1690385 EDGE-CUTTING Caterpillar parts
MP15, P215, P360, S115, S305, S465, VHC-30, VHP-30, VHS-50, VPS-35, VT30, VT50
Rating:
Alternative (cross code) number:
CA1690385
169-0385
1690385
CA1690385
169-0385
1690385
Weight: 7 pounds 3 kg.
CRUSHER, SHEAR-STRAIGHT,
This part in 2 request:
Show.
This information for suppliers only!
2018-07-11
2017-09-19
Compatible equipment models: 1690385:
Information:
Operational Information Of The Oil Cooler Control Monitor System
The Oil Cooler Control Monitor System provides monitoring information for the rear power train cooling filtration system, and controls a two speed fan based on the monitoring inputs.There are four inputs to the control on EMS trucks and three inputs to the control on VIMS trucks. The inputs are: differential oil temperature (on VIMS trucks this is already installed and obtained over the data link), cooler/filtration pump outlet pressure, rear differential oil level, and rear power train filter plug switch.On VIMS trucks, the control supplies this data to VIMS for display, while on EMS trucks, the monitor provides visual output for:1. High Differential Oil Temperature Activated when Differential Temperature > 124° C (255.2° F) and Deactivated2. Very High Differential Oil Temperature Activated when Differential Temperature > 135° C (275.0° F) and Deactivated3. Filter Plugged Activated when Differential Temperature > 60° C (140.0° F) and Filter Switch Open > Approximately 20 Seconds4. Low Pump Pressure Activated when Pump Pressure kPa (5 psi) and Speed > 24 km/h (14.9 mph)5. High Pump Pressure Activated when Pump Pressure > 689.00 kPa (100 psi) and Ground Speed km/h (1.2 mph)6. Fan Low Driver Failure/Short7. Fan Hi Driver Failure/Short8. System Voltage Low Activated when System Voltage VDC for 5 seconds9. Low Differential Oil Level Activated when Level Switch Open for > Approximately 20 Seconds on Startup or Bed RaiseThe digital display defaults to differential oil temperature. The display can be toggled using the operator mode switch to obtain pulp outlet pressure and total fan running hours. This operation, and servicing is identical to that described in SENR6717.The control/monitor differs from the SENR6717 operation in the area of operator alarms. The two output drivers on the control are used to drive two relays. The fan low relay provides power to a dropping resistor which is connected to the motor. The fan high relay provides power directly to the motor. The fan will operate at approximately 1/2 speed at low speed, and from 1600-2300 RPM at high speed depending on system voltage.The fan LOW relay is turned ON under the following conditions:1. Any time fan HI relay is turned ON.2. For one minute after the fan HI relay is turned OFF.3. For at least five minutes after it has been turned ON.4. If differential temperature is greater than 65° C (149.0° F) and until differential temperature fall below 57° C (134.6° F).The fan HI relay is turned ON under the following conditions:1. For at least five minutes after it has been turned ON.2. If machine speed greater than 32.20 km/h (20 Mph) and differential temperature greater than 65° C (149.0° F).3. If differential temperature is greater than 96° C (204.8° F) and until the differential temperature falls below 57° C (134.6° F).Both relays will be turned OFF any time the system voltage falls below 23 VDC. Both relays will also be turned OFF when the actual gear is neutral after they have been ON for at least
