3741857 CYLINDER GP-BLADE Caterpillar parts
307D, 307E, 308E
Rating:
Alternative (cross code) number:
CA3741857
374-1857
3741857
CA3741857
374-1857
3741857
Weight: 127 pounds 57 kg.
MINI HYD EXCAVATOR,
Information:
Menu D - Display Menu
Input and output values are displayed once when each item is selected. To get a continuous update, hold down the up or down arrow. Descriptions of each menu item follow.1. Engine Speed displays the current engine speed in rpm.2. Speed Reference displays the current speed reference in rpm. Note that this may not be the speed the engine is currently running at due to the effect of idle droop, fuel limiters, etc.3. Actuator Output displays the current percent of output. Maximum (100%) is 200 mA (0 mA for reverse-acting). This is useful for setup of the control fuel limiters, torque limiter, idle droop, and gain breakpoint settings.4. Aux Output displays the milliamps on the Aux Output. This is useful for testing and system calibration.5. Remote Input displays the milliamps on the Remote Speed Setting Input. This is useful for testing and system calibration.6. Aux Input displays the voltage on the Aux Input.7. Run/Stop Switch Status displays the status of discrete input A, terminal 9. Closed indicates 24 Vdc is applied to the input selecting the run position. Open selects minimum fuel or the stop position.8. Idle/Rated Switch Status displays the status of discrete input B, terminal 10. Closed indicates 24 Vdc is applied to the input selecting rated speed and the maximum fuel limit and the torque limit. Open indicates idle and the start fuel limit are selected.9. Lower Switch Status displays the status of discrete input C, terminal 11. Closed indicates 24 Vdc is applied to the input selecting lower speed (or remote speed setting if the Raise switch is also closed).10. Raise Switch Status displays the status of discrete input D, terminal 12. Closed indicates 24 Vdc is applied to the input selecting raise speed (or remote speed setting if the Lower switch is also closed).
Figure 4-6a. Torque Limit Setup Example (standard models)
Figure 4-6b. Six-Breakpoint Torque Limiter (9905-457)11. Local/Remote Switch Status displays the status of both discrete inputs C and D, terminals 11 and 12. Selecting both Raise and Lower places the control in the remote speed setting mode where the 4-20 mA Remote Speed Setting Input is used for the speed reference.12. Alternate Dynamics Switch Status displays the status of discrete input E, terminal 13. Closed indicates 24 Vdc is applied to the input selecting the alternate dynamics (dynamics 2).13. Failed Speed Override Switch Status displays the status of discrete input F, terminal 14. Closed indicates 24 Vdc is applied to the input selecting to override the function of the failed speed detection which provides for moving fuel to minimum position when no speed signal is detected by the control.14. Watchdog Status displays the status of the control CPU. The normal status displayed is CPU OK. If a CPU fault occurs, the CPU OK indicator on the front of the control will turn off, the Actuator Output and Aux Output will decrease to minimum output, and the Watchdog Status will display TIME OUT. To reset the watchdog, turn off power to
Input and output values are displayed once when each item is selected. To get a continuous update, hold down the up or down arrow. Descriptions of each menu item follow.1. Engine Speed displays the current engine speed in rpm.2. Speed Reference displays the current speed reference in rpm. Note that this may not be the speed the engine is currently running at due to the effect of idle droop, fuel limiters, etc.3. Actuator Output displays the current percent of output. Maximum (100%) is 200 mA (0 mA for reverse-acting). This is useful for setup of the control fuel limiters, torque limiter, idle droop, and gain breakpoint settings.4. Aux Output displays the milliamps on the Aux Output. This is useful for testing and system calibration.5. Remote Input displays the milliamps on the Remote Speed Setting Input. This is useful for testing and system calibration.6. Aux Input displays the voltage on the Aux Input.7. Run/Stop Switch Status displays the status of discrete input A, terminal 9. Closed indicates 24 Vdc is applied to the input selecting the run position. Open selects minimum fuel or the stop position.8. Idle/Rated Switch Status displays the status of discrete input B, terminal 10. Closed indicates 24 Vdc is applied to the input selecting rated speed and the maximum fuel limit and the torque limit. Open indicates idle and the start fuel limit are selected.9. Lower Switch Status displays the status of discrete input C, terminal 11. Closed indicates 24 Vdc is applied to the input selecting lower speed (or remote speed setting if the Raise switch is also closed).10. Raise Switch Status displays the status of discrete input D, terminal 12. Closed indicates 24 Vdc is applied to the input selecting raise speed (or remote speed setting if the Lower switch is also closed).
