0019342 CYLINDER GR Caterpillar parts
Rating:
Alternative (cross code) number:
CA0019342
001-9342
0019342
CA0019342
001-9342
0019342
Weight: 16 pounds 7 kg.
Information:
Illustration 1 g01376238
Connections of the solenoid for spool out (12 pin ECM connection)
Illustration 2 g02719946
Connections of the solenoid for spool out (70 pin ECM connection)This diagnostic code is associated with the solenoid for reeling out the winch. The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The valve ECM has failed. This event is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1885 FMI 06 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The FMI 06 changes to an FMI05 after the solenoid is disconnected.Results:
YES - The FMI 06 changes to an FMI05 after the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the valve ECM.
At the machine harness connector, measure the resistance from the signal contact (wire F868-OR) to all contacts that are used in the machine harness connectors for the valve ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between the signal contact (wire F868-OR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the diagnostic code.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active. The diagnostic code has not been corrected.Repair: Check the circuit again.
Parts cylinder Caterpillar catalog:
0019117
CYLINDER
Caterpillar
Caterpillar
0018355
CYLINDER
Caterpillar
Caterpillar
0017960
CYLINDER
Caterpillar
Caterpillar
0017815
CYLINDER
Caterpillar
Caterpillar
0017801
CYLINDER
Caterpillar
Caterpillar
0017773
CYLINDER A
Caterpillar
Caterpillar
0024392
CYLINDER
Caterpillar
Caterpillar
0024290
CYLINDER
Caterpillar
Caterpillar
0022088
CYLINDER
Caterpillar
Caterpillar
0021269
CYLINDER
Caterpillar
Caterpillar
0020919
CYLINDER
Caterpillar
Caterpillar
0019915
CYLINDER
Caterpillar
Caterpillar