Information:
Test Three
Check the resistance and the continuity between the flow tube electrodes and the flow meter.
Illustration 1 g00892490
Remove enough piping or the flow meter in order to gain access to flow tube electrodes (1) .
Illustration 2 g00892831
Remove the cover plate from the transmitter for the flow meter in order to expose circuit board (2) .
Disconnect plug P-100 (3) from the connector for the circuit board.
Illustration 3 g00892834
Set Tooling (A) to measure the resistance (ohms).
Check the upper flow tube electrode by connecting one multimeter lead to the outer black wire in plug P-100 (5). Connect the other lead to the upper electrode. The upper electrode is in tube (6). The reading should be 60 20,000 Ohms. If there is no reading, an open in the circuit exists and the flow meter should be replaced.
Illustration 4 g00892835
Check the lower flow tube electrode by connecting one multimeter lead at the outer red wire in plug P-100 (5). Connect the other lead to the lower electrode. The lower electrode is inside tube (6). The reading should be 60 20,000 Ohms. If there is no reading, an open in the circuit exists and the flow meter should be replaced.
Check the resistance and the continuity between the flow tube electrodes and the flow meter.
Illustration 1 g00892490
Remove enough piping or the flow meter in order to gain access to flow tube electrodes (1) .
Illustration 2 g00892831
Remove the cover plate from the transmitter for the flow meter in order to expose circuit board (2) .
Disconnect plug P-100 (3) from the connector for the circuit board.
Illustration 3 g00892834
Set Tooling (A) to measure the resistance (ohms).
Check the upper flow tube electrode by connecting one multimeter lead to the outer black wire in plug P-100 (5). Connect the other lead to the upper electrode. The upper electrode is in tube (6). The reading should be 60 20,000 Ohms. If there is no reading, an open in the circuit exists and the flow meter should be replaced.
Illustration 4 g00892835
Check the lower flow tube electrode by connecting one multimeter lead at the outer red wire in plug P-100 (5). Connect the other lead to the lower electrode. The lower electrode is inside tube (6). The reading should be 60 20,000 Ohms. If there is no reading, an open in the circuit exists and the flow meter should be replaced.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts drawbar Caterpillar catalog:
1876167
DRAWBAR AR
325B L
325B L
5R7067
DRAWBAR GROUP
130G
130G
1111895
DRAWBAR GP
M312, M315, M318, M320
M312, M315, M318, M320
1124522
DRAWBAR GP
135H, 135H NA
135H, 135H NA
1273022
DRAWBAR GP
45, 55
45, 55
1876170
DRAWBAR AR
322B L
322B L
2C9554
DRAWBAR GP
120H
120H
1077235
DRAWBAR GP
561M, 561N, D5M, D5N
561M, 561N, D5M, D5N