10R9547 CYLINDER HEAD GP Caterpillar parts
621G, 623G, 627G, 735, 980G, C18, D8R II
Rating:
Alternative (cross code) number:
CA10R9547
10R-9547
10R9547
CA10R9547
10R-9547
10R9547
Weight: 432 pounds 196 kg.
ARTICULATED TRUCK, WHEEL TRACTOR,
Related part:
10R9547
HEAD GP-CYL -UTN
20R2647
R
You can buy:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
ALL STATES DP Cylinder Head Assembly Compatible with CAT 3406E/C15/C18 Acert 10R9547 10R9548 10R9549 223-7263 2237263
ALL STATES DP
ALL STATES DP
$2,399.00
20 Aug 2021
350.0[157.50] Pounds
US: YNG LLC.
CATERPILLAR CAT C15 ENGINE CYLINDER HEAD REMANUFACTURED MAGNAFLUXED -> 9918
Caterpillar BXS12400 176-9918 10R9547 10R9547 20R2648 20R2645 223-7263 223-9250 432-5470 243-6741 243-6741 183-5296 20R2646 222-1982 175-5329 176-9917 263-8280 234-5007 2239250 20R2648 318-0476 3180476 1604347 2454324 20R2645 162-0683 162-0623 1733366 1262047 176-9917 277-8240 / 2778240
Caterpillar BXS12400 176-9918 10R9547 10R9547 20R2648 20R2645 223-7263 223-9250 432-5470 243-6741 243-6741 183-5296 20R2646 222-1982 175-5329 176-9917 263-8280 234-5007 2239250 20R2648 318-0476 3180476 1604347 2454324 20R2645 162-0683 162-0623 1733366 1262047 176-9917 277-8240 / 2778240
Compatible equipment models: 10R9547:
Information:
Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. Each phase carrying the same load allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one-phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 2. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g03864546
Illustration 2 g00627416Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already presentIf a block load derating is required, refer to ISO 8528 Standards or SAE J1349 Standards.Power Factor
The power factor represents the efficiency of the load. The power factor is the ratio of apparent power to total power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors, solid-state controls, and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity. Solid-state controls (motor starters), variable frequency drivers, variable speed drivers, and UPS systems can operate at any power factor, leading, or lagging. In this case, the power factor can be between 0.4 and 1.0.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high-power factor will result in full engine load that is less than the generators rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Cat generators are designed for a power factor of 0.8 lagging. Consult your Cat dealer to check the generator rating if operation at less than 0.7 lagging power factor is desired.Excitation Systems
Self-Excited Generators
Self-excited generators receive excitation power and regulator-voltage sensing from the generators main armature output. The voltage regulator senses the generator output voltage. A
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. Each phase carrying the same load allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one-phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 2. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g03864546
Illustration 2 g00627416Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already presentIf a block load derating is required, refer to ISO 8528 Standards or SAE J1349 Standards.Power Factor
The power factor represents the efficiency of the load. The power factor is the ratio of apparent power to total power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors, solid-state controls, and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity. Solid-state controls (motor starters), variable frequency drivers, variable speed drivers, and UPS systems can operate at any power factor, leading, or lagging. In this case, the power factor can be between 0.4 and 1.0.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high-power factor will result in full engine load that is less than the generators rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Cat generators are designed for a power factor of 0.8 lagging. Consult your Cat dealer to check the generator rating if operation at less than 0.7 lagging power factor is desired.Excitation Systems
Self-Excited Generators
Self-excited generators receive excitation power and regulator-voltage sensing from the generators main armature output. The voltage regulator senses the generator output voltage. A
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
2237263
CYLINDER HEAD AS
24M, 3406E, 3456, 365C, 365C L, 365C L MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 5090B, 583T, 587T, 621G, 623G, 627F, 627G, 631D, 631G, 637G, 651B, 657B, 657E, 657G, 735, 740, 770, 772, 824C, 824G I...
