Information:
Illustration 1 g01361869
Schematic of the Screed Right Extender Out SolenoidThis diagnostic code is associated with the Screed Right Extender Out Solenoid. The FMI 03 means that the Implement ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Note: The Implement (Screed) ECM is located under the screed platform.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. System Response:When this diagnostic code is active, the following occurs:
Right extender will move to the fully extended position.
Operator station fault lamp is active.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness at the solenoid for the Right Extender Out hydraulic valve. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from contact J2-5 (wire K842-BU) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire K842-BU and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire K842-BU and socket at contact J2-5 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active CID 2557 FMI 03 diagnostic code.Expected Result:The CID 2557 FMI 03 diagnostic code is no longer active. A CID 2557 FMI 05 diagnostic code
Parts crank Caterpillar catalog:
0846907
CRANK
Caterpillar
Caterpillar
0845745
CRANK
Caterpillar
Caterpillar
0831282
CRANK
Caterpillar
Caterpillar
0816584
CRANK ARM
Caterpillar
Caterpillar
0804789
CRANK ASSY
Caterpillar
Caterpillar
0804533
CRANK ASSY
Caterpillar
Caterpillar
0935711
CRANK,LEVER
Caterpillar
Caterpillar
0932648
CRANK ASSY
Caterpillar
Caterpillar
0932507
CRANK ASSY
Caterpillar
Caterpillar
0932491
CRANK ASSY
Caterpillar
Caterpillar
0905547
CRANK A
Caterpillar
Caterpillar
0848764
CRANK
Caterpillar
Caterpillar