4570905 DETECTOR GP-METHANE Caterpillar parts
Rating:
Alternative (cross code) number:
CA4570905
457-0905
4570905
CA4570905
457-0905
4570905
Weight: 0.16 pounds 0 kg.
Information:
Illustration 1 g02028493
"Hydraulic Pump #2 Outlet Pressure" sensor circuit schematic
This diagnostic code is associated with the "Hydraulic Pump #2 Outlet Pressure" sensor. An FMI 08 diagnostic code means the Machine ECM has determined the sensor output signal has an abnormal frequency, pulse width, or period. Possible causes for this diagnostic code are listed below:
Failed sensor.
Short circuit to the sensor output signal wire.
Failed Machine ECM (unlikely).Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes now, but clear those codes after the original diagnostic code has been corrected. Note: Poor connections are often the cause of a problem in electrical circuits. Before performing this procedure, inspect all of the harness connectors involved in the circuit. Verify that all of the connections in the circuit are clean, secure, and in good condition. If a problem is found with any of the connections: correct the problem and verify that diagnostic code CID 2266 FMI 08 is still active, before performing the following procedures. Test Step 1. CHECK THE SENSOR, THE ECM, AND THE MACHINE HARNESS.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector from the "Hydraulic Pump #2 Outlet Pressure" sensor.
In the harness connector for the sensor, place a jumper wire between the contact for terminal C (wire T967-YL(Yellow)) and the contact for terminal B (wire A209-BK(Black)) in the sensor connector.
Turn the key start switch and the disconnect switch to the ON position.
Observe the status of the diagnostic code. Expected Result:The 2266 FMI 08 diagnostic code remains active. Results:
YES - The CID 2266 FMI 08 diagnostic code remains active. The sensor is not the cause of the problem. Go to Test Step 2.
NO - The CID 2266 FMI 08 diagnostic code is no longer active. The diagnostic code has been replaced by an active CID 2266 with a different FMI code. The sensor has failed. Repair: Replace the sensor. Go to Test Step 3.Test Step 2. CHECK THE MACHINE HARNESS FOR A SHORT CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
The sensor remains disconnected from the harness connector.
Remove the jumper wire from the connector.
Disconnect both the J1 and J2 harness connector from the machine ECM.
At the ECM J1 harness connector , measure the resistance between contact J1-35 (wire T967-YL(Yellow)) and frame ground.
Again at the ECM J1 harness connector , measure the resistance between contact J1-35 (wire T967-YL(Yellow)) and all of the other contacts that are used in both the J1 and J1 ECM harness connectors. Expected Result:All resistance readings are greater than 5000 ohms. Results:
YES - All resistance readings are greater than 5000 ohms. Go to Test Step 3.
NO - All resistance readings are not greater than 5000 ohms. There is a short circuit in the machine harness. Repair: Repair or replace the harness.Go to Test Step 3.Test Step 3. CHECK THE DIAGNOSTIC CODE STATUS.
Reconnect all disconnected machine harness connectors. Make sure that all the connectors are fully seated. Observe that the clips
Caterpillar parts catalog:
Parts detector Caterpillar catalog:
4565077
DETECTOR GP-METHANE
Caterpillar
Caterpillar
2309874
DETECTOR
CB-214D
CB-214D
1796207
DETECTOR
CB-214D
CB-214D
1432920
DETECTOR-FLAME
10-20B, 8-16B, BG-225B
10-20B, 8-16B, BG-225B
0351335
DETECTOR
Caterpillar
Caterpillar
0351334
DETECTOR
Caterpillar
Caterpillar
5147298
DETECTOR
Caterpillar
Caterpillar
4969766
DETECTOR GP
Caterpillar
Caterpillar
4478639
DETECTOR GP-OIL MIST
Caterpillar
Caterpillar
4681945
DETECTOR GP-METHANE
Caterpillar
Caterpillar