5218391 CYLINDER GP-RIPPER Caterpillar parts
Rating:
Alternative (cross code) number:
CA5218391
521-8391
5218391
CA5218391
521-8391
5218391
Weight: 298 pounds 135 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
PTO Clutch Crankshaft Bolt for Exmark Toro 5218-408 1423587 1355267 5218408 142-3588 135-1307 5218-391 142-3682 5218-423 5218-422
HD Switch This is a Premium 7/16-20 Grade 5 Crankshaft Bolt used for clutch installation || Note: It is recommended that clutch bolts are replaced when the clutch is replaced or installed. || We recommend using a medium strength lock-tite thread locker when installing. || Important Note: Torque this bolt to 50-55 ftlbs When Installing clutch.
HD Switch This is a Premium 7/16-20 Grade 5 Crankshaft Bolt used for clutch installation || Note: It is recommended that clutch bolts are replaced when the clutch is replaced or installed. || We recommend using a medium strength lock-tite thread locker when installing. || Important Note: Torque this bolt to 50-55 ftlbs When Installing clutch.
$427.82
23 Nov 2023
US: GoodStuff Shop
WILD LOTION for ~Warner Electric PTO Clutch, 5218-391, 135-1307
WILD LOTION For ~Warner Electric PTO Clutch, 5218-391, 135-1307 || for warner electric pto clutch, 5218391, 1351307: || designed for durability and dependability || long service life in extremely harsh conditions || Keep your tools running smoothly. Find high-quality replacement parts for outdoor power tools
WILD LOTION For ~Warner Electric PTO Clutch, 5218-391, 135-1307 || for warner electric pto clutch, 5218391, 1351307: || designed for durability and dependability || long service life in extremely harsh conditions || Keep your tools running smoothly. Find high-quality replacement parts for outdoor power tools
Information:
Event/Diagnostic Report Interval (SMU)
The Event/Diagnostic Report Interval determines how soon the Product Link will report a reoccurrence of an event or diagnostic code. The SMU in the description signifies that this value is measured in units of machine operating hours. The minimum value is 4 hours. The default is 20 hours, meaning that an event/diagnostic update message will not be resent for a specific event/diagnostic until the machine has operated for 20 hours after the last transmitted occurrence of that event/diagnostic. At the next event/diagnostic occurence after the time period elapses, another message will be sent. This helps to reduce the number of messages sent for a given event/diagnostic thereby reducing the messaging cost. All events/diagnostics are recorded and may be viewed with the Electronic Technician.
Illustration 1 g00663456
To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 1.Event/Diagnostic Message Interval (RT)
This value is only valid if the event or diagnostic report intervals are set to Next Scheduled. The Event/Diagnostic Message Interval sets the time period before an event or diagnostic message update is sent. This time period is calculated from the "Report Start Time". The RT in the description signifies that this value is measured in units of real time (or calendar) hours. The minimum value is 24 hours. The default is 168 hours. This means that an event/diagnostic scheduled message will be every 168 hours (1 week) if any Event/Diagnostic code has occurred since the last scheduled mesage was sent. This helps to reduce the number of messages sent, thereby reducing the messaging cost.
Illustration 2 g00663453
To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 2.Report Start Time
The standard reports for Product Link are sent at time-based intervals. Position reports are sent every six hours and a service meter report or fuel report is sent every 24 hours. The report start time is used as the initial report time for calculating when subsequent reports are sent. The report start time is also used as the basis for calculating "Next Scheduled" events and diagnostic messages. SMU reports and fuel reports will alternate days. The transmissions are automatically optimized for maximum efficiency of the Product Link system, and the messages may not arrive on an exact hourly schedule. The messages will arrive very close to the scheduled time.Note: The time entered must be in Greenwich Mean Time (GMT). In order to convert your local time to GMT, you must add a certain number of hours. In the eastern time zone, add 5 hours to your local time. In the central time zone, add six hours to your local time. For example, if you want the report to arrive at 5:00 A.M. in the central time zone, enter 11:00 A.M. for the report start time. If daylight savings time is currently being observed, then add one more hour.
Illustration
The Event/Diagnostic Report Interval determines how soon the Product Link will report a reoccurrence of an event or diagnostic code. The SMU in the description signifies that this value is measured in units of machine operating hours. The minimum value is 4 hours. The default is 20 hours, meaning that an event/diagnostic update message will not be resent for a specific event/diagnostic until the machine has operated for 20 hours after the last transmitted occurrence of that event/diagnostic. At the next event/diagnostic occurence after the time period elapses, another message will be sent. This helps to reduce the number of messages sent for a given event/diagnostic thereby reducing the messaging cost. All events/diagnostics are recorded and may be viewed with the Electronic Technician.
