Procedure To Measure The SCA In Water-Only Coolant Mixture
The 8T5296 Conditioner Test Kit can be used to evaluate the SCA concentration in a water-only coolant mixture with the following modifications to the test procedure. The test procedure, as defined on the card enclosed with the test kit, must be modified as follows.
The information in italics is the modifications to the test procedure on the card.Test Procedure:
1. Fill the dropper pipet to the 1.0 mL mark with the coolant to be tested.2. Dispense the 1.0 mL coolant sample from the dropper pipet into the empty vial. (Be sure the vial is clean.)3. Add tap water to the vial up to the 20 mL mark. A 20 mL mark IS defined on the vial. (It is on the right side of vial when looking at the normal 10 mL fill level marking.) Replace the vial cap and shake. Now pour out the mixture until 10 mL remains in the bottle. Use the dropper pipet as an aid to remove liquid to the 10 mL level.4. Add 2 or 3 drops of red SOLUTION B to the vial and swirl to mix.5. Add 1 drop of orange SOLUTION A to the vial and swirl the mix. Continue this procedure of adding 1 drop of SOLUTION A and swirling until the mixture in the vial changes color from red to pale gray, green, or blue. Record the number of drops of SOLUTION A required to cause the color change. With the defined procedure, the 6 to 8% SCA concentration will produce a 20 to 27 drop range. Less drops indicates an under concentration of SCA and more drops indicates an over concentration. Adjust the SCA concentration until the test produces a color change in the 20 to 27 drop range. For more consistent results in the number of drops required to get the color change, hold the SOLUTION A bottle vertically over the vial as the drops are added. This bottle position will provide a more consistent drop size and thus will provide better test results.
The 8T5296 Conditioner Test Kit can be used to evaluate the SCA concentration in a water-only coolant mixture with the following modifications to the test procedure. The test procedure, as defined on the card enclosed with the test kit, must be modified as follows.
The information in italics is the modifications to the test procedure on the card.Test Procedure:
1. Fill the dropper pipet to the 1.0 mL mark with the coolant to be tested.2. Dispense the 1.0 mL coolant sample from the dropper pipet into the empty vial. (Be sure the vial is clean.)3. Add tap water to the vial up to the 20 mL mark. A 20 mL mark IS defined on the vial. (It is on the right side of vial when looking at the normal 10 mL fill level marking.) Replace the vial cap and shake. Now pour out the mixture until 10 mL remains in the bottle. Use the dropper pipet as an aid to remove liquid to the 10 mL level.4. Add 2 or 3 drops of red SOLUTION B to the vial and swirl to mix.5. Add 1 drop of orange SOLUTION A to the vial and swirl the mix. Continue this procedure of adding 1 drop of SOLUTION A and swirling until the mixture in the vial changes color from red to pale gray, green, or blue. Record the number of drops of SOLUTION A required to cause the color change. With the defined procedure, the 6 to 8% SCA concentration will produce a 20 to 27 drop range. Less drops indicates an under concentration of SCA and more drops indicates an over concentration. Adjust the SCA concentration until the test produces a color change in the 20 to 27 drop range. For more consistent results in the number of drops required to get the color change, hold the SOLUTION A bottle vertically over the vial as the drops are added. This bottle position will provide a more consistent drop size and thus will provide better test results.
Caterpillar parts catalog:
Parts edge Caterpillar catalog:
1778197
EDGE AS
315B, 315C, 315D L, 318D L, 318D2 L
315B, 315C, 315D L, 318D L, 318D2 L
1778210
EDGE AS
315B, 315C
315B, 315C
1778223
EDGE AS
315B, 315C
315B, 315C
1778236
EDGE AS
315B, 315C, 315D L
315B, 315C, 315D L
1778249
EDGE AS
315B, 315B FM L, 315C
315B, 315B FM L, 315C
1483139
EDGE AS
315B
315B
1483342
EDGE AS
315B
315B
1499421
EDGE AS
315B
315B
1499412
EDGE AS
315B
315B
1499412
EDGE AS
315B
315B
1499421
EDGE AS
315B
315B
1483342
EDGE AS
315B
315B
1483139
EDGE AS
315B
315B
1175377
EDGE AS
315
315
1175386
EDGE AS
315
315
1U0132
EDGE
D6H, D6R, D6R II
D6H, D6R, D6R II
1U0131
EDGE
D6H, D6R, D6R II
D6H, D6R, D6R II
4T2948
EDGE-CUTTING
D6R, D6R II, D7G, D7G2
D6R, D6R II, D7G, D7G2
1099093
EDGE-CUTTING
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
4T9563
Edge
943
943
4T8091
Edge-End
910G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 924K, 928F, 928G, 928HZ, 930G, 930K, 936, 936F, 938F, 938G, 938G II, 938H, 938K, 939, 939C, 943, 950K, 953, 953C, 953D, 962K, IT12B, IT14G, IT18F, IT24F, IT...
910G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 924K, 928F, 928G, 928HZ, 930G, 930K, 936, 936F, 938F, 938G, 938G II, 938H, 938K, 939, 939C, 943, 950K, 953, 953C, 953D, 962K, IT12B, IT14G, IT18F, IT24F, IT...