Illustration 1 g00633863
Schematic of the Modulating Valve for Forward (Number 2)
This diagnostic code is for the Modulating Valve for Forward (Number 2).See Systems Operation, "Solenoid Valves" for help with the identification of the locations of the solenoids.This diagnostic code is recorded when the current of the solenoid circuit is above normal. Note: Ensure that CID 0692 FMI 06 for the solenoid is on hold and that the diagnostic code indicator shows "SERV CODE". Test Step 1. CHECK THE SOLENOID AND THE INTERNAL HARNESS OF THE TRANSMISSION.
Turn the key start switch to the ON position.
Ensure that the diagnostic code for the solenoid is on hold.
Observe the status of the diagnostic code indicator.
At the transmission case, disconnect the machine harness from the internal harness for the transmission . Expected Result:"SERV CODE" is NOT showing when the internal harness for the transmission is disconnected. Results:
YES - "SERV CODE" is NOT showing when the internal harness for the transmission is disconnected. The circuit is correct. The solenoid or the internal harness for the transmission has failed. Proceed to Test Step 2.
NO - "SERV CODE" is showing when the internal harness for the transmission is disconnected. The diagnostic code remains. Proceed to Test Step 3.Test Step 2. CHECK THE RESISTANCE OF THE SOLENOID.
Within the transmission case, disconnect the internal harness for the transmission from the solenoid that is suspected.
At the solenoid, measure the resistance between the two contacts of the connector for the solenoid. Expected Result:The resistance should be greater than 5 ohms.Results:
OK - The resistance is greater than 5 ohms.Repair: The resistance of the solenoid is correct. The internal harness for the transmission is failed. In the internal harness for the transmission, the wire for the signal to the solenoid is shorted to the return circuit for the solenoid (wire 975-WH(White)) or to the frame ground. Repair the internal harness for the transmission or replace the internal harness for the transmission .STOP
NOT OK - The resistance is not greater than 5 ohms.Repair: The solenoid has failed. Replace the solenoid.STOPTest Step 3. CHECK THE SIGNAL CIRCUIT FOR THE SOLENOID FOR A SHORT TO GROUND.
At the transmission case, the machine harness remains disconnected from the internal harness for the transmission . Turn the key start switch to the OFF position.
Disconnect the machine harness from the solenoid.
Disconnect the machine harness connectors J1 and J2 from the ECM.
At machine harness connector J1 or J2, measure the resistance from the solenoid signal contact to all possible sources of ground. The possible ground sources are contact J1-2, contact J1-5, contact J1-7, contact J1-15, contact J1-16, contact J2-3 and frame ground. Expected Result:Each resistance should be greater than 5000 ohms.Results:
OK - Each resistance is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 4.
NOT OK - Each resistance is not greater than 5000 ohms.Repair: There is a short in the machine harness. The short is between the wire for the signal to the solenoid and the circuit that has a low resistance
Caterpillar parts catalog:
Parts ejector Caterpillar catalog:
3210047
EJECTOR AS
777D
777D
3357994
EJECTOR AS
773E, 773F, 775F
773E, 773F, 775F
2856576
EJECTOR AS
770, 770G, 770G OEM, 772, 772G, 772G OEM
770, 770G, 770G OEM, 772, 772G, 772G OEM
2072832
EJECTOR AS
795F AC, 797, 797B, 797F
795F AC, 797, 797B, 797F
1754935
EJECTOR AS
795F AC, 795F XQ, 797, 797F
795F AC, 795F XQ, 797, 797F
1746228
EJECTOR AS
D400E II
D400E II
9D5007
EJECTOR
777
777
9D1557
EJECTOR
772, 773, 773B
772, 773, 773B
6D2143
EJECTOR
769
769
7D6587
EJECTOR
769, 769C
769, 769C
7D3637
EJECTOR
768B, 768C, 772, 773
768B, 768C, 772, 773