1838459 CYLINDER GP-TILT Caterpillar parts
315C, 315D L, D3G, D4G, D5G
Rating:
Alternative (cross code) number:
CA1838459
183-8459
1838459
CA1838459
183-8459
1838459
Weight: 53 pounds 24 kg.
Information:
BORE DIAMETER
88.9
mm
CLOSED LENGTH
482.6
mm
PIN SIZE CAP END
38.1
mm
PIN SIZE ROD EYE
38.1
mm
ROD DIAMETER
38.1
mm
STROKE
148
TYPE
THD CROWN
EXCAVATOR, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 1838459 Ripper Tilt Hydraulic Cylinder Group for Model 315C/315D L/D3G/D4G/D5G
CTP For Model 315C/315D L/D3G/D4G/D5G || Sold in each || Easy in-and-out fit
CTP For Model 315C/315D L/D3G/D4G/D5G || Sold in each || Easy in-and-out fit
CTP 1838459 Ripper Tilt Hydraulic Cylinder Group for Model 315C/315D L/D3G/D4G/D5G
CTP For Model 315C/315D L/D3G/D4G/D5G || Sold in each || Easy in-and-out fit
CTP For Model 315C/315D L/D3G/D4G/D5G || Sold in each || Easy in-and-out fit
Compatible equipment models: 1838459:
Information:
Conditions Which Generate This Code:
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
K1     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the "K7" relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0483 FMI 03 is an open circuit of the relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0483 FMI 03 is active.Note: The "DIAG" indicator will be flashing and the CID 0483 FMI 03 will be present on the display if the diagnostic code is active.Expected Result:A CID 0483 FMI 03 is displayed as an active diagnostic code or the diagnostic
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
K1     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the "K7" relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0483 FMI 03 is an open circuit of the relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0483 FMI 03 is active.Note: The "DIAG" indicator will be flashing and the CID 0483 FMI 03 will be present on the display if the diagnostic code is active.Expected Result:A CID 0483 FMI 03 is displayed as an active diagnostic code or the diagnostic
Caterpillar SIS machinery equipment:
Caterpillar SIS
D3G XL & LGP TRACK TYPE TRACTORS CFC00001-UP (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
D4G XL & LGP TRACK TYPE TRACTORS CFN00001-01071 (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
D5G XL & LGP TRACK TYPE TRACTORS FDH00001-UP (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
D3G XL & D3G LGP Track-Type Tractors BYR00001-UP (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
D4G XL & D4G LGP Track-Type Tractors HYD00001-UP (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
D5G XL & D5G LGP Track-Type Tractors RKG00001-UP (MACHINE) POWERED BY 3046 Engine »
183-8459
CYLINDER GP-TILT
315D L SUPPLEMENT FOR EXCAVATOR /PAT BLADE/ CJN00001-UP (MACHINE) »
183-8459
CYLINDER GP-TILT
315C L SUPPLEMENT FOR EXCAVATOR /PAT BLADE/ CJC00001-UP (MACHINE) »
183-8459
CYLINDER GP-ANGLING HYDRAULIC
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
2167388
CYLINDER GP-ANGLING
D3G, D4G, D5G
D3G, D4G, D5G
2590459
CYLINDER GP-HYDRAULIC
D3G, D4G, D5G
D3G, D4G, D5G
7Y1780
CYLINDER
311, 311B, 311C, 312, 312B, 315, 315B, 315B L, 315C, 315D L, 317, 320 L, OEMS
311, 311B, 311C, 312, 312B, 315, 315B, 315B L, 315C, 315D L, 317, 320 L, OEMS
1453030
CYLINDER
315C, 318C, 319C, 320C, 320C L, 321C
315C, 318C, 319C, 320C, 320C L, 321C
2394392
CYLINDER
315D L, 318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 ...
315D L, 318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 ...
1838643
CYLINDER AS
315C, 315D L, D3G, D4G, D5G
315C, 315D L, D3G, D4G, D5G
2300594
CYLINDER AS
315C, 315D L
315C, 315D L
2300598
CYLINDER AS
315C, 315D L
315C, 315D L
1124297
CYLINDER AS
931C II, 933, 933C, D3C, D3C II, D3C III, D3G, D4C II, D4C III, D4G, PM-201, PM-565, PM-565B
931C II, 933, 933C, D3C, D3C II, D3C III, D3G, D4C II, D4C III, D4G, PM-201, PM-565, PM-565B
1833722
CYLINDER AS
D3G, D4G, D5G
D3G, D4G, D5G
1920892
CYLINDER AS
D3G, D4G, D5G
D3G, D4G, D5G
1920894
CYLINDER AS
D3G, D4G, D5G
D3G, D4G, D5G
2802800
CYLINDER & LINES GP-FELLING HD
HF201, HF221
HF201, HF221
2525213
CYLINDER GP-TILT
990 II, 990H, 990K
990 II, 990H, 990K
1459897
CYLINDER GP-TILT
990 II
990 II
1988305
CYLINDER GP-ARTICULATION
120H, 135H
120H, 135H
1931475
CYLINDER & MTG GP-ARTICULATION
120H, 135H
120H, 135H
2603646
CYLINDER & MTG GP-BLADE TIP
14H, 14M, 16H, 16M
14H, 14M, 16H, 16M