AVSPARE.COM
parts catalog

COVER, MANHOLE B092060 - Caterpillar



B092060 COVER, MANHOLE Caterpillar parts PS-130, PS-180 COVER
Rating:
23
Alternative (cross code) number:
CAB092060
B09-2060
B092060
Caterpillar B092060 COVER, MANHOLE

Buy COVER, MANHOLE B092060 Caterpillar genuine, new aftermarket tractor parts with delivery
PNEUMATIC COMPACTOR,

Compatible equipment models: B092060:

PNEUMATIC COMPACTOR  PS-130   PS-180   Caterpillar
Number on catalog scheme: 36
 
  For full view, you need register

Information:


Illustration 1 g01137536
Schematic of the Boom Cylinder Extend SolenoidThis diagnostic code is associated with the boom cylinder extend solenoid. The FMI 13 means that the ECM has determined that the solenoid needs calibration. Once the calibration for the Boom Cylinder Extend Solenoid has been performed successfully, this diagnostic code will disappear. This diagnostic code is active on a new ECM.Possible causes of this diagnostic code are listed:
The solenoid has failed.
The ECM has been replaced or new software has been installed.
The ECM has failed.System Response:Note: Ensure that you have repaired any condition that would cause other active diagnostic codes that are related to this solenoid. For example, the CID 1193 FMI 03 or FMI 05 are not active when the CID 1193 FMI 13 is active. If the other diagnostic codes are active, troubleshoot those codes first. Then perform this procedure.Note: Ensure that the diagnostic code of CID 1193 FMI 13 is active before performing this procedure.Test Step 1. CHECK THE CALIBRATION
Perform the calibration procedure. Refer to the Testing and Adjusting section of the Service Manual for the correct procedure.
Observe the status of the CID 1193 FMI 13.Expected Result:The CID 1193 FMI 13 is active.Results:
YES - The CID 1193 FMI 13 is active. The diagnostic code has not been corrected. Verify that the correct software has been flashed into the ECM, or that the correct ECM is installed on the machine. Then repeat the calibration.Repair: If the diagnostic code is still active and the cause of the diagnostic code is not found replace the ECM. It is unlikely that the ECM has failed. Verify that the solenoid and associated circuits are correct before you replace the ECM. See Testing And Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 1193 FMI 13 is not active. The calibration corrected the condition that caused the diagnostic code. Repair: Resume normal operation. Stop.

Caterpillar parts catalog:

Caterpillar parts catalog
PS-130 PNEUMATIC COMPACTOR 7ND00001-00120 (MACHINE)
PS-180 PNEUMATIC COMPACTOR 7PD00001-00044 (MACHINE)


Parts cover Caterpillar catalog:

7W2534 COVER GP-VALVE MECHANISM
206, 212, AP-800, CB-424, CS-323, PR-75, PS-110, PS-130, PS-180, WE-601B
2W7828 COVER GP-FRONT HOUSING
AP-800, CS-323, PR-75, PS-110, PS-130, PS-180, WE-601B
02007827 COVER
PS-110, PS-130, PS-180
E010116 COVER ASSY.
PS-110, PS-130, PS-180
E670486 COVER
PS-130, PS-180
56000394 COVER
PS-130, PS-180
56000394 COVER
PS-130, PS-180
E670486 COVER
PS-130, PS-180
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.