Illustration 1 g01289178
Connections of "Secondary Steer Right" solenoid
This diagnostic code is associated with the "secondary steer right" solenoid. The FMI 05 means that the Transmission/Chassis ECM has determined that the current for the solenoid circuit is below normal.Conditions that could cause this diagnostic code to be activated are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 2.2 .2 ohms at 25 °C (77.0 °F).Test Step 1. CHECK THE SOLENOID
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire X755-WH(White)) to contact 2 (wire 925-YL(Yellow)).
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the CID 2176 FMI 05 diagnostic code. Expected Result:The CID 2176 FMI 05 diagnostic code is no longer active. A CID 2176 FMI 06 diagnostic code becomes active when the jumper wire is connected.Results:
YES - The CID 2176 FMI 05 diagnostic code is no longer active. A CID 2176 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The CID 2176 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE CIRCUIT FOR AN OPEN
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector J1 from the Transmission/Chassis ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector J1 for the Transmission/Chassis ECM, measure the resistance from contact J1-54 (wire 925-YL(Yellow)) to the contact J1-68 (wire X755-WH(White)). Expected Result:The resistance measurement is less than 5 ohms.Results:
OK - The measurement of the resistance is less than 5 ohms. The circuit is not open in the machine harness. Proceed to Test Step 3.
NOT OK - The resistance measurement is greater than 5000 ohms. The resistance measurement is not correct. There is an open or a bad connection in the machine harness.Repair: A
Parts damper Caterpillar catalog:
3298294
DAMPER AS
Caterpillar
Caterpillar
3193597
DAMPER AS.
Caterpillar
Caterpillar
3122750
DAMPER GP
Caterpillar
Caterpillar
3003852
DAMPER
Caterpillar
Caterpillar
2W5945
DAMPER G
Caterpillar
Caterpillar
2U2276
DAMPER
Caterpillar
Caterpillar
3762900
DAMPER-
Caterpillar
Caterpillar
3719382
DAMPER GP
Caterpillar
Caterpillar
3581174
DAMPER-SND
Caterpillar
Caterpillar
3412439
DAMPER AS-
Caterpillar
Caterpillar
3412438
DAMPER AS-
Caterpillar
Caterpillar
3412437
DAMPER AS-
Caterpillar
Caterpillar