Illustration 1 g00663456
To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 1.Event/Diagnostic Message Interval (RT)
This value is only valid if the event or diagnostic report intervals are set to Next Scheduled. The Event/Diagnostic Message Interval sets the time period before an event or diagnostic message update is sent. This time period is calculated from the "Report Start Time". The RT in the description signifies that this value is measured in units of real time (or calendar) hours. The minimum value is 24 hours. The default is 168 hours. This means that an event/diagnostic scheduled message will be every 168 hours (1 week) if any Event/Diagnostic code has occurred since the last scheduled mesage was sent. This helps to reduce the number of messages sent, thereby reducing the messaging cost.
Illustration 2 g00663453
To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 2.Report Start Time
The standard reports for Product Link are sent at time-based intervals. Position reports are sent every six hours and a service meter report or fuel report is sent every 24 hours. The report start time is used as the initial report time for calculating when subsequent reports are sent. The report start time is also used as the basis for calculating "Next Scheduled" events and diagnostic messages. SMU reports and fuel reports will alternate days. The transmissions are automatically optimized for maximum efficiency of the Product Link system, and the messages may not arrive on an exact hourly schedule. The messages will arrive very close to the scheduled time.Note: The time entered must be in Greenwich Mean Time (GMT). In order to convert your local time to GMT, you must add a certain number of hours. In the eastern time zone, add 5 hours to your local time. In the central time zone, add six hours to your local time. For example, if you want the report to arrive at 5:00 A.M. in the central time zone, enter 11:00 A.M. for the report start time. If daylight savings time is currently being observed, then add one more hour.
Illustration
Caterpillar SIS machinery equipment:
Caterpillar SIS
D9R Track-Type Tractor HWH00001-UP (MACHINE) POWERED BY 3408C Engine »
521-8391
CYLINDER GP-RIPPER
DV232 Track Type Tractor NJH00001-UP (MACHINE) POWERED BY C18 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Power Shift 8BL00830-01052 (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Differential Steering 7TL00557-00851 (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Power Shift 8BL01053-UP (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Differential Steering 7TL00852-UP (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Differential Steering ABK00001-UP (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R Track-Type Tractor Power Shift ACL00001-UP (MACHINE) POWERED BY 3408 Engine »
521-8391
CYLINDER GP-RIPPER
D9R TRACK-TYPE TRACTOR JJB00001-UP (MACHINE) POWERED BY 3408C Engine »
521-8391
CYLINDER GP-RIPPER
D9T Track-Type Tractor RJS00001-UP (MACHINE) POWERED BY C18 Engine »
521-8391
CYLINDER GP-RIPPER
D9R TRACK-TYPE TRACTOR WDM00001-UP (MACHINE) POWERED BY 3408C Engine »
521-8391
CYLINDER GP-RIPPER
D9T TRACK-TYPE TRACTOR TWG00001-UP (MACHINE) POWERED BY C18 Engine »
521-8391
CYLINDER GP-RIPPER
D9T TRACK-TYPE TRACTOR REX00001-UP (MACHINE) POWERED BY C18 Engine »
521-8391
CYLINDER GP-RIPPER
Caterpillar parts catalog:
Parts cylinder Caterpillar catalog:
5218390
CYLINDER GP-RIPPER
Caterpillar
Caterpillar
5213762
CYLINDER GP-BULLDOZER LIFT
Caterpillar
Caterpillar
5213761
CYLINDER AS-LIFT
Caterpillar
Caterpillar
5212571
CYLINDER GP-RIPPER
Caterpillar
Caterpillar
5212570
CYLINDER AS
Caterpillar
Caterpillar
5205130
CYLINDER AS
Caterpillar
Caterpillar
5218401
CYLINDER AS-LIFT
Caterpillar
Caterpillar
5218398
CYLINDER AS
Caterpillar
Caterpillar
5218395
CYLINDER GP-RIPPER
Caterpillar
Caterpillar
5218394
CYLINDER GP-RIPPER
Caterpillar
Caterpillar
5218393
CYLINDER GP-DUAL TILT
Caterpillar
Caterpillar
5218392
CYLINDER GP-DUAL TILT
Caterpillar
Caterpillar