TYPE="LEVEL" DEPTH="2" @@@-->KG30 Governor Control Unit
KG30 Governor Control Unit
(1) Diode. (2) Max fuel 5V potentiometer. (3) Stop 1.5V potentiometer. (4) Min speed potentiometer. (5) Max speed potentiometer. (6) Gain potentiometer. (7) Stability potentiometer. (8) Derivative potentiometer. (9) Gas-Gain potentiometer. (10) Gas-Diesel switch. (11) Start fuel limit potentiometer. (12) Start fuel limit slide switch. (13) Green LED light. (14) OV (-). (15) TP6 (+). (16) Droop potentiometer. (17) Droop-Isoch switch. (18) Speed variance potentiometer. (19) Fast response potentiometer. (20) Damping potentiometer.
KG30 Governor Control Unit
Earlier (Green Control Board)
KG30 Governor Control Unit
Later (White Control Board)The KG30 Governor Control Unit provides precision engine speed control. The system measures engine speed constantly, and makes necessary corrections to the engine fuel setting through an actuator connected to the fuel system.The engine speed is sensed by a magnetic pickup. As the teeth of the flywheel ring gear cuts through the magnetic lines of force around the pickup, an AC voltage is generated. The frequency of this voltage is directly proportional to engine speed. An electric circuit inside the governor control unit processes this AC voltage. In response it sends a signal from the control to the actuator to maintain the set speed.The actuator is connected to the fuel system by linkage. It changes the electrical input from the governor control unit to mechanical output that changes the engine fuel setting. For example, if the engine speed was greater than the speed setting, the governor control unit will decrease fuel to the engine.The Rated and Low Idle engine speeds are set with internal speed setting potentiometers. The engine speed is adjusted with a remote 10 turn potentiometer, or as a function of voltage, current or air pressure with an optional speed set point unit.The Gain, Stability and Derivative Potentiometers control the speed stability and the response time of the engine to a change in load. Gain affects the amount of speed deviation and recovery time. Stability affects rate of recovery, overshoot and response time for the Gain setting used. Derivative affects rate of speed deviation and thus response time to some degree, but is mainly for additional fine-tuning of engine stability.The Speed Droop Potentiometer controls the amount of speed droop. It can be set between 0 and 10%. Droop is only necessary when paralleling with a utility bus or a generator with a hydramechanical governor. When operating a generator set in droop where the LMG 03 Loadshare Unit is used, the KG30 Control Unit is put in Isochronous mode and the droop is set in the separate LMG 03 Loadshare Unit.The Start Fuel Limit Potentiometer is used to control the amount of fuel to the engine during startup. It can be adjusted to make the engine start easier, to decrease startup smoke and to limit startup overshoot. The fuel limiting function is turned off automatically when the speed control takes over.The speed failsafe circuit will drive the actuator to shutoff if the magnetic pickup signal becomes less than 150 Hz. Magnetic pickup failure or slow engine
KG30 Governor Control Unit
(1) Diode. (2) Max fuel 5V potentiometer. (3) Stop 1.5V potentiometer. (4) Min speed potentiometer. (5) Max speed potentiometer. (6) Gain potentiometer. (7) Stability potentiometer. (8) Derivative potentiometer. (9) Gas-Gain potentiometer. (10) Gas-Diesel switch. (11) Start fuel limit potentiometer. (12) Start fuel limit slide switch. (13) Green LED light. (14) OV (-). (15) TP6 (+). (16) Droop potentiometer. (17) Droop-Isoch switch. (18) Speed variance potentiometer. (19) Fast response potentiometer. (20) Damping potentiometer.
KG30 Governor Control Unit
Earlier (Green Control Board)
KG30 Governor Control Unit
Later (White Control Board)The KG30 Governor Control Unit provides precision engine speed control. The system measures engine speed constantly, and makes necessary corrections to the engine fuel setting through an actuator connected to the fuel system.The engine speed is sensed by a magnetic pickup. As the teeth of the flywheel ring gear cuts through the magnetic lines of force around the pickup, an AC voltage is generated. The frequency of this voltage is directly proportional to engine speed. An electric circuit inside the governor control unit processes this AC voltage. In response it sends a signal from the control to the actuator to maintain the set speed.The actuator is connected to the fuel system by linkage. It changes the electrical input from the governor control unit to mechanical output that changes the engine fuel setting. For example, if the engine speed was greater than the speed setting, the governor control unit will decrease fuel to the engine.The Rated and Low Idle engine speeds are set with internal speed setting potentiometers. The engine speed is adjusted with a remote 10 turn potentiometer, or as a function of voltage, current or air pressure with an optional speed set point unit.The Gain, Stability and Derivative Potentiometers control the speed stability and the response time of the engine to a change in load. Gain affects the amount of speed deviation and recovery time. Stability affects rate of recovery, overshoot and response time for the Gain setting used. Derivative