5343899 CYLINDER Caterpillar parts
Rating:
Alternative (cross code) number:
CA5343899
534-3899
5343899
CA5343899
534-3899
5343899
Information:
Illustration 1 g06008468
Schematic of the Boom Cylinder Retract Solenoid
This diagnostic code is associated with the Boom Cylinder Retract solenoid. The FMI "03" means that the Machine ECM detected that the voltage is above normal.The possible causes of this failure are listed below:
The solenoid energizer circuit is shorted to +battery.
The Machine ECM has failed. This condition is unlikely.When the diagnostic code occurs, a warning is displayed on the operator monitor and the hydraulic system is disabled.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO +BATTERY.
Turn the key start switch to the OFF position.
Disconnect the suspect solenoid from the machine harness.
Disconnect the machine harness connectors from the Cat® Grade Control ECM.
Measure the voltage at the circuits that are listed here:
Contact 1 (wire K760-PU(Purple)) of the machine harness connector for the solenoid to frame ground.
Contact 2 (wire K761-GN(Green)) of the machine harness connector for the solenoid to frame ground.
Contact 1 (wire K760-PU(Purple)) to contact 2 (wire K761-GN(Green)) of the machine harness connector for the solenoid.Expected Result:Each voltage measurement is approximately 0.0 0.5 DCV.Results:
OK - Each voltage measurement is approximately 0.0 0.5 DCV. The voltage is correct. Proceed to test step 2.
NOT OK - Each voltage measurement is greater than approximately 0.0 0.5 DCV. The voltage is not correct. The machine harness is shorted to +battery. Proceed to test step 2.Test Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the contacts.
Reconnect all machine harness connectors.
Turn the key start switch to the ON position.
Clear any active events that are displayed on the operator monitor.
Operate the machine.
Check if the diagnostic code is displayed on the operator monitor. The diagnostic information may also be viewed with the Cat® ET.Expected Result:The diagnostic code for the solenoid is NOT present on the operator monitor.Results:
YES - The diagnostic code is NOT present. The diagnostic code does not exist currently. The initial failure was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The diagnostic code has NOT been corrected. The machine ECM has failed. A failure of the ECM is unlikely. Exit this procedure and perform this procedure again.Repair: If the cause of the failure is not found, replace the Machine ECM. See Testing And Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Parts cylinder Caterpillar catalog:
5343569
CYLINDER
Caterpillar
Caterpillar
5343343
CYLINDER
Caterpillar
Caterpillar
5343157
CYLINDER
Caterpillar
Caterpillar
5343127
CYLINDER
Caterpillar
Caterpillar
5342724
CYLINDER
Caterpillar
Caterpillar
5342362
CYLINDER
Caterpillar
Caterpillar
5345669
CYLINDER
Caterpillar
Caterpillar
5345557
CYLINDER
Caterpillar
Caterpillar
5345483
CYLINDER
Caterpillar
Caterpillar
5345333
CYLINDER
Caterpillar
Caterpillar
5345167
CYLINDER
Caterpillar
Caterpillar
5343937
CYLINDER
Caterpillar
Caterpillar