5205009 CYLINDER & LINES GP-BUCKET Caterpillar parts
Rating:
Alternative (cross code) number:
CA5205009
520-5009
5205009
CA5205009
520-5009
5205009
Weight: 116 pounds 52 kg.
Information:
Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap.
Illustration 1 g03890108
Typical example
Remove drain plug (1) on the engine. Open the drain cock or remove the drain plug on the radiator.Allow the coolant to drain.
Refer to OEM for the drain location for your application.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Cat dealer or consult Dealer Service Tools.Drain Plugs for Factory Installed Radiators
Illustration 2 g06164641
Typical example
(2) C1.7 Three cylinder radiator drain plug
(3) C2.2 Four cylinder turbocharged engine radiator drain plug
(4) C2.2 Four cylinder turbocharged aftercooled engine drain plug front of radiator
Tighten drain plug (2) to a torque of 4 N m (35.4 lb in)
Tighten drain plug (3) to a torque of 4 N m (35.4 lb in)
Tighten drain plug (4) to a torque of 6 N m (53. lb in)Flush
Flush the cooling system with clean water to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with clean water. Install the cooling system filler cap.
Start and run the engine at low idle until the temperature reaches 49 °C to 66 °C (120 °F to 150 °F).
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.Fill
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with Extended Life Coolant (ELC). Refer to this Operation and Maintenance Manual, "Refill Capacities and Recommendations" topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to high idle. Run the engine at high idle for 1 minute to purge the air from the cavities of the engine block. Stop the engine.
Maintain the coolant
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap.
Illustration 1 g03890108
Typical example
Remove drain plug (1) on the engine. Open the drain cock or remove the drain plug on the radiator.Allow the coolant to drain.
Refer to OEM for the drain location for your application.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Cat dealer or consult Dealer Service Tools.Drain Plugs for Factory Installed Radiators
Illustration 2 g06164641
Typical example
(2) C1.7 Three cylinder radiator drain plug
(3) C2.2 Four cylinder turbocharged engine radiator drain plug
(4) C2.2 Four cylinder turbocharged aftercooled engine drain plug front of radiator
Tighten drain plug (2) to a torque of 4 N m (35.4 lb in)
Tighten drain plug (3) to a torque of 4 N m (35.4 lb in)
Tighten drain plug (4) to a torque of 6 N m (53. lb in)Flush
Flush the cooling system with clean water to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with clean water. Install the cooling system filler cap.
Start and run the engine at low idle until the temperature reaches 49 °C to 66 °C (120 °F to 150 °F).
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.Fill
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with Extended Life Coolant (ELC). Refer to this Operation and Maintenance Manual, "Refill Capacities and Recommendations" topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to high idle. Run the engine at high idle for 1 minute to purge the air from the cavities of the engine block. Stop the engine.
Maintain the coolant
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
5198850
CYLINDER GP-VARIABLE ADJ BOOM
Caterpillar
Caterpillar
5189056
CYLINDER & LINES GP-BOOM
Caterpillar
Caterpillar
5189055
CYLINDER & LINES GP-BOOM
Caterpillar
Caterpillar
5161006
CYLINDER & LINES GP-STICK
Caterpillar
Caterpillar
5161003
CYLINDER & SEAL GP-BOOM
Caterpillar
Caterpillar
5160434
CYLINDER GP-LIFT
Caterpillar
Caterpillar
5240077
CYLINDER & LINES GP-STICK
Caterpillar
Caterpillar
5240076
CYLINDER & LINES GP-STICK
Caterpillar
Caterpillar
5240075
CYLINDER & LINES GP-BOOM
Caterpillar
Caterpillar
5240074
CYLINDER & LINES GP-BOOM
Caterpillar
Caterpillar
5226149
CYLINDER GP-HYDRAULIC
Caterpillar
Caterpillar
5212883
CYLINDER GP-BUCKET
Caterpillar
Caterpillar