affects rate of speed deviation and thus response time to some degree, but is mainly for additional fine-tuning of engine stability.The Speed Droop Potentiometer controls the amount of speed droop. It can be set between 0 and 10%. Droop is only necessary when paralleling with a utility bus or a generator with a hydramechanical governor. When operating a generator set in droop where the LMG 03 Loadshare Unit is used, the KG30 Control Unit is put in Isochronous mode and the droop is set in the separate LMG 03 Loadshare Unit.The Start Fuel Limit Potentiometer is used to control the amount of fuel to the engine during startup. It can be adjusted to make the engine start easier, to decrease startup smoke and to limit startup overshoot. The fuel limiting function is turned off automatically when the speed control takes over.The speed failsafe circuit will drive the actuator to shutoff if the magnetic pickup signal becomes less than 150 Hz. Magnetic pickup failure or slow engine
Caterpillar SIS machinery equipment:
Caterpillar SIS
D10R Track-Type Tractor 3KR00001-UP (MACHINE) POWERED BY 3412 Engine »
127-2945
DETENT GP
D6M TRACK-TYPE TRACTOR XL, LGP 3WN00001-UP (MACHINE) POWERED BY 3116 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor XL 4MN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D5M & D5M LGP Track-Type Tractor 3CR00001-UP (MACHINE) POWERED BY 3116 Engine »
127-2945
DETENT GP
D7R Track-Type Tractor LGP 9HM00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D11R Track-Type Tractor Power Shift 8ZR00001-UP (MACHINE) POWERED BY 3508 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor 2YN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor 8LN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor XR Power Shift 6JN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor Power Shift 6MR00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6M Track-Type Tractor XL Power Shift 6LR00001-UP (MACHINE) POWERED BY 3116 Engine »
127-2945
DETENT GP
D7R Track-Type Tractor 2HR00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor 2HM00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor 4JR00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor XR 8XN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D6R Track-Type Tractor LGP 4HN00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D11R Track-Type Tractor 9TR00001-UP (MACHINE) POWERED BY 3508 Engine »
127-2945
DETENT GP
D11R Carrydozer Track-Type Tractor 9XR00001-UP (MACHINE) POWERED BY 3508B Engine »
127-2945
DETENT GP
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 3508B Engine »
127-2945
DETENT GP
572R Pipelayer 2HZ00001-UP (MACHINE) POWERED BY 3306 Engine »
127-2945
DETENT GP
D7R Track-Type Tractor AFG00001-UP (MACHINE) POWERED BY 3176C Engine »
127-2945
DETENT GP
D7R Track-Type Tractor ACS00001-UP (MACHINE) POWERED BY 3176C Engine »
127-2945
DETENT GP
D11R Carrydozer Track-Type Tractor AAF00001-UP (MACHINE) POWERED BY 3508B Engine »
127-2945
DETENT GP
D6R Series IITRACK-TYPE TRACTOR FTC AEM00001-UP (MACHINE) POWERED BY C-9 Engine »
127-2945
DETENT GP
D10R TRACK-TYPE TRACTOR AKT00001-UP (MACHINE) POWERED BY 3412E Engine »
127-2945
DETENT GP
D6N XL, FTC, LGP TRACK-TYPE TRACTOR ALH00001-UP (MACHINE) POWERED BY 3126B Engine »
127-2945
DETENT GP
D5N XL, LGP TRACK-TYPE TRACTOR AGG00001-UP (MACHINE) POWERED BY 3126B Engine »
127-2945
DETENT GP
D6R SERIES II TRACK-TYPE TRACTOR BLE00001-UP (MACHINE) POWERED BY C-9 Engine »
127-2945
DETENT GP
D6R Series SERIES IIFTC,LGP TRACK-TYPE TRACTOR ACJ00001-UP (MACHINE) POWERED BY C-9 Engine »
127-2945
DETENT GP
D6R Series IIFTC, XL TRACK-TYPE TRACTORS BRJ00001-UP (MACHINE) POWERED BY C-9 Engine »
127-2945
DETENT GP
561N Pipelayer CPH00001-UP (MACHINE) POWERED BY 3126B Engine »
127-2945
DETENT GP
D6N XL, FTC TRACK-TYPE TRACTOR CBJ00001-UP (MACHINE) POWERED BY 3126B Engine »
127-2945
DETENT GP
572R Series II Pipelayer DSC00001-UP (MACHINE) POWERED BY 3176C Engine »
127-2945
DETENT GP
Cat SIS web machinery list:
Parts detent Caterpillar catalog:
2354495
DETENT GP
572R II, 587T, D10T, D10T2, D11T, PL87
572R II, 587T, D10T, D10T2, D11T, PL87
1997834
DETENT AS
844H, 854G, 854K, D5N, D6N, D6R, D6R II, D6R III, D6R STD, D6T, D7R II, D7R XR, D8R II
844H, 854G, 854K, D5N, D6N, D6R, D6R II, D6R III, D6R STD, D6T, D7R II, D7R XR, D8R II
4T1855
DETENT
926, 936, 936F, D6H, D6H II, D6H XL, D6H XR, D6R, D7H, D7R, D9R, G936, IT28, IT28B
926, 936, 936F, D6H, D6H II, D6H XL, D6H XR, D6R, D7H, D7R, D9R, G936, IT28, IT28B
1892305
DETENT GP-CONTROL
621G, 623G, 627G, 631E, 631G, 637E, 637G, 657E, D10R, D11R, D8T, D9T
621G, 623G, 627G, 631E, 631G, 637E, 637G, 657E, D10R, D11R, D8T, D9T
1436406
DETENT
D11R
D11R
1303535
DETENT GP-CONTROL VALVE
120H, 120H ES, 12H, 12H ES, 135H, 140H, 140H ES, 143H, 14H, 14H NA, 160H, 160H ES, 163H, 163H NA, 16H, 16H NA
120H, 120H ES, 12H, 12H ES, 135H, 140H, 140H ES, 143H, 14H, 14H NA, 160H, 160H ES, 163H, 163H NA, 16H, 16H NA
1524216
DETENT GP-CONTROL VALVE
35, 45, 55, 65E, 75E, 85E, 95E
35, 45, 55, 65E, 75E, 85E, 95E
1054200
DETENT GP-CONTROL VALVE
45, 55, 65C, 70C, 75C, 75D, 85C, 85D
45, 55, 65C, 70C, 75C, 75D, 85C, 85D
1084916
DETENT GP-CONTROL VALVE
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 24H
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 24H
2354495
DETENT GP
572R II, 587T, D10T, D10T2, D11T, PL87
572R II, 587T, D10T, D10T2, D11T, PL87