1S7442 DIODE Caterpillar parts
16, 651
Rating:
Alternative (cross code) number:
CA1S7442
1S-7442
1S7442
CA1S7442
1S-7442
1S7442
Weight: 0.31 pounds 0 kg.
MOTOR GRADER, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$152.42
13 Oct 2023
0.35[0.16] Pounds
Amazon.com
WVE by NTK 1S7442 Windshield Wiper Switch, 1 Pack
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
WVE by NTK Wiper switch controls the activation and speed of the wiper motor and in some models also controls the washer || When not replaced, wipers may run continually, not function or function at only one speed || Designed to meet or exceed OE specifications in form, fit and function || Global coverage for import and/or domestic applications
Information:
Illustration 1 g01079452
Schematic of the Solenoid valve (1) for the counterbalance valveThis diagnostic code is associated with the solenoid valve 1 for the counterbalance valve. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of this diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2235 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active the state of the hydraulic control mode should not change.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-2 (wire Y925-YL) to all contacts that are used in the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (Y925-YL) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 2235 FMI 03 is active.Expected Result:The CID 2235 FMI 03 is active.Results:
YES - The CID 2235 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 2235 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Cat SIS web machinery list:
Parts diode Caterpillar catalog:
9M0819
DIODE
16, 651
16, 651
6D5320
DIODE
14E, 16
14E, 16
6D5319
DIODE
14E, 16
14E, 16
6D5318
DIODE
14E, 16
14E, 16
6D9713
DIODE ASSEM.
12F, 140, 14E, 16
12F, 140, 14E, 16
8U8088
DIODE GP
206B, 212B
206B, 212B
8U8089
DIODE AS
206B, 212B
206B, 212B
8U8045
DIODE
206B, 212B
206B, 212B
8U8044
DIODE GP
206B, 212B
206B, 212B
2Y3331
DIODE (Negative)
120B, 225, 930, D6C, D6D
120B, 225, 930, D6C, D6D
8U3562
DIODE GP
213B, 214B, 224B
213B, 214B, 224B
1185597
DIODE AS
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 521, 522, 532, 541, 541 2, 551, 552, 552 2, 910K, 914G, 914K, 924G, 924GZ, 924H, 924HZ, 924K, 928G, 928H, 928HZ, 930G, 930K, 938F, 93...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 521, 522, 532, 541, 541 2, 551, 552, 552 2, 910K, 914G, 914K, 924G, 924GZ, 924H, 924HZ, 924K, 928G, 928H, 928HZ, 930G, 930K, 938F, 93...
2Y2018
DIODE
120B, D6C
120B, D6C
3Y4700
DIODE (+)
941
941
3Y4701
DIODE (-)
941
941
4Y8349
DIODE ASSEM.
918F, 924F, 938F, 950F, 966F, 980F, D7H
918F, 924F, 938F, 950F, 966F, 980F, D7H
9M0819
DIODE
16, 651
16, 651