Information:
Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Caterpillar parts catalog:
Parts dash Caterpillar catalog:
1272415
DASH AS-MODULE
D10R, D11R, D9R
D10R, D11R, D9R
2256826
DASH AS
D10R
D10R
2051409
DASH GP
973C
973C
1866426
DASH AS
953C, 963C
953C, 963C
1435451
DASH AS
933C, 939C, D3C III, D4C III, D5C III
933C, 939C, D3C III, D4C III, D5C III
1249585
DASH AS
D6E, D6F SR, D6G SR
D6E, D6F SR, D6G SR
8Y9517
DASH AS
953B, 963B, 973
953B, 963B, 973
1044808
DASH AS
933, 939
933, 939
3323484
DASH AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3562832
DASH AS
587R
587R
3143001
DASH AS
D3K XL, D4K XL, D5K LGP, D6K LGP, PL61
D3K XL, D4K XL, D5K LGP, D6K LGP, PL61
2892021
DASH AS
D6K LGP
D6K LGP
3143000
DASH AS
D3K XL, D4K XL, D5K LGP, D6K, D6K LGP, PL61
D3K XL, D4K XL, D5K LGP, D6K, D6K LGP, PL61
2892020
DASH AS
D6K LGP
D6K LGP