The Oil Cooler Control Monitor System provides monitoring information for the rear power train cooling filtration system, and controls a two speed fan based on the monitoring inputs.There are four inputs to the control on EMS trucks and three inputs to the control on VIMS trucks. The inputs are: differential oil temperature (on VIMS trucks this is already installed and obtained over the data link), cooler/filtration pump outlet pressure, rear differential oil level, and rear power train filter plug switch.On VIMS trucks, the control supplies this data to VIMS for display, while on EMS trucks, the monitor provides visual output for:1. High Differential Oil Temperature Activated when Differential Temperature > 124° C (255.2° F) and Deactivated2. Very High Differential Oil Temperature Activated when Differential Temperature > 135° C (275.0° F) and Deactivated3. Filter Plugged Activated when Differential Temperature > 60° C (140.0° F) and Filter Switch Open > Approximately 20 Seconds4. Low Pump Pressure Activated when Pump Pressure kPa (5 psi) and Speed > 24 km/h (14.9 mph)5. High Pump Pressure Activated when Pump Pressure > 689.00 kPa (100 psi) and Ground Speed km/h (1.2 mph)6. Fan Low Driver Failure/Short7. Fan Hi Driver Failure/Short8. System Voltage Low Activated when System Voltage VDC for 5 seconds9. Low Differential Oil Level Activated when Level Switch Open for > Approximately 20 Seconds on Startup or Bed RaiseThe digital display defaults to differential oil temperature. The display can be toggled using the operator mode switch to obtain pulp outlet pressure and total fan running hours. This operation, and servicing is identical to that described in SENR6717.The control/monitor differs from the SENR6717 operation in the area of operator alarms. The two output drivers on the control are used to drive two relays. The fan low relay provides power to a dropping resistor which is connected to the motor. The fan high relay provides power directly to the motor. The fan will operate at approximately 1/2 speed at low speed, and from 1600-2300 RPM at high speed depending on system voltage.The fan LOW relay is turned ON under the following conditions:1. Any time fan HI relay is turned ON.2. For one minute after the fan HI relay is turned OFF.3. For at least five minutes after it has been turned ON.4. If differential temperature is greater than 65° C (149.0° F) and until differential temperature fall below 57° C (134.6° F).The fan HI relay is turned ON under the following conditions:1. For at least five minutes after it has been turned ON.2. If machine speed greater than 32.20 km/h (20 Mph) and differential temperature greater than 65° C (149.0° F).3. If differential temperature is greater than 96° C (204.8° F) and until the differential temperature falls below 57° C (134.6° F).Both relays will be turned OFF any time the system voltage falls below 23 VDC. Both relays will also be turned OFF when the actual gear is neutral after they have been ON for at least
Cat SIS web machinery list:
Parts edge Caterpillar catalog:
1964133
EDGE-CUTTING
S305, S465, VHS-50
S305, S465, VHS-50
2274166
EDGE-CUTTING
S305, S365B, S365C, VHS-50, VHS-60/3, VHS-60/4
S305, S365B, S365C, VHS-50, VHS-60/3, VHS-60/4
2274167
EDGE-CUTTING
S305, S365B, S365C, VHS-50, VHS-60/3, VHS-60/4
S305, S365B, S365C, VHS-50, VHS-60/3, VHS-60/4
2274168
EDGE-CUTTING
S305, VHS-50
S305, VHS-50
2341361
EDGE-CUTTING
S305, S365B, VHS-50, VHS-60/3
S305, S365B, VHS-50, VHS-60/3
2349154
EDGE-CUTTING
S305, VHS-50
S305, VHS-50
2349156
EDGE-CUTTING
S305, VHS-50
S305, VHS-50
2349157
EDGE-CUTTING
S305, VHS-50
S305, VHS-50
2349159
EDGE-END
S305, VHS-50
S305, VHS-50
2362205
EDGE-CUTTING
S305, S365B, VHS-50, VHS-60/3
S305, S365B, VHS-50, VHS-60/3
2362206
EDGE-CUTTING
S305, S365B, VHS-50, VHS-60/3
S305, S365B, VHS-50, VHS-60/3
2362207
EDGE-CUTTING
S305, S365B, VHS-50, VHS-60/3
S305, S365B, VHS-50, VHS-60/3
1917647
EDGE-CUTTING
CR20
CR20
1917648
EDGE-CUTTING
CR20
CR20
1917646
EDGE-CUTTING
CR20
CR20
1696071
EDGE-CUTTING
MP15, S115, S305, VHS-50, VPS-35, VT30, VT50
MP15, S115, S305, VHS-50, VPS-35, VT30, VT50
1696066
EDGE-CUTTING
MP15, MP318, VT30, VT50
MP15, MP318, VT30, VT50
1696057
EDGE-CUTTING
MP15, MP318, VT30, VT50
MP15, MP318, VT30, VT50
1696056
EDGE-CUTTING
MP15, VT30, VT50
MP15, VT30, VT50
1696055
EDGE-CUTTING
MP15, VT30, VT50
MP15, VT30, VT50
1697117
EDGE-CUTTING
MP15, P215, P360, S115, S305, VHC-30, VHP-30, VHS-50, VPS-35, VT30, VT50
MP15, P215, P360, S115, S305, VHC-30, VHP-30, VHS-50, VPS-35, VT30, VT50