Illustration 1 g01134079
Schematic of the Stick Drift Reduction SolenoidThis diagnostic code is associated with the Stick Drift Reduction Solenoid. The FMI 06 means that the ECM has determined that there is a short to ground in the circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1120 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 1120 FMI 06 changes to CID 1120 FMI 05 when the solenoid is disconnected.Results:
YES - CID 1120 FMI 06 changes to CID 1120 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Stop.
NO - CID 1120 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-67 (wire P945-OR) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-67 (wire P945-OR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1120 FMI 06. Expected Result:The CID 1120 FMI 06 is active. Results:
YES - The CID 1120 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 1120 FMI 06 is not active. The diagnostic code does not exist at this time.
Caterpillar parts catalog:
Parts damper Caterpillar catalog:
2884548
DAMPER & PULLEY GP
C13, C13 XQ350
C13, C13 XQ350
3965820
DAMPER AS
C27, C32
C27, C32
3057484
DAMPER GP
3516C
3516C
2831673
DAMPER GP
C175-16
C175-16
2819130
DAMPER
C32
C32
2817697
DAMPER
C32
C32
2715932
DAMPER-VIBRATION
C27, C32
C27, C32
2Y6457
DAMPER
140B, 3304, 3306, 966R, D4E
140B, 3304, 3306, 966R, D4E
2Y6219
DAMPER
120B, 3304B, 3306, 930R, 966R, D4E, D4E SR, D5B, D6D
120B, 3304B, 3306, 930R, 966R, D4E, D4E SR, D5B, D6D
4N8992
DAMPER
3406, 3408
3406, 3408
9L9282
DAMPER ASSEM.
1150, 1160, 3145, 3160
1150, 1160, 3145, 3160
2N1322
DAMPER
3160, 3208
3160, 3208