Information:
Illustration 1 g01435817
Connections of solenoid "B" on valve 1
Illustration 2 g01435819
Connections of solenoid "B" on valve 1This diagnostic code is associated with solenoid "B" on valve 1. The FMI 04 means that the valve ECM has determined that either an open in the circuit or a short to ground in the return circuit exists.The possible causes are listed:
The return circuit of the solenoid is shorted to ground.
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The valve ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2211 FMI 04 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Note: Check the configuration of your machine for the number of implement electronic control modules. The following table lists some of the configurations that are available:
Table 1
Machines with one Electronic Implement Control    
Electronic Implement Control 2     Fourth Valve, Ripper, or Winch    
Table 2
Machines with two Electronic Implement Controls    
Electronic Implement Control 2     Fourth Valve or Ripper    
Electronic Implement Control 3     Winch    Test Step 1. CHECK THE RETURN CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the solenoid from the machine harness.
Disconnect the machine harness at the valve ECM.
At the harness connector for the valve ECM, measure the resistance from the supply wire to all contacts that are used in the machine harness connector.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
YES - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NO - Each resistance measurement is NOT greater than 5000 ohms. There is a short in the machine harness between the supply wire and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
The key start switch and the disconnect switch remain in the OFF position.
The machine harness remains disconnected from the valve ECM.
The solenoid remains disconnected from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 to contact 2.
At the machine harness connector for the valve ECM, measure the resistance from the supply wire to the return wire.Expected Result:The resistance should be less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in the supply wire or the return wire of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK THE SOLENOID.
Remove the jumper wire from the previous Test
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cyl Caterpillar catalog:
4651711
CYL GP
Caterpillar
Caterpillar
4649559
CYL GP-
Caterpillar
Caterpillar
4649205
CYL GP
Caterpillar
Caterpillar
4649141
CYL GP
Caterpillar
Caterpillar
4649139
CYL GP
Caterpillar
Caterpillar
4613062
CYL GP-
Caterpillar
Caterpillar
4656234
CYL GP-
Caterpillar
Caterpillar
4656194
CYL GP-
Caterpillar
Caterpillar
4654238
CYL GP-
Caterpillar
Caterpillar
4653486
CYL GP-
Caterpillar
Caterpillar
4653485
CYL GP-
Caterpillar
Caterpillar
4652718
CYL GP
Caterpillar
Caterpillar