24M, 3406E, 3456, 365C, 365C L, 365C L MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 5090B, 583T, 587T, 621G, 623G, 627F, 627G, 631D, 631G, 637G, 651B, 657B, 657E, 657G, 735, 740, 770, 772, 824C, 824G I...
2239250
CYLINDER HEAD GP
24M, 3406E, 3456, 365C, 365C L, 365C L MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 5090B, 583T, 587T, 621G, 623G, 627F, 627G, 631D, 631G, 637G, 651B, 657B, 657E, 657G, 735, 740, 770, 772, 824C, 824G I...
24M, 3406E, 3456, 365C, 365C L, 365C L MH, 385B, 385C, 385C FS, 385C L, 385C L MH, 5090B, 583T, 587T, 621G, 623G, 627F, 627G, 631D, 631G, 637G, 651B, 657B, 657E, 657G, 735, 740, 770, 772, 824C, 824G I...
1105096
CYLINDER HEAD AS
16G, 16H NA, 245D, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, D8R...
16G, 16H NA, 245D, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627F, 814B, 824C, 824G, 825C, 825G, 826C, 826G, 980C, 980F, 980F II, 980G, D350E, D400E, D40D, D8N, D8R, D8R...
1118181
CYLINDER GP-LIFT
980G, 980G II, 980H
980G, 980G II, 980H
1151371
CYLINDER GP-HYDRAULIC
345B II, 345B L, 345C, 345C L, 980G, 980G II, 980H
345B II, 345B L, 345C, 345C L, 980G, 980G II, 980H
1835296
CYLINDER HEAD GP
3406E, 3456, 385B, 5090B, 621G, 623G, 627G, 735, 740, 824G, 824G II, 825G II, 826G II, 834G, 836G, 980G, 980G II, 988G, AD30, AD55, C-15, C-16, C-18, C16, C18, D350E II, D400E II, D8R II, MTC835, R290...
3406E, 3456, 385B, 5090B, 621G, 623G, 627G, 735, 740, 824G, 824G II, 825G II, 826G II, 834G, 836G, 980G, 980G II, 988G, AD30, AD55, C-15, C-16, C-18, C16, C18, D350E II, D400E II, D8R II, MTC835, R290...
2635055
CYLINDER HEAD GP
24M, 3406E, 365C, 365C L, 365C L MH, 374D L, 374F L, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 583T, 587T, 621B, 621G, 623G, 627F, 627G, 631D, 631E, 631G, 633E II, 637D, 637E, 637G, 651B...
24M, 3406E, 365C, 365C L, 365C L MH, 374D L, 374F L, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 583T, 587T, 621B, 621G, 623G, 627F, 627G, 631D, 631E, 631G, 633E II, 637D, 637E, 637G, 651B...
2454324
CYLINDER HEAD AS
3406E, 3456, 385B, 621G, 623G, 627G, 735, 740, 824G, 824G II, 825G II, 826G II, 834G, 836G, 980G, 980G II, 988G, C-15, C-16, C-18, C16, C18, D350E II, D400E II, D8R II
3406E, 3456, 385B, 621G, 623G, 627G, 735, 740, 824G, 824G II, 825G II, 826G II, 834G, 836G, 980G, 980G II, 988G, C-15, C-16, C-18, C16, C18, D350E II, D400E II, D8R II
1125003
CYLINDER GP-TILT
980G, 980G II, 980H
980G, 980G II, 980H
1125004
CYLINDER GP-TILT
980G, 980G II, 980H
980G, 980G II, 980H
1118182
CYLINDER AS
980G, 980G II, 980H
980G, 980G II, 980H
1125068
CYLINDER AS
980G, 980G II, 980H
980G, 980G II, 980H
10R3198
CYLINDER HEAD AS
621G, 623G, 627G, 735, 980G, C15, C18, D8R II
621G, 623G, 627G, 735, 980G, C15, C18, D8R II
2590459
CYLINDER GP-HYDRAULIC
D3G, D4G, D5G
D3G, D4G, D5G
2590460
CYLINDER GP-ANGLING
315D L, D3G, D4G, D5G
315D L, D3G, D4G, D5G