3004246 DRIVE GP-FINAL Caterpillar parts
304C CR, 305D CR, 305E
Rating:
Alternative (cross code) number:
CA3004246
300-4246
3004246
CA3004246
300-4246
3004246
Weight: 115 pounds 52 kg.
MINI HYD EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
WZCNLXLX Hydraulic Final Drive Travel Motor 3004246 300-4246 for Caterpillar 304 304.5 305 306 Excavator
WZCNLXLX Item Name:Hydraulic Final Drive Travel Motor || Item Number:3004246 300-4246 || Application:for Caterpillar 304 304.5 305 306 Excavator || Note: If you are unsure if the product is suitable.In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please check the product image and part number to ensure it is the product you want. || Tip: Please contact us - we are a professional sales team and we have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here.
WZCNLXLX Item Name:Hydraulic Final Drive Travel Motor || Item Number:3004246 300-4246 || Application:for Caterpillar 304 304.5 305 306 Excavator || Note: If you are unsure if the product is suitable.In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please check the product image and part number to ensure it is the product you want. || Tip: Please contact us - we are a professional sales team and we have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here.
Information:
Introduction
Standard floor-standing switchgear units incorporate a comprehensive system of components for generator set control, monitoring and protection. This system's approach to genset management results in unsurpassed reliability, capability and performance for many applications.Switchgear includes:* Caterpillar EMCP II Controls* Fix-mounted Circuit Breaker* Governor Controls* NEMA 1 Floorstanding EnclosureAll these "standard" features-and the many functions they represent-are conveniently housed in a NEMA 1 cabinet for indoor use. The cabinet is fabricated with steel barriers between power and control sections.Location of Components
(1) Synchroscope (optional) (2) Kilowatt Meter (optional) or Killowatt Hour Meter (optional) (3) Power Factor Meter (optional) (4) Kilovar Meter (optional) (5) Alarm Module (6) Generator Set Controller (7) Status Lamps (optional) (8) Synchronizing Switch & Lights (optional) (9) Engine Control Switch (10) Emergency Stop Button (11) Alarm Control Switch (12) Breaker Control Switch (optional) (13) Speed Adjust Rheostat (14) Voltage Adjust Potentiometer (15) Battery Charger Controls (optional) (16) Accessory Circuit Breakers (optional)The Caterpillar Switchgear unit depicted on this page shows the location of externally facing components. They are:* Generator Set Control (GSC)* Alarm Module* Alarm Control Switch* Voltage Adjust Rheostat* Engine Control Switch* Emergency Stop Push-Button* Speed Adjust Potentiometer* Synchroscope** Synchronizing Switch & Lights** Kilovar Meter** Kilowatt Hour Meter** Power Factor Meter** Breaker Control Switch** Battery Charger Controls** Accessory Circuit Breakers **OPTIONAL
(1) Auto Synchronizer (optional) (2) Annunicator Modules (3) Electronic Governor (optional) (4) Control Relays (5) Insulated Case Circuit Breaker (6) Battery Charger (optional) (7) Customer Interface Module (optional) (8) Jacket Water Heater Cntrl Circuit (optional) (9) General Strip Heater Cntrl Circuit (optional) (10) AC Transformer Box (11) Potential Transformer (12) Protective Relays (13) Customer Connection PointsInside the cabinet, you will find these components and subsystems:* Synchronizing/Paralleling Features** Annunicator Modules* Electronic Governor** Control Relays* Insulated Case Circuit Breaker* Battery Charger** Customer Interface Module** Jacket Water Heater Cntrl Circuit** General Strip Heater Cntrl Circuit** AC Transformer Box* Potential Transformer* Protective Relays*OPTIONALMain Components
The main components of Caterpillar Switchgear units are the Generator Set Controller, Instrument Panel Switches and the Circuit Breaker.
