Illustration 1 g01302723
Schematic of the Clutch Solenoid "6 - First"This diagnostic code is associated with the Clutch Solenoid "6 - First". The FMI 06 means that the ECM has determined that the current of the solenoid is above normal. The possible causes of this diagnostic code are listed:
The solenoid energizer circuit of the modulating valve is shorted to ground.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1406 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 1406 FMI 06 changes to CID 1406 FMI 05 when the solenoid is disconnected.Results:
YES - CID 1406 FMI 06 changes to CID 1406 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - CID 1406 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-2 (wire 901-WH) to all contacts that are used in the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-2 (wire 901-WH) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1406 FMI 06.Expected Result:The CID 1406 FMI 06 is active.Results:
YES - The CID 1406 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". STOP
NO - The CID 1406 FMI 06 is
Caterpillar parts catalog:
Parts door Caterpillar catalog:
4812503
DOOR GP-CAB
Caterpillar
Caterpillar
4536966
DOOR GP-ACCESS
Caterpillar
Caterpillar
4536963
DOOR GP-ACCESS
Caterpillar
Caterpillar
4422059
DOOR AS-CAB
Caterpillar
Caterpillar
4422054
DOOR GP-CAB
Caterpillar
Caterpillar
4200179
DOOR
Caterpillar
Caterpillar
4897993
DOOR AS
Caterpillar
Caterpillar
4897983
DOOR GP-ACCESS
Caterpillar
Caterpillar
4878605
DOOR GP-CAB
Caterpillar
Caterpillar
4849477
DOOR AS
Caterpillar
Caterpillar
4849372
DOOR GP-CAB
Caterpillar
Caterpillar
4849365
DOOR AS-ACCESS
Caterpillar
Caterpillar