4T2864 CUTTING EDGE Caterpillar parts
Rating:
Alternative (cross code) number:
CA4T2864
4T-2864
4T2864
CA4T2864
4T-2864
4T2864
Weight: 253 pounds 114 kg.
Information:
ABRASION RESISTANT MATERIAL
N
BOLT HOLE SIZE
21
mm
CHAMFER
EDGE
HOLE PATTERN
CENTERLINE
HOLE SPACING
101.6
mm
LENGTH
2332.2
mm
NUMBER OF HOLES
23
THICKNESS
25
mm
TUNGSTEN CARBIDE
N
WIDTH
254
mm
Information:
Illustration 1 g02625798
Schematic of the "OTG Oil Temperature" sensorThis diagnostic code is recorded when the ECM reads the signal wire of the temperature sensor and the voltage is high. The possible causes of this diagnostic code are listed below:
A shorted harness
An open supply circuit to the sensor
A failed sensor
An open circuit
The ECM may have failed. This is unlikely.Note: Ensure that the diagnostic code is still active.Note: The following procedure can create numerous related diagnostic codes. Reconnect all harnesses. Then, the related diagnostic codes will be shown as being NOT active. Complete the following procedure. Then, clear all of the related diagnostic codes.Test Step 1. CHECK THE SUPPLY VOLTAGE AT THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Check the voltage at the machine harness connector of the sensor from contact A (sensor supply) to contact B (ground). Do NOT disconnect the sensor. Use the 7X-1710 Cable probes to measure the voltage. Expected Result:The voltage should measure approximately 8 DCV.Results:
OK - The voltage is approximately 5 DCV. The voltage is correct. Proceed to test step 3.
NOT OK - The voltage is not approximately 5 DCV. There is an open in the machine harness or the ECM has failed. It is unlikely that the ECM has failed. Proceed to test step 2.Test Step 2. CHECK FOR AN OPEN IN THE SUPPLY CIRCUIT.
The key start switch and the disconnect switch remain in the ON position.
Disconnect the sensor from the machine harness.
At the machine harness connector for the sensor, measure the voltage from contact A (sensor supply) to frame ground.Expected Result:The voltage measures approximately 5 DCV.Results:
OK - The voltage measures approximately 5 DCV. The return circuit is open. Proceed to test step 3.
NOT OK - The voltage does not measure approximately 8 DCV. The supply circuit is open.Repair: Repair the machine harness or
Parts cutting Caterpillar catalog:
4T2863
CUTTING EDGE
Caterpillar
Caterpillar
4T2862
CUTTING EDGE
Caterpillar
Caterpillar
4T2861
CUTTING EDGE
Caterpillar
Caterpillar
4T2860
CUTTING EDGE
Caterpillar
Caterpillar
4T2802
CUTTING EDGE
Caterpillar
Caterpillar
4T2334
CUTTING-EDGE
Caterpillar
Caterpillar
4T2955
CUTTING EDGE
Caterpillar
Caterpillar
4T2946
CUTTING EDGE
Caterpillar
Caterpillar
4T2890
CUTTING EDGE
Caterpillar
Caterpillar
4T2888
CUTTING EDGE
Caterpillar
Caterpillar
4T2867
CUTTING EDGE
Caterpillar
Caterpillar
4T2866
CUTTING EDGE
Caterpillar
Caterpillar