9V8947 DOOR AS-L.H. Caterpillar parts
950B, 950B/950E
Rating:
Alternative (cross code) number:
CA9V8947
9V-8947
9V8947
CA9V8947
9V-8947
9V8947
Weight: 52 pounds 23 kg.
WHEEL LOADER,
This part in 2 request:
Show.
This information for suppliers only!
2016-08-29
2016-08-16
Information:
Disable Regeneration - Press in the bottom switch for 2 seconds to disable regeneration.Note: If equipped with a rocker style switch, the MIDDLE position of the regeneration switch is the default position for automatic regeneration.Note: If the engine start switch key is cycled or the "Force Regeneration" switch is pressed for longer than 2 seconds the system will no longer be disabled. When the "Force Regeneration" switch is pressed and "Time to Regen" is less than 8 hours, regeneration will begin if the machine is at low idle and is parked.Note: If the engine start switch key is cycled while the regeneration system is disabled via the "Disable Regeneration" switch, press and hold the "Disable Regeneration" switch for 2 seconds to reinitiate.Modes of Regeneration
Automatic: The Electronic Control Module (ECM) uses multiple inputs from the engine and the machine to determine the best time to perform an automatic regeneration. Automatic regenerations can take place throughout the operating cycle of the engine. The regeneration active indicator will be illuminated when a regeneration is being performed. Interruptions of the regeneration are acceptable. If a regeneration is in progress and needs to be stopped, it is permissible to press the "Disable Regeneration" switch.Note: Automatic adjustments of engine speed may be noticed during regenerations. If a regeneration is taking place and the engine is taken to low idle, the engine speed may remain elevated to maintain the regeneration.Note: If the machine returns to work while an automatic regeneration is active, the regeneration may be stopped. The ECM will continue to monitor inputs to determine the best time to restart the regeneration.Manual: A manual regeneration is initiated by pressing the "Force Regeneration" switch. A manual regeneration will only be allowed if the "Time to Regen" is less than 8 hours. If the "Force Regeneration" switch is pressed before "Time to Regen" is less than 8 hours, then “Regen not Required” will be displayed. The machine must be stationary, the parking brake must be applied, and the engine must be at low idle to perform a manual regeneration.Disabled: When the regeneration system is in disabled mode, automatic regenerations will not be performed. The DPF indicator will illuminate if a manual regeneration is required. The "Time to Regen" displayed on the performance screen will indicate the time until the next regeneration will be required. However, the DPF indicator may illuminate with time remaining on the display. When the DPF indicator illuminates, the operator must perform a manual regeneration.Regeneration Triggers
A regeneration may be required for the following reasons:Soot: The DPF will collect soot produced by the engine. An automatic regeneration will become active to reduce soot level.Start-Up Regeneration: A start-up regeneration is initiated by the ECM after a cold engine start. This regeneration is performed to heat the system to a required temperature for Diesel Exhaust Fluid (DEF) dosing to begin.SCR Maintenance: A regeneration is performed to maintain the SCR system.ARD Maintenance: A regeneration is performed to maintain the ARD system.Regeneration System Warning Indicators
Illustration 1 g02117258The DPF Indicator
Automatic: The Electronic Control Module (ECM) uses multiple inputs from the engine and the machine to determine the best time to perform an automatic regeneration. Automatic regenerations can take place throughout the operating cycle of the engine. The regeneration active indicator will be illuminated when a regeneration is being performed. Interruptions of the regeneration are acceptable. If a regeneration is in progress and needs to be stopped, it is permissible to press the "Disable Regeneration" switch.Note: Automatic adjustments of engine speed may be noticed during regenerations. If a regeneration is taking place and the engine is taken to low idle, the engine speed may remain elevated to maintain the regeneration.Note: If the machine returns to work while an automatic regeneration is active, the regeneration may be stopped. The ECM will continue to monitor inputs to determine the best time to restart the regeneration.Manual: A manual regeneration is initiated by pressing the "Force Regeneration" switch. A manual regeneration will only be allowed if the "Time to Regen" is less than 8 hours. If the "Force Regeneration" switch is pressed before "Time to Regen" is less than 8 hours, then “Regen not Required” will be displayed. The machine must be stationary, the parking brake must be applied, and the engine must be at low idle to perform a manual regeneration.Disabled: When the regeneration system is in disabled mode, automatic regenerations will not be performed. The DPF indicator will illuminate if a manual regeneration is required. The "Time to Regen" displayed on the performance screen will indicate the time until the next regeneration will be required. However, the DPF indicator may illuminate with time remaining on the display. When the DPF indicator illuminates, the operator must perform a manual regeneration.Regeneration Triggers
A regeneration may be required for the following reasons:Soot: The DPF will collect soot produced by the engine. An automatic regeneration will become active to reduce soot level.Start-Up Regeneration: A start-up regeneration is initiated by the ECM after a cold engine start. This regeneration is performed to heat the system to a required temperature for Diesel Exhaust Fluid (DEF) dosing to begin.SCR Maintenance: A regeneration is performed to maintain the SCR system.ARD Maintenance: A regeneration is performed to maintain the ARD system.Regeneration System Warning Indicators
Illustration 1 g02117258The DPF Indicator
Caterpillar parts catalog:
Parts door Caterpillar catalog:
8V0117
DOOR AS
950B
950B
8V0118
DOOR AS
950B
950B
7V9671
DOOR AS
950B
950B
8V0149
DOOR AS
950B
950B
9V1400
DOOR AS-RH
950B
950B
9V1399
DOOR AS-LH
950B
950B
9V1401
DOOR AS-RH
950B
950B
9V1398
DOOR AS-LH
950B
950B
9V8981
DOOR AS-RH
950B
950B
9V8984
DOOR AS-LH
950B
950B
9V8972
DOOR AS-RH
950B
950B
9V8973
DOOR AS-LH
950B
950B
9V8948
DOOR AS-R.H.
950B, 950B/950E
950B, 950B/950E
9V8951
DOOR AS-L.H.
950B, 950B/950E
950B, 950B/950E
9V8950
DOOR AS-R.H.
950B, 950B/950E
950B, 950B/950E
6C0447
DOOR AS
966D
966D
6C0448
DOOR AS
966D
966D
8V2531
DOOR AS-LH
814B, 815B, 816B, 966D
814B, 815B, 816B, 966D
9V0804
DOOR AS-LH
814B, 815B, 966D
814B, 815B, 966D
9V0801
DOOR AS-RH
814B, 815B, 966D
814B, 815B, 966D
8V0149
DOOR AS
950B
950B
7V9671
DOOR AS
950B
950B
8V0118
DOOR AS
950B
950B
8V0117
DOOR AS
950B
950B