Information:
code means that the ECM has determined that the current of the relay circuit is below normal.The possible causes of the diagnostic code are listed below:
The energize circuit of the relay is open.
The controller harness has a broken wire.
The ECM has failed. This situation is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 5013 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The machine response is listed below:
The "Lift" Relays may not turn ON.
Machine performance may not lift material properly if material is lifted at all.Note: Before performing this procedure, verify that all circuit breakers and fuses in the charging circuit and the ECM system supply circuit are closed. If a problem with a circuit breaker or a fuse is found, correct the problem. Verify that this diagnostic code is active before performing this procedure.Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE
Turn the disconnect switch and the key start switch to the OFF position.
Inspect the harness connectors. Clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Use the Cat Electronic Technician (ET) service tool to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect intermittent shorts or opens in the machine wiring harness.
Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that the clips for each connector are fastened securely.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the SPN 5013 FMI 05 diagnostic code is still active.Expected Result:The SPN 5013 FMI 05 diagnostic code is still active.Results:
YES - The SPN 5013 FMI 05 diagnostic code remains active. Proceed to Test Step 2.
NO - The SPN 5013 FMI 05 code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors. Resume normal machine operation.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the J2 connector at the ECM.
Place a jumper from J2-6 (wire G890-PU) and J2-8 (wire 299-BK).
Disconnect wire 299-BK from terminal 4 for the "Lift" Relay (Solid State Relay 170).
Disconnect the wire (G890-PU) from terminal 3 for "Lift" Relay (SSR 170).
At the "Lift" Relay (SSR 170), measure the resistance between wire (G890-PU) and wire (299-BK).Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The harness has continuity in the circuit. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5 ohms.Repair: The harness has failed.
The energize circuit of the relay is open.
The controller harness has a broken wire.
The ECM has failed. This situation is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 5013 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The machine response is listed below:
The "Lift" Relays may not turn ON.
Machine performance may not lift material properly if material is lifted at all.Note: Before performing this procedure, verify that all circuit breakers and fuses in the charging circuit and the ECM system supply circuit are closed. If a problem with a circuit breaker or a fuse is found, correct the problem. Verify that this diagnostic code is active before performing this procedure.Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE
Turn the disconnect switch and the key start switch to the OFF position.
Inspect the harness connectors. Clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Use the Cat Electronic Technician (ET) service tool to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect intermittent shorts or opens in the machine wiring harness.
Reconnect all harness connectors. Make sure that the connectors are fully seated. Observe that the clips for each connector are fastened securely.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the SPN 5013 FMI 05 diagnostic code is still active.Expected Result:The SPN 5013 FMI 05 diagnostic code is still active.Results:
YES - The SPN 5013 FMI 05 diagnostic code remains active. Proceed to Test Step 2.
NO - The SPN 5013 FMI 05 code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors. Resume normal machine operation.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the J2 connector at the ECM.
Place a jumper from J2-6 (wire G890-PU) and J2-8 (wire 299-BK).
Disconnect wire 299-BK from terminal 4 for the "Lift" Relay (Solid State Relay 170).
Disconnect the wire (G890-PU) from terminal 3 for "Lift" Relay (SSR 170).
At the "Lift" Relay (SSR 170), measure the resistance between wire (G890-PU) and wire (299-BK).Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The harness has continuity in the circuit. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5 ohms.Repair: The harness has failed.
Caterpillar parts catalog:
Parts elbow Caterpillar catalog:
4V2420
ELBOW
824C, 826C
824C, 826C
1W6056
ELBOW-WATER
D8L, D9N
D8L, D9N
5P9372
ELBOW
814B, 815B, 824C
814B, 815B, 824C
6P7013
ELBOW
D9H
D9H
7T0750
ELBOW
844, 844H, 854G, D10, D11N, D11R, D11T
844, 844H, 854G, D10, D11N, D11R, D11T
1854471
ELBOW
D11R
D11R
6T0258
ELBOW
D11N, D11R, D11T
D11N, D11R, D11T
1236922
ELBOW
D11N, D11R
D11N, D11R
2W1041
ELBOW
D11N
D11N
4W4216
ELBOW
D11N, D11R
D11N, D11R
7W3540
ELBOW
D11N, D11R
D11N, D11R
7W3536
ELBOW
D11N, D11R
D11N, D11R