3F3840 CUP Caterpillar parts
25, 619
Rating:
Alternative (cross code) number:
CA3F3840
3F-3840
3F3840
CA3F3840
3F-3840
3F3840
Weight: 0.30 pounds 0 kg.
CABLE CONTROL,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Generic 3F3840 Taper Cup Bearing for Caterpillar
GENERIC Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || CT3F3840
GENERIC Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || CT3F3840
Information:
Note: Obtaining a Coolant Sample (Level 1) is optional if the cooling system is filled with Cat ELC (Extended Life Coolant). Cooling systems filled with Cat ELC should have a Coolant Sample (Level 2) obtained.Note: Obtain a Coolant Sample (Level 1) if the cooling system is filled with any other coolant instead of Cat ELC including the following coolants:
Commercial long life coolants that meet the Caterpillar Engine Coolant Specification -1 (Caterpillar EC-1)
Cat DEAC (Diesel Engine Antifreeze/Coolant)
Commercial heavy-duty coolant/antifreeze
Illustration 1 g06072526
(1) Cooling system sampling port
Table 1
Recommended Interval
Type of Coolant Level 1 Level 2
Cat DEAC Every 250 service hours Every year(1)
Conventional heavy duty-coolant
Commercial coolant that meets the requirements of the Caterpillar EC-1 standard
Cat ELC or conventional EC-1 coolant Optional Every year(1)
(1) The Level 2 Coolant Analysis should be performed sooner if a problem is suspected or identified.
Always use a designated pump for oil sampling, and use a separate designated pump for coolant sampling. Using the same pump for both types of samples may contaminate the samples that are being drawn. This contaminate may cause a false analysis and an incorrect interpretation that could lead to concerns by both dealers and customers.
Note: Level 1 results may indicate a need for Level 2 Analysis.Obtain the sample of the coolant as close as possible to the recommended sampling interval. To receive the full effect of S O S analysis, establish a consistent trend of data. To establish a pertinent history of data, perform consistent samplings that are evenly spaced. Supplies for collecting samples can be obtained from your Cat dealer.Use the following guidelines for proper sampling of the coolant:
Complete the information on the label for the sampling bottle before you begin to take the samples.
Keep the unused sampling bottles stored in plastic bags.
Obtain coolant samples directly from the coolant sample port. You should not obtain the samples from any other location.
Keep the lids on empty sampling bottles until you are ready to collect the sample.
Place the sample in the mailing tube immediately after obtaining the sample to avoid contamination.
Never collect samples from expansion bottles.
Never collect samples from the drain for a system.Submit the sample for Level 1 analysis.For additional information about coolant analysis, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" or consult your Cat dealer.
Commercial long life coolants that meet the Caterpillar Engine Coolant Specification -1 (Caterpillar EC-1)
Cat DEAC (Diesel Engine Antifreeze/Coolant)
Commercial heavy-duty coolant/antifreeze
Illustration 1 g06072526
(1) Cooling system sampling port
Table 1
Recommended Interval
Type of Coolant Level 1 Level 2
Cat DEAC Every 250 service hours Every year(1)
Conventional heavy duty-coolant
Commercial coolant that meets the requirements of the Caterpillar EC-1 standard
Cat ELC or conventional EC-1 coolant Optional Every year(1)
(1) The Level 2 Coolant Analysis should be performed sooner if a problem is suspected or identified.
Always use a designated pump for oil sampling, and use a separate designated pump for coolant sampling. Using the same pump for both types of samples may contaminate the samples that are being drawn. This contaminate may cause a false analysis and an incorrect interpretation that could lead to concerns by both dealers and customers.
Note: Level 1 results may indicate a need for Level 2 Analysis.Obtain the sample of the coolant as close as possible to the recommended sampling interval. To receive the full effect of S O S analysis, establish a consistent trend of data. To establish a pertinent history of data, perform consistent samplings that are evenly spaced. Supplies for collecting samples can be obtained from your Cat dealer.Use the following guidelines for proper sampling of the coolant:
Complete the information on the label for the sampling bottle before you begin to take the samples.
