Information:
Illustration 1 g00841253
Schematic for Sensor Supply VoltageThis diagnostic code is recorded when the power train electronic control module (ECM) reads the voltage of the sensor supply circuit as higher than normal. Possible causes of this diagnostic code are listed:
The output of sensor supply to battery has shorted.
The torque converter speed sensor is faulty or the transmission oil temperature sensor is faulty.System Response:The machine response is listed:
The lockup clutch is disabled.
Hesitation during direction shifts.
Calibrations will not function.Test Step 1. CHECK FOR THE CORRECT VOLTAGE AT THE ECM.
Turn the disconnect switch and the key start switch to the ON position.
Check the voltage at the ECM connector from contact J2-12 (sensor supply) to contact J1-16 (ground) or contact J2-9 (sensor supply) to contact J1-15 (ground). Use the 7X-1710 Cable probes to measure the voltage. Do NOT disconnect the machine harness from the ECM.Expected Result:The voltage is 8.0 0.5 DCV or the voltage is 10.0 0.5 DCV.Results:
OK - The voltage is 8.0 or 0.5 DCV or the voltage is 10.0 0.5 DCV. The sensor supply voltage is correct. Verify that the diagnostic code is present. If the diagnostic code is still present, the ECM has failed. Replace the ECM.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NOT OK - Voltage is greater than 8.0 or 10.0 0.5 DCV. The sensor supply voltage is NOT correct. Proceed to test step 2.Test Step 2. CHECK THE HARNESS FOR A SHORT TO THE +BATTERY CIRCUIT.
The disconnect switch and the key start switch remain in the ON position.
Disconnect the machine harness from the ECM.
At the machine harness connector for the ECM, measure the voltage from connector contact J2-12 (sensor supply) to contact J1-16 (ground) or contact J2-9 (sensor supply) to contact J1-15 (ground).Expected Result:The voltage is 0.0 0.5 DCV.Results:
OK - The voltage is 0.0 0.5 DCV. The voltage is correct. The ECM has failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NOT OK - Voltage is NOT 0.0 0.5 DCV. The harness has failed.Repair: The machine harness is shorted to the +battery circuit. Repair the machine harness or replace the machine harness. Stop.
Caterpillar parts catalog:
Parts drawbar Caterpillar catalog:
2651090
DRAWBAR & YOKE AS
120M, 120M 2
120M, 120M 2
2534651
DRAWBAR & YOKE AS
12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 160M, 160M 2, 160M 3, 160M 3 AWD
12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 160M, 160M 2, 160M 3, 160M 3 AWD
4178162
DRAWBAR & YOKE AS
120K, 120K 2
120K, 120K 2
4178159
DRAWBAR & YOKE AS
120K, 120K 2
120K, 120K 2
3740615
DRAWBAR & YOKE AS
120K, 120K 2
120K, 120K 2
3418350
DRAWBAR & YOKE AS
120K, 120K 2
120K, 120K 2
3723398
DRAWBAR & YOKE AS
12K, 140K, 140K 2, 160K
12K, 140K, 140K 2, 160K
3387506
DRAWBAR & YOKE AS
12K, 140K, 140K 2, 160K
12K, 140K, 140K 2, 160K