3662666 EDGE-CUTTING Caterpillar parts
G315B, G325B, VRG-40/2
Rating:
Alternative (cross code) number:
CA3662666
366-2666
3662666
CA3662666
366-2666
3662666
Weight: 112 pounds 51 kg.
GRAPPLE-DEM/SORT, GRAPPLE-WASTE HANDLING,
This part in 2 request:
Show.
This information for suppliers only!
2023-02-17
2023-02-01
Compatible equipment models: 3662666:
Information:
Removal Procedure
Table 1
Required Tools    
Tool     Part Number     Part Description     Qty    
A     138-7575     Link Brackets     2    
B     5P-1275     Lockwire (1)     4    
314-8478 Lockwire Tool     1    
( 1 ) Cut the lockwire to a length 200.0 mm (7.87 inch).Start By:
Perform the Electrical Shutdown and Voltage Discharge procedure.
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
Personal injury can result from hot coolant, steam and alkali.At operating temperature, engine coolant is hot and under pressure. The radiator and all lines to heaters or the engine contain hot coolant or steam. Any contact can cause severe burns.Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.
Refer to Operation and Maintenance Manual, "Cooling System Coolant (ELC) - Change" for the correct draining and filling procedures.
Illustration 1 g01849494
Note: Disconnect the negative battery cables first.
Disconnect cable assemblies (1) on the battery.
Illustration 2 g01826556
Remove bolt (2) .Note: Support cable assemblies (5) and (6) during the removal and installation procedure. Do not use an impact wrench to disconnect or connect cable assemblies (5) and (6) .
Disconnect hoses (3) and (7) . Disconnect harness assemblies (4) . Disconnect cable assemblies (5) and (6) .
Illustration 3 g01826560
Attach Tooling (A) and a suitable lifting device to accessory power converter (9) . The weight of accessory power converter (9) is approximately 36 kg (80 lb). Remove bolts (8) and accessory power converter (9) .Installation Procedure
Install accessory power converter (9) in the reverse order of removal.
Tighten the positive cable assembly (6) to a torque of 50 10 N m (37 7 lb ft).
Tighten cable assembly (5) to a torque of 30 7 N m (22 5 lb ft).
Illustration 4 g02059535
Install Tooling (B) in order to secure the harness assemblies (4) . Install Tooling (B) in a
Table 1
Required Tools    
Tool     Part Number     Part Description     Qty    
A     138-7575     Link Brackets     2    
B     5P-1275     Lockwire (1)     4    
314-8478 Lockwire Tool     1    
( 1 ) Cut the lockwire to a length 200.0 mm (7.87 inch).Start By:
Perform the Electrical Shutdown and Voltage Discharge procedure.
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
Personal injury can result from hot coolant, steam and alkali.At operating temperature, engine coolant is hot and under pressure. The radiator and all lines to heaters or the engine contain hot coolant or steam. Any contact can cause severe burns.Remove cooling system pressure cap slowly to relieve pressure only when engine is stopped and cooling system pressure cap is cool enough to touch with your bare hand.Do not attempt to tighten hose connections when the coolant is hot, the hose can come off causing burns.Cooling System Coolant Additive contains alkali. Avoid contact with skin and eyes.
Refer to Operation and Maintenance Manual, "Cooling System Coolant (ELC) - Change" for the correct draining and filling procedures.
Illustration 1 g01849494
Note: Disconnect the negative battery cables first.
Disconnect cable assemblies (1) on the battery.
Illustration 2 g01826556
Remove bolt (2) .Note: Support cable assemblies (5) and (6) during the removal and installation procedure. Do not use an impact wrench to disconnect or connect cable assemblies (5) and (6) .
Disconnect hoses (3) and (7) . Disconnect harness assemblies (4) . Disconnect cable assemblies (5) and (6) .
Illustration 3 g01826560
Attach Tooling (A) and a suitable lifting device to accessory power converter (9) . The weight of accessory power converter (9) is approximately 36 kg (80 lb). Remove bolts (8) and accessory power converter (9) .Installation Procedure
Install accessory power converter (9) in the reverse order of removal.
Tighten the positive cable assembly (6) to a torque of 50 10 N m (37 7 lb ft).
Tighten cable assembly (5) to a torque of 30 7 N m (22 5 lb ft).
Illustration 4 g02059535
Install Tooling (B) in order to secure the harness assemblies (4) . Install Tooling (B) in a
Caterpillar parts catalog:
Parts edge Caterpillar catalog:
2400196
EDGE
G325B, VRG-40/2
G325B, VRG-40/2
3401641
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3710964
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3544014
EDGE-CUTTING
G315B, G325B, VRG-40/2
G315B, G325B, VRG-40/2
3629464
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3677540
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3684115
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3684127
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3544014
EDGE-CUTTING
G315B, G325B, VRG-40/2
G315B, G325B, VRG-40/2
3710964
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3401641
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
2400196
EDGE
G325B, VRG-40/2
G325B, VRG-40/2
3597712
EDGE-CUTTING
S365C, VHS-60/4
S365C, VHS-60/4
3052321
EDGE-CUTTING
S365C, VHS-60/4
S365C, VHS-60/4
3651114
EDGE-CUTTING
CTV40
CTV40
4326630
EDGE-CUTTING
MP318
MP318
3684127
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3684115
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3677540
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2
3629464
EDGE-CUTTING
G325B, VRG-40/2
G325B, VRG-40/2