Illustration 1 g02672516
Connections of the Fuel Level Sender
This diagnostic code is associated with the Fuel Level Sender. The FMI 03 means that the Implement ECM has determined that the voltage of the sender circuit is above normal.The possible causes of this diagnostic code are listed below:
There is an open in the sender circuit.
The signal circuit is shorted to another voltage source.
The sender has failed.
The ECM has failed. This condition is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected.Test Step 1. CHECK THE SENDER CIRCUIT FOR AN OPEN CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector from the sensor.
At the machine harness connector for the sender, connect a jumper wire from the signal contact 1 (wire 447-PK(Pink)) to frame ground.
Turn the key start switch and the disconnect switch to the ON position.
Observe the status of the active CID 0096 FMI 03 diagnostic code. Expected Result:The active CID 0096 FMI 03 diagnostic code is no longer active. A CID 0096 FMI 04 diagnostic code becomes active when the signal wire is grounded.Results:
YES - The active CID 0096 FMI 03 diagnostic code is no longer active. A CID 0096 FMI 04 diagnostic code has been activated after the signal wires is grounded. Proceed to Test Step 2.
NO - The CID 0096 FMI 03 diagnostic code remains active. The status of the active diagnostic code does not change when the signal wire is grounded. There is an open or a poor connection in the signal wire.Repair: Check
Parts edge Caterpillar catalog:
2174820
EDGE-
Caterpillar
Caterpillar
2174819
EDGE-
Caterpillar
Caterpillar
2174818
EDGE-
Caterpillar
Caterpillar
2174817
EDGE-
Caterpillar
Caterpillar
2174816
EDGE-
Caterpillar
Caterpillar
2174815
EDGE-
Caterpillar
Caterpillar
2174828
EDGE-
Caterpillar
Caterpillar
2174827
EDGE-
Caterpillar
Caterpillar
2174825
EDGE-
Caterpillar
Caterpillar
2174824
EDGE-
Caterpillar
Caterpillar
2174823
EDGE-
Caterpillar
Caterpillar
2174822
EDGE-
Caterpillar
Caterpillar