AVSPARE.COM
parts catalog

CYLINDER A. 3K1367 - Caterpillar


3K1367 CYLINDER A. Caterpillar parts
Rating:
41
Alternative (cross code) number:
CA3K1367
3K-1367
3K1367
Caterpillar 3K1367 CYLINDER A.
Weight: 3 pounds 1 kg.

Buy CYLINDER A. 3K1367 Caterpillar genuine, new aftermarket tractor parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$134.04

05 Nov 2024

US: Alpha Omega Mac
Generic 3K1367 Wheel Cylinder for Mitsubishi
GENERIC Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || MB3K1367
$134.04

05 Nov 2024

US: Alpha Omega Mac
Generic 3K1367 Wheel Cylinder for Caterpillar
GENERIC Please Note That Some Listings Use Stock Images As A Reference For Customers note that all OEM part numbers and logos are to be used for identification purposes only || CT3K1367
$51.15
 

05 Aug 2020
3.9021820374[1.35] Pounds
-: -
CTP Caterpillar Cylinder a (3k1367)
  For full view, you need register

Information:

Use this procedure to troubleshoot the ground level shutdown switch or the following diagnostic codes:
Table 1
Diagnostic Trouble Codes for the Ground Level Shutdown Switch
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
4215-3 267-3 Remote Shutdown Input voltage above normal The Electronic Control Module (ECM) detects the following condition:
Both contacts from the ground level shutdown switch are in the open state.
4215-4 267-4 Remote Shutdown Input voltage below normal The Electronic Control Module (ECM) detects the following conditions:
Both contacts from the ground level shutdown switch are in the closed state. The ground level shutdown switch allows the engine to be stopped from ground level. When the switch is moved to the STOP position, the engine shuts down. The ECM remains powered. The ground level shutdown switch must be in the RUN position and the power to the ECM must be cycled before the engine can restart.
Illustration 1 g06155904
Schematic for the ground level shutdown switch
Illustration 2 g02656956
Ground level shutdown switch connector
(1) Ground level shutdown switch (N/O)
(2) Switch ground
(3) Ground level shutdown switch (N/C)
Illustration 3 g02657016
Pin locations on the P1 connector for the ground level shutdown switch.
(5) Ground level shutdown switch return
(40) Ground level shutdown switch (N/O)
(41) Ground level shutdown switch (N/C)Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the terminal connections on the P1 ECM connector and the switch connector.
Refer to Troubleshooting, "Electrical Connector - Inspect".
B. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the ground level shutdown switch connector.
C. Check the screw for the ECM connector for the correct torque of 5 N m (44 lb in).
D. Check the harness for corrosion, abrasion, and pinch points from the solenoids to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Place the ground level shutdown switch in the RUN position.
D. Turn the keyswitch to the ON position. Wait at least 20 seconds for activation of the diagnostic codes.
E. Verify if any of the diagnostic codes that are listed in Table 1 are active.
F. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: No diagnostic codes are active or logged.
Repair: The switch is operating normally. There may be an intermittent fault in the wiring harness or in a connector. Check the wiring harness and the connectors for an intermittent electrical fault. Refer to Troubleshooting, "Electrical Connector - Inspect".
Result: A 4215-3 (267-3) diagnostic is


Parts cylinder Caterpillar catalog: