1A3284 DOWEL (1.375" LONG) Caterpillar parts
16, 1693, 215, 215B, 215C, 583K, 594, 594H, 631C, 657B, 769, 955K, 955L, 977K, 983, D320A, D343, D5H, D5H XL, D5HTSK II, D8H, D8K, D9G, D9H, G343
Rating:
Alternative (cross code) number:
CA1A3284
1A-3284
1A3284
CA1A3284
1A-3284
1A3284
Weight: 0.010 pounds 0 kg.
Information:
OVERALL LENGTH
35
mm
OUTSIDE PIN DIAMETER
12.543
mm
END TYPE A
CHAMFER
END TYPE B
CHAMFER
FLAT/VENTED
N
INSIDE DIAMETER
0
EXCAVATOR, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 1A3284:
Information:
Description
Illustration 1 g01277041
(1) AC Interface (ACI) board The AC Interface (ACI) board (1) monitors the voltages on the following nodes: input, filter and output. Contactor K1 and contactor K2 are controlled via two relays that are located on the board (1).The MMS performs the following functions:
Controlling the K1 contactor
Controlling the K2 contactor
Monitoring the input current
Monitoring the output currentRemoval Procedure
Refer to Systems Operation, Testing and Adjusting, UENR3954, "Internal Component Preremoval Steps (Flywheel Cabinet)" in order to shut down the system and gain access to internal components.
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in a static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Illustration 2 g01277042
AC Interface (ACI) board
Disconnect all connectors. Verify each label for each connector for subsequent installation. Refer to Illustration 2.
Disconnect the white plastic standoffs that connect the board (1) to the left panel. Note: The board (1) must be removed from the standoffs without bending the board.
Compress the head of each standoff so that the board (1) is not locked, but the board is still attached to the standoff.
Remove the board (1) from all standoffs at the same time. Installation Procedure
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in a static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Position the board (1) in the cabinet over the white standoffs that are connected to the left panel. Install the board (1). Verify that all the standoffs are locked into the correct position.
Connect the wire connectors. Verify the labeling of each connector for proper placement. Refer to Illustration 2.
Calibrate the AC Interface Board. Refer to Systems Operation, Testing and Adjusting, UENR3954, "AC Voltage - Calibrate", Systems Operation, Testing and Adjusting, UENR3954, "AC Output Current - Calibrate", Systems Operation, Testing and Adjusting, UENR3954, "System Voltage - Calibrate", and Systems Operation, Testing and Adjusting, UENR3954, "System Output Current - Calibrate".
Table 1
Fuse Type
ACI-F1 250 VAC 5 A
ACI-F2 250 VAC 5 A
ACI-F3 250 VAC 5 A
ACI-F4 250 VAC 5 A
ACI-F6 250 VAC 2 A
Illustration 1 g01277041
(1) AC Interface (ACI) board The AC Interface (ACI) board (1) monitors the voltages on the following nodes: input, filter and output. Contactor K1 and contactor K2 are controlled via two relays that are located on the board (1).The MMS performs the following functions:
Controlling the K1 contactor
Controlling the K2 contactor
Monitoring the input current
Monitoring the output currentRemoval Procedure
Refer to Systems Operation, Testing and Adjusting, UENR3954, "Internal Component Preremoval Steps (Flywheel Cabinet)" in order to shut down the system and gain access to internal components.
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in a static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Illustration 2 g01277042
AC Interface (ACI) board
Disconnect all connectors. Verify each label for each connector for subsequent installation. Refer to Illustration 2.
Disconnect the white plastic standoffs that connect the board (1) to the left panel. Note: The board (1) must be removed from the standoffs without bending the board.
Compress the head of each standoff so that the board (1) is not locked, but the board is still attached to the standoff.
Remove the board (1) from all standoffs at the same time. Installation Procedure
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in a static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Position the board (1) in the cabinet over the white standoffs that are connected to the left panel. Install the board (1). Verify that all the standoffs are locked into the correct position.
Connect the wire connectors. Verify the labeling of each connector for proper placement. Refer to Illustration 2.
Calibrate the AC Interface Board. Refer to Systems Operation, Testing and Adjusting, UENR3954, "AC Voltage - Calibrate", Systems Operation, Testing and Adjusting, UENR3954, "AC Output Current - Calibrate", Systems Operation, Testing and Adjusting, UENR3954, "System Voltage - Calibrate", and Systems Operation, Testing and Adjusting, UENR3954, "System Output Current - Calibrate".
Table 1
Fuse Type
ACI-F1 250 VAC 5 A
ACI-F2 250 VAC 5 A
ACI-F3 250 VAC 5 A
ACI-F4 250 VAC 5 A
ACI-F6 250 VAC 2 A
Cat SIS web machinery list:
Parts dowel Caterpillar catalog:
4M3122
DOWEL
657B, 666, 977H, 977K, 977L, D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL
657B, 666, 977H, 977K, 977L, D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL
1H0525
DOWEL
583H, 594, 594H, D5, D5B, D8H, D9E, D9G, D9H
583H, 594, 594H, D5, D5B, D8H, D9E, D9G, D9H
2D0874
DOWEL
128, 583K, 950, 951, 955K, 955L, 966C, D8H, D8K
128, 583K, 950, 951, 955K, 955L, 966C, D8H, D8K
4F6154
DOWEL
120B, 12E, 12F, 140, 140B, 14E, 571G, 621, 621B, 623B, 627, 627B, 631C, 631E, 631G, 633D, 633E II, 637D, 637E, 641, 641B, 650B, 651, 651E, 657, 657B, 657E, 657G, 666, 955H, 983, D7F
120B, 12E, 12F, 140, 140B, 14E, 571G, 621, 621B, 623B, 627, 627B, 631C, 631E, 631G, 633D, 633E II, 637D, 637E, 641, 641B, 650B, 651, 651E, 657, 657B, 657E, 657G, 666, 955H, 983, D7F
1M5156
DOWEL
571G, 572G, 983, 983B, D10, D7F, D7G, D7G2
571G, 572G, 983, 983B, D10, D7F, D7G, D7G2
8H1130
DOWEL
572G, 583H, 980, 980B, 983, D7F, D7G, D7G2, D8H
572G, 583H, 980, 980B, 983, D7F, D7G, D7G2, D8H
2F7770
DOWEL
561B, 977D, D8H, D8K, D9G, D9H
561B, 977D, D8H, D8K, D9G, D9H
4F6165
DOWEL
120B, 12E, 12F, 140, 140B, 14E, 955H, 955K, 955L
120B, 12E, 12F, 140, 140B, 14E, 955H, 955K, 955L
3B8852
DOWEL
583K, 955K, 955L, D8H, D8K
583K, 955K, 955L, D8H, D8K
2M4537
DOWEL
16, 571G, 572G, 983, 983B, D7F, D7G, D7G2
16, 571G, 572G, 983, 983B, D7F, D7G, D7G2
5H3262
DOWEL
571G, 572G, 983, 983B, D7F, D7G, D7G2
571G, 572G, 983, 983B, D7F, D7G, D7G2
5S4033
DOWEL
583K, D8H, D8K
583K, D8H, D8K
3B2225
DOWEL
127, 12E, 12F, 14E, 16, 24, 25, 3181, 3192, 46, 528, 54, 571G, 572G, 583H, 621, 7251, 7261, 768B, 769, 772, 773, 773B, 824, 824B, 825B, 826B, 854G, 854K, 931, 931B, 950, 955C, 955H, 977K, 977L, 983, 9...
127, 12E, 12F, 14E, 16, 24, 25, 3181, 3192, 46, 528, 54, 571G, 572G, 583H, 621, 7251, 7261, 768B, 769, 772, 773, 773B, 824, 824B, 825B, 826B, 854G, 854K, 931, 931B, 950, 955C, 955H, 977K, 977L, 983, 9...
3L5791
DOWEL
D342C, G343
D342C, G343
7B5416
DOWEL
12E, 561B, 594, 955H, D320A, D342C, D353C, D4D, D9E, D9G, D9H
12E, 561B, 594, 955H, D320A, D342C, D353C, D4D, D9E, D9G, D9H
4L5913
DOWEL
D342C, D343, D348, D349, D353C, D379A, D398, D399
D342C, D343, D348, D349, D353C, D379A, D398, D399
4L3566
DOWEL
D342, D342C, G342C
D342, D342C, G342C
6H3257
DOWEL
16, 1693, 657, 769, 988, D343
16, 1693, 657, 769, 988, D343
5H1056
DOWEL
594H, 657, 769, 824, 834, D326F, D337F, D343, D353C, D9G, D9H
594H, 657, 769, 824, 834, D326F, D337F, D343, D353C, D9G, D9H
7B0537
DOWEL
D379B, D398, D398A, D398B, D399, G379, G398, G399
D379B, D398, D398A, D398B, D399, G379, G398, G399
3H3130
DOWEL
594, 631C, 769, 769C, 931, 955H, 988, D343, D353C, D9E, D9G, D9H
594, 631C, 769, 769C, 931, 955H, 988, D343, D353C, D9E, D9G, D9H
3H7935
DOWEL
594, D353C, D9E, D9G, D9H
594, D353C, D9E, D9G, D9H
8M1063
DOWEL
1676, 1693, 621, 631C, 657, 769, 824, 983, D336, D349, G343
1676, 1693, 621, 631C, 657, 769, 824, 983, D336, D349, G343
7S3580
DOWEL (1.25" LONG)
16, 1693, 631C, 657B, 769, 983, D343, G343
16, 1693, 631C, 657B, 769, 983, D343, G343