Keep the unused sampling bottles stored in plastic bags.
Obtain coolant samples directly from the coolant sample port. You should not obtain the samples from any other location.
Keep the lids on empty sampling bottles until you are ready to collect the sample.
Place the sample in the mailing tube immediately after obtaining the sample to avoid contamination.
Never collect samples from expansion bottles.
Never collect samples from the drain for a system.Submit the sample for Level 1 analysis.For additional information about coolant analysis, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" or consult your Cat dealer.
Caterpillar parts catalog:
Parts cup Caterpillar catalog:
1B3909
CUP-ROLLER BEARING
120, 120B, 12E, 140, 140B, 25, 550, 550B, 554, 560B, 570, 570B, 574, 580, 580B, 619, 65, 75C, 797, 834G, 834H, 836G, 836H, 844K, 854K, 85C, 988G, 988H, 990K, 992K, 993K, D8T, D9T, PR-450C
120, 120B, 12E, 140, 140B, 25, 550, 550B, 554, 560B, 570, 570B, 574, 580, 580B, 619, 65, 75C, 797, 834G, 834H, 836G, 836H, 844K, 854K, 85C, 988G, 988H, 990K, 992K, 993K, D8T, D9T, PR-450C
2F8508
CUP-BEARING
127, 16, 25, 3304, 3306, 508, 517, 518, 518C, 528, 528B, 530B, D315, D330A, D333A, D337, D342, D4HTSK II, D4HTSK III
127, 16, 25, 3304, 3306, 508, 517, 518, 518C, 528, 528B, 530B, D315, D330A, D333A, D337, D342, D4HTSK II, D4HTSK III
4F2041
CUP-BEARING
120B, 127, 12F, 140B, 143H, 14E, 163H, 163H NA, 24H, 25, 518, 527, 528, 528B, 530B, 589, 611, 613C, 613C II, 613G, 615, 615C, 619, 631C, 631E, 631G, 633C, 633E II, 637, 637D, 637E, 637G, 641, 641B, 65...
120B, 127, 12F, 140B, 143H, 14E, 163H, 163H NA, 24H, 25, 518, 527, 528, 528B, 530B, 589, 611, 613C, 613C II, 613G, 615, 615C, 619, 631C, 631E, 631G, 633C, 633E II, 637, 637D, 637E, 637G, 641, 641B, 65...
3F4210
CUP
127, 25, 518, 528
127, 25, 518, 528
1B6573
CUP
120B, 12E, 12F, 140, 16, 594, 594H, 621, 623B, 824, 824B, 825C, 826C, 980C, 980F, 988, 994, 994D, D35C, D35HP, D40D, D44B, D550B, D9G, D9H
120B, 12E, 12F, 140, 16, 594, 594H, 621, 623B, 824, 824B, 825C, 826C, 980C, 980F, 988, 994, 994D, D35C, D35HP, D40D, D44B, D550B, D9G, D9H
2S6401
CUP
571G, 572G, 983, 983B, D7F, D7G, D7G2, PM-565, PR-1000, PR-450, PR-450C
571G, 572G, 983, 983B, D7F, D7G, D7G2, PM-565, PR-1000, PR-450, PR-450C
3F4210
CUP
127, 25, 518, 528
127, 25, 518, 528
4M6967
CUP ASSEM.
12E, 955H
12E, 955H
8F3709
CUP
D8H, D8K, D9E
D8H, D8K, D9E
7N5482
CUP ASSEM.
816, 966C, D6D
816, 966C, D6D
8B6393
CUP
955K
955K
3A4525
CUP
955L
955L
3A4521
CUP
955L
955L
9S2581
CUP
D3
D3
8S2125
CUP
583K, D8H, D8K
583K, D8H, D8K