Illustration 1 g01731976
Connections of the starter relay
Illustration 2 g01693254
Typical starter relayThis diagnostic code is associated with the starter relay. The FMI 05 means that the ECM has determined that the current of the relay is below normal.The possible causes of this diagnostic code are listed below:
The energize circuit of the relay is open.
The return circuit of the relay is open.
The relay has failed.
The ECM has failed. This is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the circuit are clean and secure. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0444 FMI 05 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Note: The coil resistance of the start relay should measure 27.3 3 ohms at 20 °C (68.0 °F). Test Step 1. CHECK THE RELAY.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the start relay from the machine harness.
At the machine harness connector for the relay, place a jumper wire from contact 1 (wire 306-GN) to contact 2 (wire J764-BR).
Observe the status of the diagnostic code.Expected Result:The diagnostic code remains active. The FMI has not changed and the "FMI 05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The relay has failed.Repair: The relay has failed. Repeat this test in order to verify the failure of the relay. Replace the relay. Verify that the new relay corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector J2 from the ECM.
The jumper wire that was installed in the previous test step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-7 (wire 306-GN) to contact J2-8 (wire J764-BR).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There could be an open or a faulty connector in the machine harness.Repair: A resistance measurement that is more than 5.0 ohms but less than 5000 ohms may indicate a problem with one of the harness connectors in the circuit. A connector may be loose or corroded. Inspect the connectors that are in the circuit. Ensure that all of the connections are clean and secure.A measurement
Parts cylinder Caterpillar catalog:
0024290
CYLINDER
Caterpillar
Caterpillar
0022088
CYLINDER
Caterpillar
Caterpillar
0021269
CYLINDER
Caterpillar
Caterpillar
0020919
CYLINDER
Caterpillar
Caterpillar
0019915
CYLINDER
Caterpillar
Caterpillar
0019342
CYLINDER GR
Caterpillar
Caterpillar
0027844
CYLINDER
Caterpillar
Caterpillar
0027793
CYLINDER
Caterpillar
Caterpillar
0025777
CYLINDER
Caterpillar
Caterpillar
0025232
CYLINDER
Caterpillar
Caterpillar
0025132
CYLINDER
Caterpillar
Caterpillar
0024979
CYLINDER
Caterpillar
Caterpillar