1799709 CYLINDER & LINES GP-BOOM Caterpillar parts
307C
Rating:
Alternative (cross code) number:
CA1799709
179-9709
1799709
CA1799709
179-9709
1799709
MINI HYD EXCAVATOR,
Compatible equipment models: 1799709:
Information:
Removal Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Install a cap or a plug on all lines, hoses, wires, and tubes in order to prevent foreign materials from entering the system.
Evacuate the air conditioning system.
Illustration 1 g00623741
Loosen bolts (1), (2), and (3).
Illustration 2 g00623767
Loosen adjusting nuts (4). Move the refrigerant compressor in order to relieve the tension on belt (5). Remove belt (5).
Illustration 3 g00623769
Disconnect wiring harness (7). Remove the tie-wrap and disconnect wiring harness (8).
Disconnect two lines (6).
Remove bolts (1), (2), and (3). Remove refrigerant compressor (10). Installation Procedure
Illustration 4 g00623769
Put refrigerant compressor (10) in position. Install bolts (1), (2), and (3). Do not tighten bolts (1), (2), and (3).
Connect two lines (6).
Connect wiring harness (8) and install the tie-wrap. Connect wiring harness (7).
Illustration 5 g00623767
Install belt (5). Tighten adjusting nuts (4).
Illustration 6 g00623741
Tighten bolts (1), (2), and (3).
Charge the air conditioning system.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Install a cap or a plug on all lines, hoses, wires, and tubes in order to prevent foreign materials from entering the system.
Evacuate the air conditioning system.
Illustration 1 g00623741
Loosen bolts (1), (2), and (3).
Illustration 2 g00623767
Loosen adjusting nuts (4). Move the refrigerant compressor in order to relieve the tension on belt (5). Remove belt (5).
Illustration 3 g00623769
Disconnect wiring harness (7). Remove the tie-wrap and disconnect wiring harness (8).
Disconnect two lines (6).
Remove bolts (1), (2), and (3). Remove refrigerant compressor (10). Installation Procedure
Illustration 4 g00623769
Put refrigerant compressor (10) in position. Install bolts (1), (2), and (3). Do not tighten bolts (1), (2), and (3).
Connect two lines (6).
Connect wiring harness (8) and install the tie-wrap. Connect wiring harness (7).
Illustration 5 g00623767
Install belt (5). Tighten adjusting nuts (4).
Illustration 6 g00623741
Tighten bolts (1), (2), and (3).
Charge the air conditioning system.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
3030227
CYLINDER & SEAL GP-HYDRAULIC
307C, 307D, 308C, 308D
307C, 307D, 308C, 308D
1362463
CYLINDER AS
307B, 307C, 307D, 307E, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR
307B, 307C, 307D, 307E, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR
1884124
CYLINDER AS
307C
307C
2042719
CYLINDER AS
307C, 308C
307C, 308C
1838283
CYLINDER BLOCK GP
307C, 308C
307C, 308C