8P3400 DOOR ASSEM. Caterpillar parts
D7G
Rating:
Alternative (cross code) number:
CA8P3400
8P-3400
8P3400
CA8P3400
8P-3400
8P3400
Weight: 33 pounds 14 kg.
TRACK-TYPE TRACTOR,
Compatible equipment models: 8P3400:
Information:
Illustration 1 g01156241
Schematic for the Lift Linkage Raise SolenoidThis diagnostic code is associated with the lift linkage raise solenoid. The FMI 06 means that the ECM has determined that the current for the solenoid is above normal. There may be a short to ground in the solenoid circuit.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. System Response:The machine response is listed:
The lift linkage solenoid will turn OFF.
The blade raise function will be disabled until the diagnostic code is corrected and the levers are centered.Note: The following test procedure may create other diagnostic codes. Ignore the created diagnostic codes. Clear these diagnostic codes when the original diagnostic code is corrected.Note: Ensure that the diagnostic code is active and that the diagnostic code indicator is active.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness.Expected Result:CID 0354 FMI 06 changes to CID 0354 FMI 05 when the solenoid is disconnected.Results:
YES - The active diagnostic code CID 0354 FMI 06 changes to CID 0354 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Stop.
NO - The active diagnostic code CID 0354 FMI 06 does not change. The code is still active. Proceed to Test Step 2.Test Step 2. CHECK THE SOLENOID ENERGIZE CIRCUIT FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness ECM connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from the signal contact J1-10 (wire H713-PK) to all ECM ground and frame ground contacts on connectors J1 and J2. The ground contacts on connector J1 are J1-2, J1-5, J1-7, J1-15 and J1-16. The ground contact on connector J2 is J2-3.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-10 (wire H713-PK) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE
Inspect the contacts of the harness connectors that are used in the solenoid circuit. Ensure that the contacts are secure. Clean all of the contacts in the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0354 FMI 06.Expected Result:The CID 0354 FMI 06 diagnostic code is active.Results:
YES - The CID 0354 FMI 06 code
Caterpillar parts catalog:
Parts door Caterpillar catalog:
3P6246
DOOR
D7G
D7G
6P6045
DOOR ASSEM.
D7G, D8K
D7G, D8K
3Y6580
DOOR
D7G
D7G
3Y4146
DOOR
D7G
D7G
3Y5391
DOOR
D7G
D7G
5S0478
DOOR ASSEM.
D8H, D8K
D8H, D8K
3P6246
DOOR
D7G
D7G
6P0532
DOOR
D9H
D9H
6P6045
DOOR ASSEM.
D7G, D8K
D7G, D8K
8P5763
DOOR
193
193