3679408 DIFFERENTIAL & BEVEL GEAR GP Caterpillar parts
993K
Rating:
Alternative (cross code) number:
CA3679408
367-9408
3679408
CA3679408
367-9408
3679408
Weight: 2989 pounds 1355 kg.
WHEEL LOADER,
Compatible equipment models: 3679408:
Information:
Standard Motor
Illustration 1 g03796062
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Engine (12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (17) Tank
Illustration 2 g03789601
(12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Outlet (20) InletThe speed of the fan is controlled by demand fan solenoid valve (16) . The demand fan solenoid valve is controlled by the machine ECM. The speed of the fan motor depends on the amount of flow that is allowed through valve (16) for the fan. The control of the fan speed is based on the value of the following conditions:
Inlet manifold temperature
Transmission oil temperature
Hydraulic oil temperature
Engine coolant temperature
Ambient temperature (if the air conditioning is on)The machine ECM may require more air flow for cooling. If so, the machine ECM will decrease the amount of electric current sent to demand fan solenoid valve (16) . This decrease will close the demand fan solenoid valve. When the demand fan solenoid valve closes more, the pressure of pilot oil acting on flow control valve (23) for the fan increases. This action restricts the flow of oil through the flow control valve for the fan. Restricted oil flow through the flow control valve causes oil from the braking and hydraulic fan pump (10) to flow through fan motor (12) . The fan motor will turn faster. The speed of the fan depends on the following inputs:
The amount of current that is sent to the demand fan solenoid valve
The amount of pump flow that is availableThe machine ECM may not require more air flow for cooling. If so, the machine ECM will increase the amount of electric current to the demand fan solenoid valve. This increase will shift the demand fan solenoid valve more open. This action will increase the flow of oil through the flow control valve for the fan. Increased results in less oil flowing to the fan motor. The fan motor will turn more slowly. The speed of the fan depends on the amount of current that is sent to the demand fan solenoid valve.Makeup valve (15) prevents cavitation of the fan motor during deceleration.From the fan motor, hydraulic oil flows directly back to the hydraulic oil tank.Reversing Motor
Illustration 3 g03789688
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Motor and Pump Stack (13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (17) Tank (21) Reversing Fan Motor
Illustration 4 g03789623
(13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Inlet (20) Outlet (21) Fan MotorThe machine can be equipped with a reversing fan. The cooling capacity of the
Illustration 1 g03796062
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Engine (12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (17) Tank
Illustration 2 g03789601
(12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Outlet (20) InletThe speed of the fan is controlled by demand fan solenoid valve (16) . The demand fan solenoid valve is controlled by the machine ECM. The speed of the fan motor depends on the amount of flow that is allowed through valve (16) for the fan. The control of the fan speed is based on the value of the following conditions:
Inlet manifold temperature
Transmission oil temperature
Hydraulic oil temperature
Engine coolant temperature
Ambient temperature (if the air conditioning is on)The machine ECM may require more air flow for cooling. If so, the machine ECM will decrease the amount of electric current sent to demand fan solenoid valve (16) . This decrease will close the demand fan solenoid valve. When the demand fan solenoid valve closes more, the pressure of pilot oil acting on flow control valve (23) for the fan increases. This action restricts the flow of oil through the flow control valve for the fan. Restricted oil flow through the flow control valve causes oil from the braking and hydraulic fan pump (10) to flow through fan motor (12) . The fan motor will turn faster. The speed of the fan depends on the following inputs:
The amount of current that is sent to the demand fan solenoid valve
The amount of pump flow that is availableThe machine ECM may not require more air flow for cooling. If so, the machine ECM will increase the amount of electric current to the demand fan solenoid valve. This increase will shift the demand fan solenoid valve more open. This action will increase the flow of oil through the flow control valve for the fan. Increased results in less oil flowing to the fan motor. The fan motor will turn more slowly. The speed of the fan depends on the amount of current that is sent to the demand fan solenoid valve.Makeup valve (15) prevents cavitation of the fan motor during deceleration.From the fan motor, hydraulic oil flows directly back to the hydraulic oil tank.Reversing Motor
Illustration 3 g03789688
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Motor and Pump Stack (13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (17) Tank (21) Reversing Fan Motor
Illustration 4 g03789623
(13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Inlet (20) Outlet (21) Fan MotorThe machine can be equipped with a reversing fan. The cooling capacity of the
Caterpillar SIS machinery equipment:
Caterpillar SIS
993K Wheel Loader Z9K00001-UP (MACHINE) POWERED BY C32 Engine »
367-9408
DIFFERENTIAL & BEVEL GEAR GP
993K Wheel Loader Z4Z00001-UP (MACHINE) POWERED BY C32 Engine »
367-9408
DIFFERENTIAL & BEVEL GEAR GP
993K Wheel Loader Z4D00001-UP (MACHINE) POWERED BY C32 Engine »
367-9408
DIFFERENTIAL & BEVEL GEAR GP
Caterpillar parts catalog:
Parts differential Caterpillar catalog:
1089389
DIFFERENTIAL AR
IT14F
IT14F
7D8840
DIFFERENTIAL GP
768B, 769
768B, 769
1256046
DIFFERENTIAL & BEVEL GEAR GP
789B, 789C
789B, 789C
2404663
DIFFERENTIAL & BEVEL GEAR GP
824H, 824K
824H, 824K
6W1492
DIFFERENTIAL & BEVEL GEAR GP
815B, 816B
815B, 816B
1S1874
DIFFERENTIAL AND GEAR GROUP
824, 824B, 988
824, 824B, 988
1598532
DIFFERENTIAL GP
D350E II, D400E II
D350E II, D400E II
2826915
DIFFERENTIAL & BEVEL GEAR GP
725, 730