7J8080 DAMPER Caterpillar parts
183B, 235, 615, 615C, 621, 621B, 621E, 621F, 621G, 621R, 623B, 623E, 623F, 623G, 627B, 627E, 627F, 627G, 631C, 633C, 633D, 641B, 651E, 657E, 657G, 769, 773, 785, 789, 950B, 950B/950E, 966D, 966F, 966F...
Rating:
Alternative (cross code) number:
CA7J8080
7J-8080
7J8080
CA7J8080
7J-8080
7J8080
Weight: 0.04 pounds 0 kg.
EXCAVATOR, WHEEL TRACTOR,
Information:
Initial Start-Up
Preparing a generator for parallel operation requires special attention. Before you attempt to parallel units for the first time, check all the units for the following three conditions.
Same phase rotation
Same alternating current frequency
Same voltage adjustment
Check the phase rotation. Units that operate in parallel must have the same phase rotation. There are two methods that may be used in order to determine if the incoming unit and the unit that is on-line have the same phase rotation. These methods are listed below:
Using a phase rotation meter
Using a set of three light bulbsUse the procedure below to determine the proper phase rotation by using three light bulbs.
Illustration 1 g00695380
When servicing or repairing electric power generation equipment:Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. Remove all fuses.
Connect the light bulbs with rated voltage between the generator leads and the corresponding line phase. For example, connect terminal 1 to line 1 across the open circuit breaker.
Start the units that will be in operating in parallel. Bring the units up to speed. As the units approach the same speed, the lights will start to blink.
If the lights blink in sequence, one of the units is connected backward. In order to correct the problem, stop the units. Remove generator leads 1 and 3 at the circuit breaker. Exchange these generator leads. This reverses the direction of phase rotation. Terminal 2 should always be connected to line 2.
Both generators have the same phase rotation when the lights blink in unison. The first condition of "Initial Start-Up" has been met.
Adjust the frequency. The units that will be operating in parallel must operate at the same speed. Speed is proportional to the alternating current frequency.
Allow each electric set to run under load for about 30 minutes.
Adjust the governor control in order to give the rated frequency at full load.
Remove the load and check the high idle speed. The high idle speed should be approximately 2 to 5 percent above full load speed for governors that are equipped with droop. If these speeds can not be obtained, contact your Caterpillar dealer.
For the most consistent results, repeat 2.b and 2.c until the second condition of "Initial Start-Up" has been met.
Adjust the voltage.The potentiometers should be at the initial settings. Refer to Operation and Maintenance Manual, "Voltage Regulators". Note: Make sure that the speed droop is identical for all of the engines before adjustments are made to the generator.
Preset the unit for parallel operation by connecting the current transformer to S1 and S2 of the connector J2. Set potentiometer P1 for quadrature droop in the center position. Apply the rated load. The voltage should drop for 2% to 3%. Switch the positions of the two incoming secondary wires of the current transformer if the voltage increases.
The no-load voltages should be identical for all the generators that are operating in parallel. Connect the generators in parallel. Try to obtain a 0 kW power exchange by adjusting
Preparing a generator for parallel operation requires special attention. Before you attempt to parallel units for the first time, check all the units for the following three conditions.
Same phase rotation
Same alternating current frequency
Same voltage adjustment
Check the phase rotation. Units that operate in parallel must have the same phase rotation. There are two methods that may be used in order to determine if the incoming unit and the unit that is on-line have the same phase rotation. These methods are listed below:
Using a phase rotation meter
Using a set of three light bulbsUse the procedure below to determine the proper phase rotation by using three light bulbs.
Illustration 1 g00695380
When servicing or repairing electric power generation equipment:Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. Remove all fuses.
Connect the light bulbs with rated voltage between the generator leads and the corresponding line phase. For example, connect terminal 1 to line 1 across the open circuit breaker.
Start the units that will be in operating in parallel. Bring the units up to speed. As the units approach the same speed, the lights will start to blink.
If the lights blink in sequence, one of the units is connected backward. In order to correct the problem, stop the units. Remove generator leads 1 and 3 at the circuit breaker. Exchange these generator leads. This reverses the direction of phase rotation. Terminal 2 should always be connected to line 2.
Both generators have the same phase rotation when the lights blink in unison. The first condition of "Initial Start-Up" has been met.
Adjust the frequency. The units that will be operating in parallel must operate at the same speed. Speed is proportional to the alternating current frequency.
Allow each electric set to run under load for about 30 minutes.
Adjust the governor control in order to give the rated frequency at full load.
Remove the load and check the high idle speed. The high idle speed should be approximately 2 to 5 percent above full load speed for governors that are equipped with droop. If these speeds can not be obtained, contact your Caterpillar dealer.
For the most consistent results, repeat 2.b and 2.c until the second condition of "Initial Start-Up" has been met.
Adjust the voltage.The potentiometers should be at the initial settings. Refer to Operation and Maintenance Manual, "Voltage Regulators". Note: Make sure that the speed droop is identical for all of the engines before adjustments are made to the generator.
Preset the unit for parallel operation by connecting the current transformer to S1 and S2 of the connector J2. Set potentiometer P1 for quadrature droop in the center position. Apply the rated load. The voltage should drop for 2% to 3%. Switch the positions of the two incoming secondary wires of the current transformer if the voltage increases.