GSC Display Area With Service Mode Descriptions Of Keypad
(1) Dedicated shutdown indicators. (2) Fault shutdown indicator. (3) Fault alarm indicator. (4) Upper display. (5) Lower display. (6) Keypad.Caterpillar's Electronic Modular Control Panel II (EMCP II) is at the core of switchgear operations. In turn, the EMCP II has as its main component the generator set control (GSC). The GSC is designed to operate when powered by only 24 DCV or 32 DCV battery systems. The GSC monitors and controls many of the generator set (genset) functions. The functions and features of the GSC are:* Controls normal starting and stopping of the engine.* Shows engine conditions and generator output information on two displays. The displays also show fault codes and GSC programming information.* Monitors the system for faults. If a fault occurs, the GSC performs a controlled fault shutdown or provides a fault alarm annunciation. The GSC uses indicators and displays to describe the fault to the operator or service technician.* Contains programmable features for certain applications or customer requirements.Fault Indicators
The eight
Standard floor-standing switchgear units incorporate a comprehensive system of components for generator set control, monitoring and protection. This system's approach to genset management results in unsurpassed reliability, capability and performance for many applications.Switchgear includes:* Caterpillar EMCP II Controls* Fix-mounted Circuit Breaker* Governor Controls* NEMA 1 Floorstanding EnclosureAll these "standard" features-and the many functions they represent-are conveniently housed in a NEMA 1 cabinet for indoor use. The cabinet is fabricated with steel barriers between power and control sections.Location of Components
(1) Synchroscope (optional) (2) Kilowatt Meter (optional) or Killowatt Hour Meter (optional) (3) Power Factor Meter (optional) (4) Kilovar Meter (optional) (5) Alarm Module (6) Generator Set Controller (7) Status Lamps (optional) (8) Synchronizing Switch & Lights (optional) (9) Engine Control Switch (10) Emergency Stop Button (11) Alarm Control Switch (12) Breaker Control Switch (optional) (13) Speed Adjust Rheostat (14) Voltage Adjust Potentiometer (15) Battery Charger Controls (optional) (16) Accessory Circuit Breakers (optional)The Caterpillar Switchgear unit depicted on this page shows the location of externally facing components. They are:* Generator Set Control (GSC)* Alarm Module* Alarm Control Switch* Voltage Adjust Rheostat* Engine Control Switch* Emergency Stop Push-Button* Speed Adjust Potentiometer* Synchroscope** Synchronizing Switch & Lights** Kilovar Meter** Kilowatt Hour Meter** Power Factor Meter** Breaker Control Switch** Battery Charger Controls** Accessory Circuit Breakers **OPTIONAL
(1) Auto Synchronizer (optional) (2) Annunicator Modules (3) Electronic Governor (optional) (4) Control Relays (5) Insulated Case Circuit Breaker (6) Battery Charger (optional) (7) Customer Interface Module (optional) (8) Jacket Water Heater Cntrl Circuit (optional) (9) General Strip Heater Cntrl Circuit (optional) (10) AC Transformer Box (11) Potential Transformer (12) Protective Relays (13) Customer Connection PointsInside the cabinet, you will find these components and subsystems:* Synchronizing/Paralleling Features** Annunicator Modules* Electronic Governor** Control Relays* Insulated Case Circuit Breaker* Battery Charger** Customer Interface Module** Jacket Water Heater Cntrl Circuit** General Strip Heater Cntrl Circuit** AC Transformer Box* Potential Transformer* Protective Relays*OPTIONALMain Components
The main components of Caterpillar Switchgear units are the Generator Set Controller, Instrument Panel Switches and the Circuit Breaker.
GSC Display Area With Service Mode Descriptions Of Keypad
(1) Dedicated shutdown indicators. (2) Fault shutdown indicator. (3) Fault alarm indicator. (4) Upper display. (5) Lower display. (6) Keypad.Caterpillar's Electronic Modular Control Panel II (EMCP II) is at the core of switchgear operations. In turn, the EMCP II has as its main component the generator set control (GSC). The GSC is designed to operate when powered by only 24 DCV or 32 DCV battery systems. The GSC monitors and controls many of the generator set (genset) functions. The functions and features of the GSC are:* Controls normal starting and stopping of the engine.* Shows engine conditions and generator output information on two displays. The displays also show fault codes and GSC programming information.* Monitors the system for faults. If a fault occurs, the GSC performs a controlled fault shutdown or provides a fault alarm annunciation. The GSC uses indicators and displays to describe the fault to the operator or service technician.* Contains programmable features for certain applications or customer requirements.Fault Indicators
The eight
Caterpillar SIS machinery equipment:
Caterpillar SIS
304 C CR Mini Hydraulic Excavator FPK00001-UP (MACHINE) POWERED BY S4Q2T Engine »
300-4246
DRIVE GP-FINAL
305D Mini Hydraulic Excavator XER00001-UP (MACHINE) POWERED BY S4Q2T Engine »
300-4246
DRIVE GP-FINAL
305E Mini Hydraulic Excavator XFA00001-UP (MACHINE) POWERED BY C2.4 Engine »
300-4246
DRIVE GP-FINAL
305E Mini Hydraulic Excavator WDL00001-UP (MACHINE) »
300-4246
DRIVE GP-FINAL
305E Mini Hydraulic Excavator XSC00001-UP (MACHINE) »
300-4246
DRIVE GP-FINAL
Caterpillar parts catalog:
Parts drive Caterpillar catalog:
2258809
DRIVE GP-AUGER
305.5E, 305E, 308E2 CR, A26B
305.5E, 305E, 308E2 CR, A26B
2305578
DRIVE GP-AUGER
305.5E, 305E, A26B
305.5E, 305E, A26B
3099247
DRIVE GP-FINAL
304C CR, 305D CR, 305E
304C CR, 305D CR, 305E
2666397
DRIVE GP-FINAL
304C CR
304C CR
2821534
DRIVE GP-SWING
304C CR, 305.5D, 305.5E, 305C CR, 305D CR, 305E
304C CR, 305.5D, 305.5E, 305C CR, 305D CR, 305E
1066409
DRIVE GP-POWER TAKE-OFF
939, D5C III
939, D5C III
3500655
DRIVE GP-FAN
3.4B IOPU, C3.4B, CB-44B, CB-54B, CD-54B
3.4B IOPU, C3.4B, CB-44B, CB-54B, CD-54B
3255669
DRIVE GP-FAN
C2.2
C2.2
2915467
DRIVE GP-DRUM
CS-533E
CS-533E
3311182
DRIVE GP-FINAL
AP1055E, BG1055E
AP1055E, BG1055E
2129822
DRIVE GP-FAN
TH62, TH63, TH82, TH83
TH62, TH63, TH82, TH83
1184718
DRIVE GP-FLEXIBLE COUPLING
416B, 426B, 428B, 436B, 438B
416B, 426B, 428B, 436B, 438B