Figure 4-6a. Torque Limit Setup Example (standard models)
Figure 4-6b. Six-Breakpoint Torque Limiter (9905-457)11. Local/Remote Switch Status displays the status of both discrete inputs C and D, terminals 11 and 12. Selecting both Raise and Lower places the control in the remote speed setting mode where the 4-20 mA Remote Speed Setting Input is used for the speed reference.12. Alternate Dynamics Switch Status displays the status of discrete input E, terminal 13. Closed indicates 24 Vdc is applied to the input selecting the alternate dynamics (dynamics 2).13. Failed Speed Override Switch Status displays the status of discrete input F, terminal 14. Closed indicates 24 Vdc is applied to the input selecting to override the function of the failed speed detection which provides for moving fuel to minimum position when no speed signal is detected by the control.14. Watchdog Status displays the status of the control CPU. The normal status displayed is CPU OK. If a CPU fault occurs, the CPU OK indicator on the front of the control will turn off, the Actuator Output and Aux Output will decrease to minimum output, and the Watchdog Status will display TIME OUT. To reset the watchdog, turn off power to
Caterpillar SIS machinery equipment:
Caterpillar SIS
308 SR Mini Hydraulic Excavator GK800001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
307.5 Mini Hydraulic Excavator GW700001-UP (MACHINE) POWERED BY C2.4 Engine »
374-1857
CYLINDER GP-BLADE
309 CR Mini Hydraulic Excavator GG900001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
309 CR Mini Hydraulic Excavator GW900001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
308 CR Mini Hydraulic Excavator GX800001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
308 CR Mini Hydraulic Excavator GG800001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
308 CR Mini Hydraulic Excavator GW800001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
308.5 Mini Hydraulic Excavator GZ800001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
307D Mini Hydraulic Excavator WZX00001-UP (MACHINE) »
374-1857
CYLINDER GP-BLADE
308E Mini Hydraulic Excavator TAZ00001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
307E Mini Hydraulic Excavator H1Y00001-UP (MACHINE) POWERED BY C2.6 Engine »
374-1857
CYLINDER GP-BLADE
307E2 Mini Hydraulic Excavator KC900001-UP (MACHINE) POWERED BY C2.4 Engine »
374-1857
CYLINDER GP-BLADE
307E2 Mini Hydraulic Excavator CE200001-UP (MACHINE) POWERED BY C2.6 Engine »
374-1857
CYLINDER GP-BLADE
308E2 Mini Hydraulic Excavator F8C00001-UP (MACHINE) POWERED BY C3.3B Engine »
374-1857
CYLINDER GP-BLADE
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
3741856
CYLINDER GP-BUCKET
307C, 307D, 307E
307C, 307D, 307E
2898090
CYLINDER & LINES GP
315D L, 318D2 L
315D L, 318D2 L
1183956
CYLINDER & LINES GP-BOOM
320B, 320B FM LL, 320B U
320B, 320B FM LL, 320B U
1183955
CYLINDER & SEAL GP-STICK
320B, 320B FM LL, 320B U
320B, 320B FM LL, 320B U
3042044
CYLINDER & MTG GP-STEERING
CP-44, CS-44
CP-44, CS-44
1081150
CYLINDER & MTG GP-RIPPER
D5M, D5N
D5M, D5N
3056780
CYLINDER & LINES GP-THUMB
307D, 308D, 308E2 CR
307D, 308D, 308E2 CR
1U3165
CYLINDER GP-TILT
910, 931B, G910
910, 931B, G910
4361938
CYLINDER HEAD GP
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
4N1201
CYLINDER BLOCK GP
3412, 3412C, 651E, 657E, 772B, 773B, 775B, 990, 992C, 992D, D10N, D9L, G3412, PM3412, PR-1000, PR-750B
3412, 3412C, 651E, 657E, 772B, 773B, 775B, 990, 992C, 992D, D10N, D9L, G3412, PM3412, PR-1000, PR-750B