3357994 EJECTOR AS Caterpillar parts
773E, 773F, 775F
Rating:
Alternative (cross code) number:
CA3357994
335-7994
3357994
CA3357994
335-7994
3357994
Weight: 72 pounds 32 kg.
TRUCK,
Information:
These high vacuum pumps are used to remove the moisture from an air conditioner system before it is filled with refrigerant. See the instructions that follow for the correct maintenance and operation procedures.
Use only the correct electrical supply to operate the pump. Be sure the pump has a good electrical ground before operation is begun. Always use safety goggles during operation of the pump.
These vacuum pumps have a one year warranty against defect in materials and workmanship.Order Replacement Parts from:Kent-Moore Tool Division
Kent-Moore Corporation
1501 South Jackson Street
Jackson, Michigan, U.S.A. 49203
Attention: Diesel and Allied Products Order Desk
(1) Close exhaust valve (1), then start pump (2). Check the oil level in sight gauge (3). If the oil level is low, remove exhaust filter (4). With intake (5) closed and the pump running, add oil at the exhaust port until the gauge shows the correct level. Use only high vacuum pump oil; see the parts list. Use of any other oil in the pump will cancel the warranty.(2) After the pump is started, turn valve (1) one revolution counterclockwise. Operate the pump with valve (1) open until there is a vacuum indication of approximately 700 microns; then close valve (1) for the remainder of the evacuation procedure, approximately 25 to 30 minutes.If the rated vacuum cannot be gotten with the pump, check the pump oil; if contamination is found, change the oil. If there is a large increase in the oil level, there is probably too much moisture in the pump; the oil should be changed. To change the oil, the pump must be at normal temperature of operation. Open valve (6) and drain the oil. To drain additional oil, remove filter (4) and operate the pump a short time with the filter port held closed. Use the cup given with the pump to measure the correct amount of oil to be added.If the pump is to be flushed and cleaned, drain the oil and use only High Vacuum Pump Oil (see the parts list) to flush the pump. With valve (6) open, add four ounces (118.0) of oil into fitting (5) while the pump is in operation and the exhaust port under filter (4) is held closed. Follow this procedure until the oil from valve (6) is clean, then close valve (6) and fill the pump with fresh High Vacuum Pump Oil. Clean exhaust filter (4) in an oil solvent before it is again installed.Pump Motor Lubrication: After three years of normal or one year of heavy service, add a small amount of electric motor or SAE 10 oil to the motor bearings. DO NOT OVER OIL.Field Service Parts
Use only the correct electrical supply to operate the pump. Be sure the pump has a good electrical ground before operation is begun. Always use safety goggles during operation of the pump.
These vacuum pumps have a one year warranty against defect in materials and workmanship.Order Replacement Parts from:Kent-Moore Tool Division
Kent-Moore Corporation
1501 South Jackson Street
Jackson, Michigan, U.S.A. 49203
Attention: Diesel and Allied Products Order Desk
(1) Close exhaust valve (1), then start pump (2). Check the oil level in sight gauge (3). If the oil level is low, remove exhaust filter (4). With intake (5) closed and the pump running, add oil at the exhaust port until the gauge shows the correct level. Use only high vacuum pump oil; see the parts list. Use of any other oil in the pump will cancel the warranty.(2) After the pump is started, turn valve (1) one revolution counterclockwise. Operate the pump with valve (1) open until there is a vacuum indication of approximately 700 microns; then close valve (1) for the remainder of the evacuation procedure, approximately 25 to 30 minutes.If the rated vacuum cannot be gotten with the pump, check the pump oil; if contamination is found, change the oil. If there is a large increase in the oil level, there is probably too much moisture in the pump; the oil should be changed. To change the oil, the pump must be at normal temperature of operation. Open valve (6) and drain the oil. To drain additional oil, remove filter (4) and operate the pump a short time with the filter port held closed. Use the cup given with the pump to measure the correct amount of oil to be added.If the pump is to be flushed and cleaned, drain the oil and use only High Vacuum Pump Oil (see the parts list) to flush the pump. With valve (6) open, add four ounces (118.0) of oil into fitting (5) while the pump is in operation and the exhaust port under filter (4) is held closed. Follow this procedure until the oil from valve (6) is clean, then close valve (6) and fill the pump with fresh High Vacuum Pump Oil. Clean exhaust filter (4) in an oil solvent before it is again installed.Pump Motor Lubrication: After three years of normal or one year of heavy service, add a small amount of electric motor or SAE 10 oil to the motor bearings. DO NOT OVER OIL.Field Service Parts
Caterpillar parts catalog:
Parts ejector Caterpillar catalog:
2537493
EJECTOR AS
773D, 773E, 773F, 775B, 775D, 775E, 775F
773D, 773E, 773F, 775B, 775D, 775E, 775F
2856576
EJECTOR AS
770, 770G, 770G OEM, 772, 772G, 772G OEM
770, 770G, 770G OEM, 772, 772G, 772G OEM
2072832
EJECTOR AS
795F AC, 797, 797B, 797F
795F AC, 797, 797B, 797F
1754935
EJECTOR AS
795F AC, 795F XQ, 797, 797F
795F AC, 795F XQ, 797, 797F
1746228
EJECTOR AS
D400E II
D400E II
1746229
EJECTOR AS
D400E II
D400E II
2275875
EJECTOR AS
785C, 785D, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F-XQ
785C, 785D, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F-XQ
9D1557
EJECTOR
772, 773, 773B
772, 773, 773B
6D2143
EJECTOR
769
769
7D6587
EJECTOR
769, 769C
769, 769C
7D3637
EJECTOR
768B, 768C, 772, 773
768B, 768C, 772, 773
3720745
EJECTOR AS
773G, 773G LRC, 775G, 775G LRC
773G, 773G LRC, 775G, 775G LRC
3210047
EJECTOR AS
777D
777D