Voltage level rheostat (8) provides a no load voltage adjustment of approximately + 10 to - 25%.* Voltage gain rheostat (10) provides an adjustment to compensate for engine RPM droop with load. Rheostat (10) can be adjusted to keep the same voltage at no load and full load, even when there is a small change in frequency (rpm).The rheostats are multiple (30) turn. The adjusting screw on the rheostat does not have a fixed stop. To ensure the lowest position, turn the rheostat 32 full turns counterclockwise from the current position. To ensure the highest position, turn the rheostat 32 full turns clockwise from the current position.
SR4 Generator Schematic (Self-Excited 10/12 Lead)
(5) VR4 regulator. (11) Lines (3-phase output voltage). (12) Lines (sensing voltage and AC power). (13) Main stator. (14) Main rotor. (15) Exciter stator. (16) Exciter rotor. (17) Lines (VDC excitation voltage).VR4 regulator (5) senses generator output voltage between two phases. Lines (12) function as sensing lines by tapping into generator output. These lines are connected to terminals 20 and 24 on the VR4. Terminal 22 is also connected but is not used on the VR4. Like other SR4 generator regulators, the VR4 regulates voltage based on volts per hertz.Leads (12) also function to provide AC power for excitation to the VR4 regulator. The regulator rectifies the AC voltage and controls the excitation current to exciter stator (15).Fuse (9) limits the field current in the case of an internal short circuit or exciter field fault. VR4 regulators include an overcurrent shutoff to protect generator components. If the unit operates for an extended period of time at low rpm, the overcurrent shutoff may trip. It will reset automatically when the generator is completely shutoff. The approximate recommended minimum operating speed is: Four pole generator ... 1200 rpmSix pole generator ... 750 rpm
Typical Subpan (Partial View)
(1) Time delay relay. (2) Slave relay. (3) Starting motor magnetic switch. (4) Circuit breaker. (5) VR4 voltage regulator. (6) Series boost (attachment).The VR4 is one of the voltage regulators available for SR4 generators. The VR4 is only used on standby SR4 generators which are: self-excited, 10/12 lead, and rated up to 400KW. Follow all safety procedures and warnings in the SR4 generator manuals.VR4 regulator (5) is located on side two of the subpan. The subpan is mounted above the generator.Operation
VR4 Regulator
(7) Terminal strip. (8) Rheostat (voltage level). (9) Fuse. (10) Rheostat (voltage gain).The purpose of the VR4 regulator is to keep generator output voltage at a rated value. There are two controls on the VR4 that are standard.* Voltage level rheostat (8) provides a no load voltage adjustment of approximately + 10 to - 25%.* Voltage gain rheostat (10) provides an adjustment to compensate for engine RPM droop with load. Rheostat (10) can be adjusted to keep the same voltage at no load and full load, even when there is a small change in frequency (rpm).The rheostats are multiple (30) turn. The adjusting screw on the rheostat does not have a fixed stop. To ensure the lowest position, turn the rheostat 32 full turns counterclockwise from the current position. To ensure the highest position, turn the rheostat 32 full turns clockwise from the current position.
SR4 Generator Schematic (Self-Excited 10/12 Lead)
(5) VR4 regulator. (11) Lines (3-phase output voltage). (12) Lines (sensing voltage and AC power). (13) Main stator. (14) Main rotor. (15) Exciter stator. (16) Exciter rotor. (17) Lines (VDC excitation voltage).VR4 regulator (5) senses generator output voltage between two phases. Lines (12) function as sensing lines by tapping into generator output. These lines are connected to terminals 20 and 24 on the VR4. Terminal 22 is also connected but is not used on the VR4. Like other SR4 generator regulators, the VR4 regulates voltage based on volts per hertz.Leads (12) also function to provide AC power for excitation to the VR4 regulator. The regulator rectifies the AC voltage and controls the excitation current to exciter stator (15).Fuse (9) limits the field current in the case of an internal short circuit or exciter field fault. VR4 regulators include an overcurrent shutoff to protect generator components. If the unit operates for an extended period of time at low rpm, the overcurrent shutoff may trip. It will reset automatically when the generator is completely shutoff. The approximate recommended minimum operating speed is: Four pole generator ... 1200 rpmSix pole generator ... 750 rpm
Cat SIS web machinery list:
Parts cover Caterpillar catalog:
4K0413
COVER
611, 613C, 613C II, 615, 615C, 623, 623B, 623E, 633C, 814, 814B, 814S, 815, 815B, 825C, 844, 936, 936F, 950, 950B, 950B/950E, D25C, D25D, D30C, D350C, D350E, D35C, D35HP, D400, D400E, D40D, D8L, G936
611, 613C, 613C II, 615, 615C, 623, 623B, 623E, 633C, 814, 814B, 814S, 815, 815B, 825C, 844, 936, 936F, 950, 950B, 950B/950E, D25C, D25D, D30C, D350C, D350E, D35C, D35HP, D400, D400E, D40D, D8L, G936
2S5838
COVER ASSEM.
120G, 12G, 130G, 140G, 160G, 621, 980B
120G, 12G, 130G, 140G, 160G, 621, 980B
6K6759
COVER ASSEM.
518, 930, 930R
518, 930, 930R
5K5933
COVER ASSEM.
518, 528, 613, 613B, 814, 815, 950, 966C
518, 528, 613, 613B, 814, 815, 950, 966C
6K8469
COVER ASSEM.
518, 910, 920
518, 910, 920
6N7697
COVER (compressor)
621R, 815B, 966D, 972G, 980B
621R, 815B, 966D, 972G, 980B
4K7426
COVER
815, 936, 936F, 950, 966C, 966R, G936
815, 936, 936F, 950, 966C, 966R, G936
7K1512
COVER
824C, 980, 980B, 980C, 980F, R1700 II
824C, 980, 980B, 980C, 980F, R1700 II
5K0609
COVER
525B, 528, 528B, 530B, 533, 535B, 543, 545, 814, 815, 824C, 826C, 950, 966C, 980C, 980F, HA770, HA771, HA870, HA871, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700 II, R1700G, TK370, TK371, TK...
525B, 528, 528B, 530B, 533, 535B, 543, 545, 814, 815, 824C, 826C, 950, 966C, 980C, 980F, HA770, HA771, HA870, HA871, R1300, R1300G, R1300G II, R1600, R1600G, R1600H, R1700 II, R1700G, TK370, TK371, TK...
5K3493
COVER
814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 950B, 950B/950E, 950F, 950F II, 960F, 966D, 966F, 966F II, 970F, 980, 980B
814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 950B, 950B/950E, 950F, 950F II, 960F, 966D, 966F, 966F II, 970F, 980, 980B
4K7251
COVER
814, 815, 816, 950, 966C, 966R
814, 815, 816, 950, 966C, 966R
4K6735
COVER (UPPER)
814, 815, 816, 966C
814, 815, 816, 966C
4D5558
COVER
651, 657
651, 657
7D8839
COVER
650B, 657B
650B, 657B
7D6426
COVER ASSEM.
657B
657B
9S2420
COVER
631C, 824B, 834
631C, 824B, 834
5J4575
COVER
637, 637B, 637D, 639D, 793C, 793D
637, 637B, 637D, 639D, 793C, 793D
9S1986
COVER
631C, 988
631C, 988
3D9262
COVER ASSEM.
650B, 666, 666B
650B, 666, 666B
3D9261
COVER ASSEM.
650B, 666, 666B
650B, 666, 666B
4D1526
COVER ASSEM.
650B, 666, 666B
650B, 666, 666B
5S7921
COVER ASSEM.
641B, 650B
641B, 650B