The no-load voltages should be identical for all the generators that are operating in parallel. Connect the generators in parallel. Try to obtain a 0 kW power exchange by adjusting
Cat SIS web machinery list:
Parts damper Caterpillar catalog:
4N2555
DAMPER
245, 3406, 3408, 3408B, 589, 621, 631E, 633D, 637D, 657E, 834B, 980C, 988B, D8L, D9N, PR-450
245, 3406, 3408, 3408B, 589, 621, 631E, 633D, 637D, 657E, 834B, 980C, 988B, D8L, D9N, PR-450
4N8249
DAMPER
245, 3304, 3306, 3406, 621, 980C
245, 3304, 3306, 3406, 621, 980C
2P5149
DAMPER AS
16G, 245, 3406, 3406B, 3408, 578, 621, 621B, 621E, 623E, 627E, 631E, 637D, 637E, 657E, 826C, 980C, 988B, 988F, G3406, SS-250
16G, 245, 3406, 3406B, 3408, 578, 621, 621B, 621E, 623E, 627E, 631E, 637D, 637E, 657E, 826C, 980C, 988B, 988F, G3406, SS-250
6N0537
DAMPER
12G, 14G, 235, 3304, 3306, 627B, 637D, 966C, 980B, D5, D6C, D7G
12G, 14G, 235, 3304, 3306, 627B, 637D, 966C, 980B, D5, D6C, D7G
1077495
DAMPER
824G II, 824H, 826H, 834G, 834H, 836H, 844, 854G, 966G II, 972G II, 980G II, 988H, 990 II, 992G, C-9, C27, C32, C9, C9.3, CX31-C9I, D10T, D11N, D11R, D8R, D8R II, D9R, R1600, R1600G, R1600H, R1700 II,...
824G II, 824H, 826H, 834G, 834H, 836H, 844, 854G, 966G II, 972G II, 980G II, 988H, 990 II, 992G, C-9, C27, C32, C9, C9.3, CX31-C9I, D10T, D11N, D11R, D8R, D8R II, D9R, R1600, R1600G, R1600H, R1700 II,...
6I9790
DAMPER-BOLT
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ, 797, 797B, 797F, 844, 844H, 844K, 854G, 854K, 990, 990 II, 990H, 990K, 992C, 992D, 9...
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ, 797, 797B, 797F, 844, 844H, 844K, 854G, 854K, 990, 990 II, 990H, 990K, 992C, 992D, 9...
8S4005
DAMPER
120G, 130G, 1673C, 215, 225, 3304, 3306, 518, 561C, 621R, 627, 920, 930, 950, 955K, 955L, 966C, D4D, D5, D5B, D6C, D7F, D7G
120G, 130G, 1673C, 215, 225, 3304, 3306, 518, 561C, 621R, 627, 920, 930, 950, 955K, 955L, 966C, D4D, D5, D5B, D6C, D7F, D7G
8S4000
DAMPER
120G, 12G, 130G, 14G, 1673C, 215, 225, 235, 3304, 3306, 3412, 518, 561C, 621R, 627, 627B, 637D, 920, 930, 950, 955K, 955L, 966C, 980B, D4D, D5, D5B, D6C, D7F, D7G
120G, 12G, 130G, 14G, 1673C, 215, 225, 235, 3304, 3306, 3412, 518, 561C, 621R, 627, 627B, 637D, 920, 930, 950, 955K, 955L, 966C, 980B, D4D, D5, D5B, D6C, D7F, D7G
7N9312
DAMPER ASSEM.
12G, 140G, 14G, 621R, 977K, D6C, D6D, D6G, D7F, D7G
12G, 140G, 14G, 621R, 977K, D6C, D6D, D6G, D7F, D7G
8S1503
DAMPER ASSEM.
14E, 627, 814, 966C, 977K, 980B, D6C, D7F
14E, 627, 814, 966C, 977K, 980B, D6C, D7F
6G6500
DAMPER AS
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
7D3013
DAMPER AS
772, 772B, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 776, 776C, 776D, 777, 777B, 777D, 777F, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B...
772, 772B, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 776, 776C, 776D, 777, 777B, 777D, 777F, 784B, 784C, 785, 785B, 785C, 785D, 789, 789B...
2P7834
DAMPER
225, 225D, 227, 229, 231D
225, 225D, 227, 229, 231D
2P3177
DAMPER ASSEM.
561C, D5
561C, D5
3639464
DAMPER
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
3639463
DAMPER
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
3639462
DAMPER
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
3639461
DAMPER
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
312E, 312E L, 316E L, 318E L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 349E, 349E L, 34...
1W8201
DAMPER
214, 224, AP-1200
214, 224, AP-1200
1W5298
DAMPER AS
235, 572G, D6H
235, 572G, D6H
7N6187
DAMPER
215, 910, 931B, 953
215, 910, 931B, 953
5C2563
DAMPER KIT
225, 245, 950
225, 245, 950
7N9312
DAMPER ASSEM.
12G, 140G, 14G, 621R, 977K, D6C, D6D, D6G, D7F, D7G
12G, 140G, 14G, 621R, 977K, D6C, D6D, D6G, D7F, D7G
8N9507
DAMPER
215
215